root@observium:/opt/observium# ./poller.php -h 906 -m sensors -d DEBUG! CMD[/usr/bin/svn info /opt/observium] CMD EXITCODE[0] CMD RUNTIME[0.0078s] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: http://svn.observium.org/svn/observium/trunk Relative URL: ^/observium/trunk Repository Root: http://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 9417 Node Kind: directory Schedule: normal Last Changed Author: adama Last Changed Rev: 9417 Last Changed Date: 2018-09-02 18:32:22 +0200 (Sun, 02 Sep 2018) ] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';] SQL RUNTIME[0.00025105s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00013113s] SQL[SET SESSION `sql_mode` = 'NO_ZERO_IN_DATE,NO_ZERO_DATE,ERROR_FOR_DIVISION_BY_ZERO,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION'] SQL RUNTIME[0.00007915s] DB mode(s) disabled: STRICT_TRANS_TABLES, ONLY_FULL_GROUP_BY SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';] SQL RUNTIME[0.00014710s] SQL[SELECT * FROM `config`] SQL RUNTIME[0.00022697s] ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 18.9.9417 http://www.observium.org SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver';] SQL RUNTIME[0.00015283s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] SQL RUNTIME[0.00014210s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date';] SQL RUNTIME[0.00014496s] CMD[/opt/observium/scripts/distro] CMD EXITCODE[0] CMD RUNTIME[0.054s] STDOUT[ Linux|4.4.0-127-generic|amd64|Ubuntu|16.04|qemu| ] CMD[/usr/bin/env python --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0025s] STDOUT[ Python 2.7.12 ] SQL[SELECT version();] SQL RUNTIME[0.00027490s] CMD[/usr/bin/snmpget --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0023s] STDOUT[ NET-SNMP version: 5.7.3 ] CMD[/usr/bin/rrdtool --version | head -n1] CMD EXITCODE[0] CMD RUNTIME[0.0096s] STDOUT[ RRDtool 1.5.5 Copyright by Tobias Oetiker ] CMD[/usr/bin/rrdcached -h | head -n1] CMD EXITCODE[0] CMD RUNTIME[0.0083s] STDOUT[ RRDCacheD 1.5.5 ] CMD[/usr/bin/fping -v 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0019s] STDOUT[ /usr/bin/fping: Version 3.13 /usr/bin/fping: comments to david@schweikert.ch ] CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}'] CMD EXITCODE[0] CMD RUNTIME[0.039s] STDOUT[ Apache/2.4.18 ] CMD[date "+%:z"] CMD EXITCODE[0] CMD RUNTIME[0.0033s] CMD EXITDELAY[10ms] STDOUT[ +02:00 ] SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00022316s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00016499s] SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.25505590s] ##### Software versions ##### o OS Linux 4.4.0-127-generic [amd64] (Ubuntu 16.04) o Apache 2.4.18 o PHP 7.0.30-0ubuntu0.16.04.1 (OPcache: ENABLED) o Python 2.7.12 o MySQL 5.7.23-0ubuntu0.16.04.1 (extension: mysqli 5.0.12-dev) o SNMP NET-SNMP 5.7.3 o RRDtool 1.5.5 (rrdcached 1.5.5: unix:/var/run/rrdcached.sock) o Fping 3.13 (IPv4 and IPv6) ##### Memory Limit ##### o PHP Unlimited ##### MySQL mode ##### o MySQL NO_ZERO_IN_DATE,NO_ZERO_DATE,ERROR_FOR_DIVISION_BY_ZERO,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION ##### Charset info ##### o PHP UTF-8 o MySQL utf8 ##### Timezones info ##### o Date Wednesday, 05-Sep-18 09:00:33 CEST o PHP +02:00 o MySQL +02:00 SQL[SELECT * FROM `alerts_maint` WHERE `maint_start` < '1536130833' AND `maint_end` > '1536130833'] SQL RUNTIME[0.00040603s] ##### Starting polling run at 2018-09-05 09:00:33 ##### SQL[SELECT `device_id` FROM `devices` WHERE `disabled` = 0 AND `device_id` = '906' ORDER BY `device_id` ASC] SQL RUNTIME[0.00026298s] SQL[SELECT * FROM `devices` WHERE `device_id` = '906'] SQL RUNTIME[0.00032902s] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '906'] SQL RUNTIME[0.00026798s] SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'poller.php' AND `device_id` = '906'] SQL RUNTIME[0.00021005s] SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('32429','poller.php','19302','0','php ./poller.php -h 906 -m sensors -d','1536130833','906')] SQL RUNTIME[0.01323199s] SQL[SELECT * FROM `alert_tests` WHERE 1] SQL RUNTIME[0.00060511s] Cached 58 alert rules. SQL[SELECT * FROM `alert_table` WHERE `device_id` = '906'] SQL RUNTIME[0.00054908s] ##### extreme-device [906] ##### o OS xos o OS Group extremeware o Last poll duration 0.42 seconds o Last Polled 2018-09-05 08:59:50 o SNMP Version v2c CMD[/usr/bin/fping -t 500 -c 1 -q 10.129.96.100 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0028s] STDOUT[ 10.129.96.100 : xmt/rcv/%loss = 1/1/0%, min/avg/max = 0.62/0.62/0.62 ] CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pu -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'extreme-device':'161' sysObjectID.0 sysUpTime.0] CMD EXITCODE[0] CMD RUNTIME[0.0117s] STDOUT[ sysObjectID.0 = enterprises.1916.2.227 sysUpTime.0 = 97:23:00:35.00 ] SNMP STATUS[TRUE] o Device status Device is reachable by PING (0.62ms) and SNMP (11.67ms) RRD /opt/observium/rrd/extreme-device/status.rrd already exists - no need to create. RRD CMD[update extreme-device/status.rrd N:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.03] RRD_STATUS[TRUE] RRD /opt/observium/rrd/extreme-device/ping.rrd already exists - no need to create. RRD CMD[update extreme-device/ping.rrd N:0.62 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.03] RRD_STATUS[TRUE] RRD /opt/observium/rrd/extreme-device/ping_snmp.rrd already exists - no need to create. RRD CMD[update extreme-device/ping_snmp.rrd N:11.67 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.03] RRD_STATUS[TRUE] SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '906'] SQL RUNTIME[0.00042701s] o Modules Enabled system, os, sensors including: includes/polling/system.inc.php ##### Module Start: system ##### SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '906' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00028300s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '906' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00016189s] SQL[SELECT * FROM `observium_attribs`] SQL RUNTIME[0.00019002s] o SNMPv2-MIB CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pu -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'extreme-device':'161' sysUpTime.0 sysLocation.0 sysContact.0 sysName.0] CMD EXITCODE[0] CMD RUNTIME[0.0125s] STDOUT[ sysUpTime.0 = 97:23:00:35.00 sysLocation.0 = RZ Buchenweg TK-Raum sysContact.0 = support@extremenetworks.com, +1 888 257 3000 sysName.0 = X440G2-12p-10G4 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pu -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'extreme-device':'161' sysDescr.0] CMD EXITCODE[0] CMD RUNTIME[0.0103s] STDOUT[ ExtremeXOS (X440G2-12p-10G4) version 22.3.1.4 22.3.1.4-patch1-7 by release-manager on Tue Jan 16 09:29:17 EST 2018 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pu -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'extreme-device':'161' sysObjectID.0] CMD EXITCODE[0] CMD RUNTIME[0.0092s] STDOUT[ .1.3.6.1.4.1.1916.2.227 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pu -OQUv -m SNMP-FRAMEWORK-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'extreme-device':'161' snmpEngineID.0] CMD EXITCODE[0] CMD RUNTIME[0.0072s] STDOUT[ "80 00 07 7C 03 00 04 96 9B 54 4F " ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pu -OQUv -m SNMP-FRAMEWORK-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'extreme-device':'161' snmpEngineTime.0] CMD EXITCODE[0] CMD RUNTIME[0.007s] STDOUT[ 8459939 ] SNMP STATUS[TRUE] Using SNMP Agent sysUpTime (8463635 sec. => 97 days, 23h 35s) RRD /opt/observium/rrd/extreme-device/uptime.rrd already exists - no need to create. RRD CMD[update extreme-device/uptime.rrd N:8463635 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.09] RRD_STATUS[TRUE] o Uptime 97 days, 23h 35s o Last reboot 2018-05-30 10:56:13 /opt/observium/includes/polling/system.inc.php:282 array( [use] => string(9) "sysUpTime" [sysUpTime] => int(8463635) [snmpEngineTime] => int(8459939) [uptime] => int(8463635) [formatted] => string(16) "97 days, 23h 35s" [message] => string(26) "Using SNMP Agent sysUpTime" [previous] => string(7) "8463590" [diff] => int(-45) [last_rebooted] => string(10) "1527670573" [rebooted] => int(0) ) CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pu -OQUsn -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'extreme-device':'161' .1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3] CMD EXITCODE[0] CMD RUNTIME[0.0094s] STDOUT[ .1.3.6.1.4.1.2021.10.1.5.1 = No Such Object available on this agent at this OID .1.3.6.1.4.1.2021.10.1.5.2 = No Such Object available on this agent at this OID .1.3.6.1.4.1.2021.10.1.5.3 = No Such Object available on this agent at this OID ] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '906' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'UCD-SNMP-MIB' AND `oid` = '.1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3';] SQL RUNTIME[0.00054288s] SQL[UPDATE `snmp_errors` set `error_count` ='24724',`updated` ='1536130834' WHERE `error_id` = '47238'] SQL RUNTIME[0.01915002s] SNMP STATUS[FALSE] o sysObjectID .1.3.6.1.4.1.1916.2.227 o snmpEngineID 8000077C030004969B544F o sysDescr ExtremeXOS (X440G2-12p-10G4) version 22.3.1.4 22.3.1.4-patch1-7 by release-manager on Tue Jan 16 09:29:17 EST 2018 o sysName X440G2-12p-10G4 o Location RZ Buchenweg TK-Raum SQL[SELECT * FROM `devices_locations` WHERE `device_id` = '906'] SQL RUNTIME[0.00040913s] o Module time 0.0917s including: includes/polling/os.inc.php ##### Module Start: os ##### Added OS param from sysDescr parse: 'version' = '22.3.1.4' Added OS param from sysDescr parse: 'hardware' = 'X440G2-12p-10G4' CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pu -Oqv -m EXTREME-SYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/extreme 'udp':'extreme-device':'161' extremeSystemID.0] CMD EXITCODE[0] CMD RUNTIME[0.0117s] STDOUT[ "800614-00-06 1623N-40701" ] SNMP STATUS[TRUE] Added OS param from SNMP definition walk: 'serial' = '800614-00-06 1623N-40701' o OS Poller OS CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pu -OQUs -m EXTREME-SYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/extreme 'udp':'extreme-device':'161' extremeImageBooted.0 extremePrimarySoftwareRev.0 extremeSecondarySoftwareRev.0 extremeImageSshCapability.cur extremeImageUAACapability.cur] CMD EXITCODE[0] CMD RUNTIME[0.0189s] STDOUT[ extremeImageBooted.0 = secondary extremePrimarySoftwareRev.0 = "21.1.1.4 patch1-2" extremeSecondarySoftwareRev.0 = "22.3.1.4 patch1-7" extremeImageSshCapability.cur = ssh extremeImageUAACapability.cur = unknown ] SNMP STATUS[TRUE] Redded OS param from sysDescr parse or SNMP definition walk: 'hardware' = 'X440G2-12p-10G4' o Hardware X440G2-12p-10G4 o Version 22.3.1.4 patch1-7 o Features ssh o Serial 800614-00-06 1623N-40701 o Asset o Module time 0.0348s including: includes/polling/sensors.inc.php ##### Module Start: sensors ##### SQL[SELECT DISTINCT `sensor_class` FROM `sensors` WHERE `device_id` = '906' AND `sensor_deleted` = '0' AND `sensor_class` IN ('temperature','humidity','fanspeed','dewpoint','airflow','voltage','current','charge','power','energy','apower','rpower','crestfactor','powerfactor','impedance','resistance','frequency','dbm','snr','dust','sound','capacity','load','runtime','volume','waterflow','pressure','velocity','illuminance','wavelength','counter')] SQL RUNTIME[0.00149488s] SQL[SELECT * FROM `entity_attribs` WHERE `device_id` = '906' AND `entity_type` IN ('sensor')] SQL RUNTIME[0.00024295s] SQL[SELECT `sensor_oid` FROM `sensors` WHERE `device_id` = '906' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00033092s] CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pu -OQUsn -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'extreme-device':'161' .1.3.6.1.2.1.99.1.1.1.4.272 .1.3.6.1.2.1.99.1.1.1.4.273 .1.3.6.1.2.1.99.1.1.1.4.274 .1.3.6.1.2.1.99.1.1.1.4.275 .1.3.6.1.2.1.99.1.1.1.4.276 .1.3.6.1.2.1.105.1.3.1.1.4.1 .1.3.6.1.4.1.1916.1.1.1.8.0 .1.3.6.1.4.1.1916.1.1.1.9.1.4.101 .1.3.6.1.4.1.1916.1.1.1.9.1.4.102] CMD EXITCODE[0] CMD RUNTIME[0.0845s] STDOUT[ .1.3.6.1.2.1.99.1.1.1.4.272 = 30 .1.3.6.1.2.1.99.1.1.1.4.273 = 3 .1.3.6.1.2.1.99.1.1.1.4.274 = 16 .1.3.6.1.2.1.99.1.1.1.4.275 = -6 .1.3.6.1.2.1.99.1.1.1.4.276 = -7 .1.3.6.1.2.1.105.1.3.1.1.4.1 = 0 .1.3.6.1.4.1.1916.1.1.1.8.0 = 68 .1.3.6.1.4.1.1916.1.1.1.9.1.4.101 = 0 .1.3.6.1.4.1.1916.1.1.1.9.1.4.102 = 0 ] SNMP STATUS[TRUE] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'power' AND `device_id` = '906' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00067902s] Checking (snmp) power PoE Group 1 /opt/observium/includes/polling/functions.inc.php:72 array( [sensor_id] => string(5) "22840" [sensor_deleted] => string(1) "0" [sensor_class] => string(5) "power" [device_id] => string(3) "906" [poller_type] => string(4) "snmp" [sensor_oid] => string(28) ".1.3.6.1.2.1.105.1.3.1.1.4.1" [sensor_mib] => null [sensor_object] => null [sensor_index] => string(29) "pethMainPseConsumptionPower.1" [sensor_type] => string(18) "power-ethernet-mib" [sensor_descr] => string(11) "PoE Group 1" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(3) "200" [sensor_limit_warn] => string(3) "140" [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(7) "0.00000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1536130789" [sensor_last_change] => string(10) "1528715759" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:167 array( [sensor_value] => int(0) ) RRD /opt/observium/rrd/extreme-device/sensor-power-power-ethernet-mib-pethMainPseConsumptionPower.1.rrd already exists - no need to create. RRD CMD[update extreme-device/sensor-power-power-ethernet-mib-pethMainPseConsumptionPower.1.rrd N:0 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.26] RRD_STATUS[TRUE] SQL[UPDATE `sensors` set `sensor_value` ='0',`sensor_event` ='ok',`sensor_status` ='',`sensor_last_change` ='1528715759',`sensor_polled` ='1536130834' WHERE `sensor_id` = '22840'] SQL RUNTIME[0.04480910s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '906' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00046682s] Checking (snmp) fanspeed Fan 101 /opt/observium/includes/polling/functions.inc.php:72 array( [sensor_id] => string(5) "22841" [sensor_deleted] => string(1) "0" [sensor_class] => string(8) "fanspeed" [device_id] => string(3) "906" [poller_type] => string(4) "snmp" [sensor_oid] => string(33) ".1.3.6.1.4.1.1916.1.1.1.9.1.4.101" [sensor_mib] => null [sensor_object] => null [sensor_index] => string(3) "101" [sensor_type] => string(34) "EXTREME-SYSTEM-MIB-extremeFanSpeed" [sensor_descr] => string(7) "Fan 101" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(5) "15000" [sensor_limit_warn] => string(5) "16000" [sensor_limit_low] => string(2) "-2" [sensor_limit_low_warn] => string(2) "-1" [sensor_custom_limit] => string(1) "1" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(7) "0.00000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1536130789" [sensor_last_change] => string(10) "1531396670" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:167 array( [sensor_value] => int(0) ) RRD /opt/observium/rrd/extreme-device/sensor-fanspeed-EXTREME-SYSTEM-MIB-extremeFanSpeed-101.rrd already exists - no need to create. RRD CMD[update extreme-device/sensor-fanspeed-EXTREME-SYSTEM-MIB-extremeFanSpeed-101.rrd N:0 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.30] RRD_STATUS[TRUE] SQL[UPDATE `sensors` set `sensor_value` ='0',`sensor_event` ='ok',`sensor_status` ='',`sensor_last_change` ='1531396670',`sensor_polled` ='1536130834' WHERE `sensor_id` = '22841'] SQL RUNTIME[0.03037596s] Checking (snmp) fanspeed Fan 102 /opt/observium/includes/polling/functions.inc.php:72 array( [sensor_id] => string(5) "22842" [sensor_deleted] => string(1) "0" [sensor_class] => string(8) "fanspeed" [device_id] => string(3) "906" [poller_type] => string(4) "snmp" [sensor_oid] => string(33) ".1.3.6.1.4.1.1916.1.1.1.9.1.4.102" [sensor_mib] => null [sensor_object] => null [sensor_index] => string(3) "102" [sensor_type] => string(34) "EXTREME-SYSTEM-MIB-extremeFanSpeed" [sensor_descr] => string(7) "Fan 102" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(5) "15000" [sensor_limit_warn] => string(5) "16000" [sensor_limit_low] => string(2) "-2" [sensor_limit_low_warn] => string(2) "-1" [sensor_custom_limit] => string(1) "1" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(7) "0.00000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1536130789" [sensor_last_change] => string(10) "1531396670" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:167 array( [sensor_value] => int(0) ) RRD /opt/observium/rrd/extreme-device/sensor-fanspeed-EXTREME-SYSTEM-MIB-extremeFanSpeed-102.rrd already exists - no need to create. RRD CMD[update extreme-device/sensor-fanspeed-EXTREME-SYSTEM-MIB-extremeFanSpeed-102.rrd N:0 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0012s] RRD STDOUT[OK u:0.00 s:0.00 r:0.34] RRD_STATUS[TRUE] SQL[UPDATE `sensors` set `sensor_value` ='0',`sensor_event` ='ok',`sensor_status` ='',`sensor_last_change` ='1531396670',`sensor_polled` ='1536130834' WHERE `sensor_id` = '22842'] SQL RUNTIME[0.02600193s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '906' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00055718s] Checking (snmp) temperature SFP Temperature /opt/observium/includes/polling/functions.inc.php:72 array( [sensor_id] => string(5) "22843" [sensor_deleted] => string(1) "0" [sensor_class] => string(11) "temperature" [device_id] => string(3) "906" [poller_type] => string(4) "snmp" [sensor_oid] => string(27) ".1.3.6.1.2.1.99.1.1.1.4.272" [sensor_mib] => null [sensor_object] => null [sensor_index] => string(3) "272" [sensor_type] => string(13) "entity-sensor" [sensor_descr] => string(15) "SFP Temperature" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(2) "48" [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => string(4) "1015" [measured_class] => string(4) "port" [measured_entity] => string(5) "54014" [entPhysicalIndex] => string(3) "272" [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(8) "30.00000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1536130789" [sensor_last_change] => string(10) "1528715759" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:167 array( [sensor_value] => int(30) ) RRD /opt/observium/rrd/extreme-device/sensor-temperature-entity-sensor-272.rrd already exists - no need to create. RRD CMD[update extreme-device/sensor-temperature-entity-sensor-272.rrd N:30 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.37] RRD_STATUS[TRUE] SQL[UPDATE `sensors` set `sensor_value` ='30',`sensor_event` ='ok',`sensor_status` ='',`sensor_last_change` ='1528715759',`sensor_polled` ='1536130834' WHERE `sensor_id` = '22843'] SQL RUNTIME[0.02209592s] Checking (snmp) temperature System Temperature /opt/observium/includes/polling/functions.inc.php:72 array( [sensor_id] => string(5) "22848" [sensor_deleted] => string(1) "0" [sensor_class] => string(11) "temperature" [device_id] => string(3) "906" [poller_type] => string(4) "snmp" [sensor_oid] => string(27) ".1.3.6.1.4.1.1916.1.1.1.8.0" [sensor_mib] => null [sensor_object] => null [sensor_index] => string(1) "0" [sensor_type] => string(44) "EXTREME-SYSTEM-MIB-extremeCurrentTemperature" [sensor_descr] => string(18) "System Temperature" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(5) "108.8" [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(8) "68.00000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1536130789" [sensor_last_change] => string(10) "1528715759" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:167 array( [sensor_value] => int(68) ) RRD /opt/observium/rrd/extreme-device/sensor-temperature-EXTREME-SYSTEM-MIB-extremeCurrentTemperature-0.rrd already exists - no need to create. RRD CMD[update extreme-device/sensor-temperature-EXTREME-SYSTEM-MIB-extremeCurrentTemperature-0.rrd N:68 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.39] RRD_STATUS[TRUE] SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":68}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1536130834',`last_ok` ='1536130834' WHERE `alert_table_id` = '110612'] SQL RUNTIME[0.02784705s] RRD /opt/observium/rrd/extreme-device/alert-110612.rrd already exists - no need to create. RRD CMD[update extreme-device/alert-110612.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0012s] RRD STDOUT[OK u:0.00 s:0.00 r:0.42] RRD_STATUS[TRUE] SQL[UPDATE `sensors` set `sensor_value` ='68',`sensor_event` ='ok',`sensor_status` ='',`sensor_last_change` ='1528715759',`sensor_polled` ='1536130834' WHERE `sensor_id` = '22848'] SQL RUNTIME[0.04213715s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '906' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00052810s] Checking (snmp) voltage SFP VCC Voltage /opt/observium/includes/polling/functions.inc.php:72 array( [sensor_id] => string(5) "22844" [sensor_deleted] => string(1) "0" [sensor_class] => string(7) "voltage" [device_id] => string(3) "906" [poller_type] => string(4) "snmp" [sensor_oid] => string(27) ".1.3.6.1.2.1.99.1.1.1.4.273" [sensor_mib] => null [sensor_object] => null [sensor_index] => string(3) "273" [sensor_type] => string(13) "entity-sensor" [sensor_descr] => string(15) "SFP VCC Voltage" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(4) "3.45" [sensor_limit_warn] => null [sensor_limit_low] => string(4) "2.55" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => string(4) "1015" [measured_class] => string(4) "port" [measured_entity] => string(5) "54014" [entPhysicalIndex] => string(3) "273" [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(7) "3.00000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1536130789" [sensor_last_change] => string(10) "1528715759" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:167 array( [sensor_value] => int(3) ) RRD /opt/observium/rrd/extreme-device/sensor-voltage-entity-sensor-273.rrd already exists - no need to create. RRD CMD[update extreme-device/sensor-voltage-entity-sensor-273.rrd N:3 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.47] RRD_STATUS[TRUE] SQL[UPDATE `sensors` set `sensor_value` ='3',`sensor_event` ='ok',`sensor_status` ='',`sensor_last_change` ='1528715759',`sensor_polled` ='1536130834' WHERE `sensor_id` = '22844'] SQL RUNTIME[0.03226495s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '906' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00054002s] Checking (snmp) current SFP TX Bias Current /opt/observium/includes/polling/functions.inc.php:72 array( [sensor_id] => string(5) "22845" [sensor_deleted] => string(1) "0" [sensor_class] => string(7) "current" [device_id] => string(3) "906" [poller_type] => string(4) "snmp" [sensor_oid] => string(27) ".1.3.6.1.2.1.99.1.1.1.4.274" [sensor_mib] => null [sensor_object] => null [sensor_index] => string(3) "274" [sensor_type] => string(13) "entity-sensor" [sensor_descr] => string(19) "SFP TX Bias Current" [sensor_unit] => null [sensor_multiplier] => string(5) "0.001" [sensor_limit] => string(5) "0.024" [sensor_limit_warn] => null [sensor_limit_low] => null [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => string(4) "1015" [measured_class] => string(4) "port" [measured_entity] => string(5) "54014" [entPhysicalIndex] => string(3) "274" [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(7) "0.01600" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1536130789" [sensor_last_change] => string(10) "1528715759" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:167 array( [sensor_value] => int(16) ) RRD /opt/observium/rrd/extreme-device/sensor-current-entity-sensor-274.rrd already exists - no need to create. RRD CMD[update extreme-device/sensor-current-entity-sensor-274.rrd N:0.016 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.50] RRD_STATUS[TRUE] SQL[UPDATE `sensors` set `sensor_value` ='0.016',`sensor_event` ='ok',`sensor_status` ='',`sensor_last_change` ='1528715759',`sensor_polled` ='1536130834' WHERE `sensor_id` = '22845'] SQL RUNTIME[0.05285978s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '906' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00043607s] Checking (snmp) dbm SFP TX Power /opt/observium/includes/polling/functions.inc.php:72 array( [sensor_id] => string(5) "23675" [sensor_deleted] => string(1) "0" [sensor_class] => string(3) "dbm" [device_id] => string(3) "906" [poller_type] => string(4) "snmp" [sensor_oid] => string(27) ".1.3.6.1.2.1.99.1.1.1.4.275" [sensor_mib] => null [sensor_object] => null [sensor_index] => string(3) "275" [sensor_type] => string(13) "entity-sensor" [sensor_descr] => string(12) "SFP TX Power" [sensor_unit] => string(1) "W" [sensor_multiplier] => string(8) "0.000001" [sensor_limit] => null [sensor_limit_warn] => null [sensor_limit_low] => null [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => string(4) "1015" [measured_class] => string(4) "port" [measured_entity] => string(5) "54014" [entPhysicalIndex] => string(3) "275" [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(7) "0.00000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1536130789" [sensor_last_change] => string(10) "1534272756" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:167 array( [sensor_value] => int(-6) ) Converted DBM value: -6.0E-6 W -> FALSE RRD /opt/observium/rrd/extreme-device/sensor-dbm-entity-sensor-275.rrd already exists - no need to create. RRD CMD[update extreme-device/sensor-dbm-entity-sensor-275.rrd N: --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.56] RRD_STATUS[TRUE] SQL[UPDATE `sensors` set `sensor_value` ='',`sensor_event` ='ok',`sensor_status` ='',`sensor_last_change` ='1534272756',`sensor_polled` ='1536130834' WHERE `sensor_id` = '23675'] SQL RUNTIME[0.02343702s] Checking (snmp) dbm SFP RX Power /opt/observium/includes/polling/functions.inc.php:72 array( [sensor_id] => string(5) "23676" [sensor_deleted] => string(1) "0" [sensor_class] => string(3) "dbm" [device_id] => string(3) "906" [poller_type] => string(4) "snmp" [sensor_oid] => string(27) ".1.3.6.1.2.1.99.1.1.1.4.276" [sensor_mib] => null [sensor_object] => null [sensor_index] => string(3) "276" [sensor_type] => string(13) "entity-sensor" [sensor_descr] => string(12) "SFP RX Power" [sensor_unit] => string(1) "W" [sensor_multiplier] => string(8) "0.000001" [sensor_limit] => null [sensor_limit_warn] => null [sensor_limit_low] => null [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => string(4) "1015" [measured_class] => string(4) "port" [measured_entity] => string(5) "54014" [entPhysicalIndex] => string(3) "276" [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(7) "0.00000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1536130789" [sensor_last_change] => string(10) "1534272756" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:167 array( [sensor_value] => int(-7) ) Converted DBM value: -7.0E-6 W -> FALSE RRD /opt/observium/rrd/extreme-device/sensor-dbm-entity-sensor-276.rrd already exists - no need to create. RRD CMD[update extreme-device/sensor-dbm-entity-sensor-276.rrd N: --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.58] RRD_STATUS[TRUE] SQL[UPDATE `sensors` set `sensor_value` ='',`sensor_event` ='ok',`sensor_status` ='',`sensor_last_change` ='1534272756',`sensor_polled` ='1536130834' WHERE `sensor_id` = '23676'] SQL RUNTIME[0.02429390s] +---------------------+-------------+----------------------------------------------+--------+----------+-------+---------------------+ | Descr | Class | Type | Origin | Value | Event | Last Changed | +---------------------+-------------+----------------------------------------------+--------+----------+-------+---------------------+ | PoE Group 1 | power | power-ethernet-mib | snmp | 0W | ok | 2018-06-11 13:15:59 | | Fan 101 | fanspeed | EXTREME-SYSTEM-MIB-extremeFanSpeed | snmp | 0RPM | ok | 2018-07-12 13:57:50 | | Fan 102 | fanspeed | EXTREME-SYSTEM-MIB-extremeFanSpeed | snmp | 0RPM | ok | 2018-07-12 13:57:50 | | SFP Temperature | temperature | entity-sensor | snmp | 30°C | ok | 2018-06-11 13:15:59 | | System Temperature | temperature | EXTREME-SYSTEM-MIB-extremeCurrentTemperature | snmp | 68°C | ok | 2018-06-11 13:15:59 | | SFP VCC Voltage | voltage | entity-sensor | snmp | 3V | ok | 2018-06-11 13:15:59 | | SFP TX Bias Current | current | entity-sensor | snmp | 0.016A | ok | 2018-06-11 13:15:59 | | SFP TX Power | dbm | entity-sensor | snmp | dBm | ok | 2018-08-14 20:52:36 | | SFP RX Power | dbm | entity-sensor | snmp | dBm | ok | 2018-08-14 20:52:36 | +---------------------+-------------+----------------------------------------------+--------+----------+-------+---------------------+ o Module time 0.4820s ##### extreme-device [906] completed poller modules at 2018-09-05 09:00:34 ##### o Graphs [checked] availability, ping, ping_snmp, uptime, power, fanspeed, temperature, voltage, current, dbm o Poller time 0.6502 seconds Updating extreme-device - > $update_array /opt/observium/includes/polling/functions.inc.php:812 array( [uptime] => int(8463635) [last_polled] => array( [0] => string(5) "NOW()" ) [last_polled_timetaken] => double(0.6502) ) SQL[UPDATE `devices` set `uptime` ='8463635',`last_polled` =NOW(),`last_polled_timetaken` ='0.6502' WHERE `device_id` = '906'] SQL RUNTIME[0.01386595s] o Updated Data uptime, last_polled, last_polled_timetaken SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"device_status\":\"1\"}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1536130834',`last_ok` ='1536130834' WHERE `alert_table_id` = '110614'] SQL RUNTIME[0.03331900s] RRD /opt/observium/rrd/extreme-device/alert-110614.rrd already exists - no need to create. RRD CMD[update extreme-device/alert-110614.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.69] RRD_STATUS[TRUE] SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '32429' AND `process_name` = 'poller.php' AND `device_id` = '906'] SQL RUNTIME[0.03611302s] ./poller.php: extreme-device - 1 devices polled in 1.140 secs ##### Completed polling run at 2018-09-05 09:00:34 ##### NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output. o Devices Polled 1 o Poller Time 1.140 secs o Memory usage 4MB (peak: 4MB) o MySQL Usage Insert[1/0.014s] Update[13/0.395s] Delete[1/0.036s] Cell[4/0.001s] Row[10/0.004s] Rows[19/0.267s] Col[2/0.002s] (0.72s63.143%) o RRDTool Usage update[15/0.017s] (0.017s 1.48%) o SNMP Usage snmpget[10/0.182s] (0.182s 16.006%) root@observium:/opt/observium# root@observium:/opt/observium# snmpwalk -v 2c -c ultrasecret extreme-device .1.3.6.1.2.1.99.1.1.1.4.275 iso.3.6.1.2.1.99.1.1.1.4.275 = INTEGER: -6 root@observium:/opt/observium# snmpwalk -v 2c -c ultrasecret extreme-device .1.3.6.1.2.1.99.1.1.1.4.276 iso.3.6.1.2.1.99.1.1.1.4.276 = INTEGER: -7 root@observium:/opt/observium#