DEBUG! [1;37mLoad class 'Console_Color2' from '/opt/observium/libs/pear/Console/Color2.php': [0;32mOK[0m CMD[[0;33m/usr/bin/svn info /opt/observium[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0082s[0m][0m STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: http://svn.observium.org/svn/observium/trunk Relative URL: ^/observium/trunk Repository Root: http://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 9229 Node Kind: directory Schedule: normal Last Changed Author: mike Last Changed Rev: 9229 Last Changed Date: 2018-05-14 15:54:24 +0000 (Mon, 14 May 2018) ][0m SQL[[0;33mSELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00092506s[0m][0m SQL[[0;33mSELECT @@SESSION.sql_mode;[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00071788s[0m][0m SQL[[0;33mSET SESSION `sql_mode` = 'NO_ZERO_IN_DATE,NO_ZERO_DATE,ERROR_FOR_DIVISION_BY_ZERO,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00095606s[0m][0m DB mode(s) disabled: STRICT_TRANS_TABLES, ONLY_FULL_GROUP_BY SQL[[0;33mSELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00073195s[0m][0m SQL[[0;33mSELECT * FROM `config`[0m][0m ROWS[[0;32m13[0m] SQL RUNTIME[[0;32m0.00089312s[0m][0m CMD[[0;33m/bin/hostname -f[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0023s[0m][0m STDOUT[ monitoring01.c.leafspace-183416.internal ][0m [1;37mLoad class 'Net_IPv6' from '/opt/observium/libs/pear/Net/IPv6.php': [0;32mOK[0m [1;37m ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_|[0;36m Observium Professional 18.5.9229 http://www.observium.org[0m [0m CMD[[0;33m/opt/observium/scripts/distro[0m] [0m Wrong process status! Issue in proc_get_status(), see: https://bugs.php.net/bug.php?id=69014 CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0088s[0m][0m STDOUT[ Linux|4.13.0-31-generic|amd64|Ubuntu|16.04|kvm| ][0m CMD[[0;33m/usr/bin/env python --version 2>&1[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0021s[0m][0m STDOUT[ Python 2.7.12 ][0m SQL[[0;33mSELECT version();[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00087810s[0m][0m CMD[[0;33m/usr/bin/snmpget --version 2>&1[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0023s[0m][0m STDOUT[ NET-SNMP version: 5.7.3 ][0m CMD[[0;33m/usr/bin/rrdtool --version | head -n1[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0068s[0m][0m STDOUT[ RRDtool 1.5.5 Copyright by Tobias Oetiker <tobi@oetiker.ch> ][0m CMD[[0;33m/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}'[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0365s[0m][0m STDOUT[ Apache/2.4.18 ][0m CMD[[0;33mdate "+%:z"[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0019s[0m][0m STDOUT[ +00:00 ][0m SQL[[0;33mSELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00089192s[0m][0m SQL[[0;33mSELECT @@SESSION.sql_mode;[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00066400s[0m][0m SQL[[0;33mSHOW VARIABLES LIKE 'character_set_connection'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00240302s[0m][0m [0;36m##### [1;37mSoftware versions[0;36m #####[0m [0m [0;36m o [1;37mOS [0m Linux 4.13.0-31-generic [amd64] (Ubuntu 16.04) [0;36m o [1;37mApache [0m 2.4.18 [0;36m o [1;37mPHP [0m 7.0.30-0ubuntu0.16.04.1 (OPcache: DISABLED) [0;36m o [1;37mPython [0m 2.7.12 [0;36m o [1;37mMySQL [0m 5.7.14-google-log (extension: mysqli 5.0.12-dev) [0;36m o [1;37mSNMP [0m NET-SNMP 5.7.3 [0;36m o [1;37mRRDtool [0m 1.5.5 [0;35m##### [1;37mMemory Limit[0;35m #####[0m [0m [0;35m o [1;37mPHP [0m Unlimited [0;35m##### [1;37mMySQL mode[0;35m #####[0m [0m [0;35m o [1;37mMySQL [0m NO_ZERO_IN_DATE,NO_ZERO_DATE,ERROR_FOR_DIVISION_BY_ZERO,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION [0;35m##### [1;37mCharset info[0;35m #####[0m [0m [0;35m o [1;37mPHP [0m UTF-8 [0;35m o [1;37mMySQL [0m utf8 [0;35m##### [1;37mTimezones info[0;35m #####[0m [0m [0;35m o [1;37mDate [0m Tuesday, 15-May-18 09:38:14 UTC [0;35m o [1;37mPHP [0m +00:00 [0;35m o [1;37mMySQL [0m +00:00 SQL[[0;33mSELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00074697s[0m][0m SQL[[0;33mSELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00060201s[0m][0m [1;37m##### [1;37m[1;37mStarting discovery run at 2018-05-15 09:38:14[1;37m #####[0m [0m SQL[[0;33mSELECT * FROM `devices` WHERE `disabled` = 0 AND `device_id` = '52' AND `status` = '1' ORDER BY `last_discovered_timetaken` ASC[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00104499s[0m][0m CMD[[0;33m/usr/bin/snmpget -v2c -c 'public' -Pu -OQUst -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' sysObjectID.0 sysUpTime.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0556s[0m][0m STDOUT[ sysObjectID.0 = enterprises.18334.1.2.1.2.1.131.2.8 sysUpTime.0 = 5939314 ][0m SNMP STATUS[[0;32mTRUE[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00117397s[0m][0m SQL[[0;33mSELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00104904s[0m][0m CMD[[0;33m/bin/ps -ww -o pid,ppid,uid,gid,tty,stat,time,lstart,args -p 21103[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0085s[0m][0m STDOUT[ PID PPID UID GID TT STAT TIME STARTED COMMAND 21103 6436 0 0 pts/2 S+ 00:00:00 Tue May 15 09:38:13 2018 php ./discovery.php -h 52 -dd ][0m SQL[[0;33mINSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('21103','discovery.php','6436','0','php ./discovery.php -h 52 -dd','1526377093','52')[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00462103s[0m][0m [1;44;96m > $device_discovery_cache_keys[0m[44;36m /opt/observium/includes/discovery/functions.inc.php:211 [0m array( [0] => string(10) "db_version" [1] => string(9) "localhost" [2] => string(8) "versions" [3] => string(8) "timezone" [4] => string(14) "entity_attribs" ) [0;32m##### [1;37mprinter01.hq.leaf.space [52][0;32m #####[0m [0m [0;32m o [1;37mOS Type [0m olivetti-printer [0;32m o [1;37mOS Group [0m printer [0;32m o [1;37mSNMP Version [0m v2c [0;32m o [1;37mLast discovery [0m 2018-05-15 09:18:04 [0;32m o [1;37mLast duration [0m 15.09 seconds [0;36m##### [1;37mModule Start: [1;31mos[0;36m #####[0m [0m CMD[[0;33m/usr/bin/snmpget -v2c -c 'public' -Pu -Ovq -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' sysDescr.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0265s[0m][0m STDOUT[ Generic 25C-9 ][0m SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpget -v2c -c 'public' -Pu -Ovqn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' sysObjectID.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0539s[0m][0m STDOUT[ .1.3.6.1.4.1.18334.1.2.1.2.1.131.2.8 ][0m SNMP STATUS[[0;32mTRUE[0m][0m [1;37mLoad class 'cli\Table' from '/opt/observium/libs/cli/Table.php': [0;32mOK[0m [1;37mLoad class 'cli\Shell' from '/opt/observium/libs/cli/Shell.php': [0;32mOK[0m [1;37mLoad class 'cli\table\Renderer' from '/opt/observium/libs/cli/table/Renderer.php': [0;32mOK[0m [1;37mLoad class 'cli\table\Tabular' from '/opt/observium/libs/cli/table/Tabular.php': [0;32mOK[0m [1;37mLoad class 'cli\Table\Ascii' from '/opt/observium/libs/cli/table/Ascii.php': [0;32mOK[0m [1;37mLoad class 'cli\Colors' from '/opt/observium/libs/cli/Colors.php': [0;32mOK[0m [1;37mLoad class 'cli\Streams' from '/opt/observium/libs/cli/Streams.php': [0;32mOK[0m +-------------+--------------------------------------+ | OID | | +-------------+--------------------------------------+ | sysDescr | Generic 25C-9 | | sysObjectID | .1.3.6.1.4.1.18334.1.2.1.2.1.131.2.8 | +-------------+--------------------------------------+ [0;35m o [1;37mDetect OS matched (olivetti-printer: Olivetti Printer):[0m +----------+---------------------+---------------+ | OID | Matched definition | | +----------+---------------------+---------------+ | sysDescr | /^Generic \w+-\w+$/ | Generic 25C-9 | +----------+---------------------+---------------+ [0;36m o [1;37msysORID table [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' sysORID[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0595s[0m][0m STDOUT[ .1.3.6.1.2.1.1.9.1.2 = No Such Object available on this agent at this OID ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUn, mib: 'SNMPv2-MIB', oid: 'sysORID', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.059541940689087 CMD[[0;33m/usr/bin/snmptranslate -On -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'SNMPv2-MIB::sysORID'[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0112s[0m][0m STDOUT[ .1.3.6.1.2.1.1.9.1.2 ][0m SNMP TRANSLATE (CMD): 'SNMPv2-MIB::sysORID' -> '.1.3.6.1.2.1.1.9.1.2' CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' sysORDescr[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m1.0644s[0m][0m STDOUT[ sysORDescr = No Such Object available on this agent at this OID ][0m SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'SNMPv2-MIB', oid: 'sysORDescr', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 1.0643630027771 <empty> SQL[[0;33mDELETE FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '52' AND `attrib_type` = 'sysORID'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00128603s[0m][0m [0;36m o [1;37mDuration [0m 1.2643s [0;36m##### [1;37mModule Start: [1;31mports[0;36m #####[0m [0m [0;35m o [1;37mCaching OIDs [0m ifDescr CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ifDescr[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m1.0423s[0m][0m STDOUT[ ifDescr.1 = Ethernet 10/100/1000 Base-T ifDescr.2 = Software Loopback ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m ifAlias CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ifAlias[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0515s[0m][0m STDOUT[ ifAlias = No Such Object available on this agent at this OID ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'IF-MIB', oid: 'ifAlias', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.05146598815918 ifName CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ifName[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m1.0539s[0m][0m STDOUT[ ifName = No Such Object available on this agent at this OID ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'IF-MIB', oid: 'ifName', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 1.0538818836212 ifType CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ifType[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0407s[0m][0m STDOUT[ ifType.1 = ethernetCsmacd ifType.2 = softwareLoopback ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m ifOperStatus CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ifOperStatus[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0413s[0m][0m STDOUT[ ifOperStatus.1 = up ifOperStatus.2 = up ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m SQL[[0;33mSELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '52' AND `attrib_type` = 'sysORID'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00134301s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00078201s[0m][0m SQL[[0;33mSELECT * FROM `observium_attribs`[0m][0m ROWS[[0;32m20[0m] SQL RUNTIME[[0;32m0.00074697s[0m][0m [1;44;96m [0m[44;36m /opt/observium/includes/discovery/ports.inc.php:36 [0m array( [1] => array( [ifDescr] => string(27) "Ethernet 10/100/1000 Base-T" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) [2] => array( [ifDescr] => string(17) "Software Loopback" [ifType] => string(16) "softwareLoopback" [ifOperStatus] => string(2) "up" ) ) [0;35m o [1;37mCaching DB [0m SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '52'[0m][0m ROWS[[0;32m2[0m] SQL RUNTIME[[0;32m0.00102711s[0m][0m 2 ports [0;35m o [1;37mDiscovering ports [0m .. ifIndex ifDescr ifName ifAlias ifType Oper Status Ignored 1 Ethernet 10/100/1000 Base-T ... ethernetCsmacd up no 2 Software Loopback ... softwareLoopback up no [0;36m o [1;37mDuration [0m 2.2544s [0;36m##### [1;37mModule Start: [1;31mports-stack[0;36m #####[0m [0m SQL[[0;33mSELECT * FROM `ports_stack` WHERE `device_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00086594s[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ifStackStatus[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0516s[0m][0m STDOUT[ ifStackStatus = No Such Object available on this agent at this OID ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'IF-MIB', oid: 'ifStackStatus', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.051576137542725 [0;36m o [1;37mDuration [0m 0.0568s [0;36m##### [1;37mModule Start: [1;31mvlans[0;36m #####[0m [0m SQL[[0;33mSELECT * FROM `vlans` WHERE `device_id` = '52';[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00140095s[0m][0m SQL[[0;33mSELECT * FROM `ports_vlans` WHERE `device_id` = '52';[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00074816s[0m][0m [1;44;96m > $ports_vlans_db[0m[44;36m /opt/observium/includes/discovery/vlans.inc.php:33 [0m array() [0;36m o [1;37mDuration [0m 0.0035s [0;36m##### [1;37mModule Start: [1;31moids[0;36m #####[0m [0m SQL[[0;33mSELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00084114s[0m][0m SQL[[0;33mSELECT * FROM `oids` WHERE `oid_autodiscover` = '1'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00068808s[0m][0m [0;36m o [1;37mDuration [0m 0.0019s [0;36m##### [1;37mModule Start: [1;31mip-addresses[0;36m #####[0m [0m [0;36m o [1;37mIP-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipAdEntIfIndex[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0429s[0m][0m STDOUT[ ipAdEntIfIndex.10.0.0.102 = 1 ipAdEntIfIndex.127.0.0.1 = 2 ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipAdEntNetMask[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0373s[0m][0m STDOUT[ ipAdEntNetMask.10.0.0.102 = 255.255.240.0 ipAdEntNetMask.127.0.0.1 = 255.0.0.0 ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipAddressIfIndex[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.052s[0m][0m STDOUT[ ipAddressIfIndex = No Such Object available on this agent at this OID ][0m SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'IP-MIB', oid: 'ipAddressIfIndex', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.051959991455078 [0;36m o [1;37mIPV6-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUsb -m IPV6-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipv6AddrEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0282s[0m][0m STDOUT[ ipv6AddrPfxLength.1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.1 = 128 ipv6AddrType.1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.1 = unknown ipv6AddrAnycastFlag.1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.1 = false ipv6AddrStatus.1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.1 = preferred ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m [1;44;96m > $ip_data[$ip_version][0m[44;36m /opt/observium/includes/discovery/ip-addresses.inc.php:28 [0m array( [1] => array( [10.0.0.102] => array( [ifIndex] => string(1) "1" [ip] => string(10) "10.0.0.102" [mask] => string(13) "255.255.240.0" [type] => string(7) "unicast" ) ) [2] => array( [127.0.0.1] => array( [ifIndex] => string(1) "2" [ip] => string(9) "127.0.0.1" [mask] => string(9) "255.0.0.0" [type] => string(7) "unicast" ) ) ) SQL[[0;33mSELECT * FROM `ipv4_addresses`[0m [0;33m LEFT JOIN `ports` USING(`port_id`)[0m [0;33m WHERE `device_id` = '52'[0m][0m ROWS[[0;32m2[0m] SQL RUNTIME[[0;32m0.00193191s[0m][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '52' AND `ifIndex` = '1' LIMIT 1[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00066710s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2860'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00083518s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2860'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00067711s[0m][0m SQL[[0;33mSELECT * FROM `devices` WHERE `device_id` = '52'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00087595s[0m][0m SQL[[0;33mSELECT * FROM `device_graphs` WHERE `device_id` = '52'[0m][0m ROWS[[0;32m24[0m] SQL RUNTIME[[0;32m0.00070786s[0m][0m [1;37mLoad class 'Net_IPv4' from '/opt/observium/libs/pear/Net/IPv4.php': [0;32mOK[0m SQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '10.0.0.0/20'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00068808s[0m][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '52' AND `ifIndex` = '2' LIMIT 1[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00063109s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2861'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00097680s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2861'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00062394s[0m][0m SQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00064898s[0m][0m SQL[[0;33mSELECT * FROM `ipv4_addresses`[0m [0;33m LEFT JOIN `ports` USING(`port_id`)[0m [0;33m WHERE `device_id` = '52'[0m][0m ROWS[[0;32m2[0m] SQL RUNTIME[[0;32m0.00093389s[0m][0m [1;44;96m [0m[44;36m /opt/observium/includes/discovery/ip-addresses.inc.php:28 [0m array( [1] => array( [0000:0000:0000:0000:0000:0000:0000:0001] => array( [ifIndex] => int(1) [ip] => string(39) "0000:0000:0000:0000:0000:0000:0000:0001" [prefix] => string(3) "128" [origin] => string(7) "unknown" ) ) ) SQL[[0;33mSELECT * FROM `ipv6_addresses`[0m [0;33m LEFT JOIN `ports` USING(`port_id`)[0m [0;33m WHERE `device_id` = '52'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00105906s[0m][0m SQL[[0;33mSELECT `ipv6_network_id` FROM `ipv6_networks` WHERE `ipv6_network` = '0:0:0:0:0:0:0:1/128'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00099587s[0m][0m SQL[[0;33mSELECT * FROM `ipv6_addresses`[0m [0;33m LEFT JOIN `ports` USING(`port_id`)[0m [0;33m WHERE `device_id` = '52'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00093508s[0m][0m ifIndex ifDescr IP: Version Address Network Origin 1 Ethernet 10/100/1000 Base-T IPv4 10.0.0.102/20 10.0.0.0/20 2 Software Loopback IPv4 127.0.0.1/8 127.0.0.0/8 1 Ethernet 10/100/1000 Base-T IPv6 ::1/128 0:0:0:0:0:0:0:1/128 unknown [0;36m o [1;37mChanges [0m 3 unchanged [0;36m o [1;37mDuration [0m 0.1945s [0;36m##### [1;37mModule Start: [1;31mprocessors[0;36m #####[0m [0m [0;36m o [1;37mUCD-SNMP-MIB [0m SQL[[0;33mSELECT COUNT(*) FROM `processors` WHERE `device_id` = '52' AND `processor_type` != 'ucd-old'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00068593s[0m][0m CMD[[0;33m/usr/bin/snmpget -v2c -c 'public' -Pu -OvQ -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ssCpuIdle.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0275s[0m][0m STDOUT[ No Such Object available on this agent at this OID ][0m SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpget, options: -OvQ, mib: 'UCD-SNMP-MIB', oid: 'ssCpuIdle.0', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.027470111846924 [0;36m o [1;37mHOST-RESOURCES-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' hrDevice[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m1.1298s[0m][0m STDOUT[ hrDeviceIndex.1 = 1 hrDeviceIndex.2 = 2 hrDeviceIndex.3 = 3 hrDeviceIndex.4 = 4 hrDeviceType.1 = hrDevicePrinter hrDeviceType.2 = hrDeviceOther hrDeviceType.3 = hrDeviceNetwork hrDeviceType.4 = hrDeviceDiskStorage hrDeviceDescr.1 = Generic 25C-9 hrDeviceDescr.2 = Generic 25C-9 hrDeviceDescr.3 = Ethernet 10/100/1000 Base-T hrDeviceDescr.4 = HDD hrDeviceID.1 = enterprises.18334.1.2.1.2.1.131.2.8 hrDeviceID.2 = enterprises.18334.1.2.1.2.1.131.2.8 hrDeviceID.3 = enterprises.18334.1.1.2.1.1.1.1 hrDeviceID.4 = enterprises.18334.1.1.3.1.1.1.2 hrDeviceStatus.1 = warning hrDeviceStatus.2 = running hrDeviceStatus.3 = running hrDeviceStatus.4 = running hrDeviceErrors.1 = 0 hrDeviceErrors.2 = 0 hrDeviceErrors.3 = 0 hrDeviceErrors.4 = 0 hrNetworkIfIndex.3 = 1 hrPrinterStatus.1 = idle hrPrinterDetectedErrorState.1 = "01 00 " ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' hrProcessorLoad[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0839s[0m][0m STDOUT[ hrProcessorLoad = No Such Instance currently exists at this OID ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES', oid: 'hrProcessorLoad', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.083930969238281 SQL[[0;33mSELECT * FROM `processors` WHERE `device_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00137401s[0m][0m [0;36m o [1;37mDuration [0m 1.2554s [0;36m##### [1;37mModule Start: [1;31mmempools[0;36m #####[0m [0m [0;36m o [1;37mUCD-SNMP-MIB [0m CMD[[0;33m/usr/bin/snmpget -v2c -c 'public' -Pu -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.027s[0m][0m STDOUT[ memTotalReal.0 = No Such Object available on this agent at this OID memAvailReal.0 = No Such Object available on this agent at this OID memBuffer.0 = No Such Object available on this agent at this OID memCached.0 = No Such Object available on this agent at this OID ][0m SNMP ERROR - device: 52, cmd: snmpget, options: -OQUs, mib: 'UCD-SNMP-MIB', oid: 'memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.026998043060303 SNMP STATUS[[0;31mFALSE[0m][0m [0;36m o [1;37mHOST-RESOURCES-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' hrStorageEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.1137s[0m][0m STDOUT[ hrStorageIndex.1 = 1 hrStorageIndex.2 = 2 hrStorageIndex.3 = 3 hrStorageIndex.4 = 4 hrStorageType.1 = hrStorageRam hrStorageType.2 = hrStorageFixedDisk hrStorageType.3 = hrStorageFlashMemory hrStorageType.4 = hrStorageOther hrStorageDescr.1 = RAM hrStorageDescr.2 = HDD hrStorageDescr.3 = SPIFlash hrStorageDescr.4 = eMMC hrStorageAllocationUnits.1 = 1048576 hrStorageAllocationUnits.2 = 1048576 hrStorageAllocationUnits.3 = 1048576 hrStorageAllocationUnits.4 = 1048576 hrStorageSize.1 = 2374 hrStorageSize.2 = 238454 hrStorageSize.3 = 2 hrStorageSize.4 = 4096 hrStorageUsed.1 = 2063 hrStorageUsed.2 = 107465 hrStorageUsed.3 = 2 hrStorageUsed.4 = 4096 hrStorageAllocationFailures.1 = 0 hrStorageAllocationFailures.2 = 0 hrStorageAllocationFailures.3 = 0 hrStorageAllocationFailures.4 = 0 ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m 52 -> 1, HOST-RESOURCES-MIB::, RAM, 1048576, 2374, 2063 SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '52' AND `mempool_index` = '1' AND `mempool_mib` = 'HOST-RESOURCES-MIB'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.01676917s[0m][0m 52 -> 4, HOST-RESOURCES-MIB::, eMMC, 1048576, 4096, 4096 SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '52' AND `mempool_index` = '4' AND `mempool_mib` = 'HOST-RESOURCES-MIB'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00156307s[0m][0m SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '52'[0m][0m ROWS[[0;32m2[0m] SQL RUNTIME[[0;32m0.00109482s[0m][0m 1 -> HOST-RESOURCES-MIB 4 -> HOST-RESOURCES-MIB [1;44;96m > $valid['mempool'][0m[44;36m /opt/observium/includes/discovery/mempools.inc.php:189 [0m array( [HOST-RESOURCES-MIB] => array( [1] => int(1) [4] => int(1) ) ) [0;36m o [1;37mChanges [0m 2 unchanged [0;36m o [1;37mDuration [0m 0.1695s [0;36m##### [1;37mModule Start: [1;31minventory[0;36m #####[0m [0m [0;36m o [1;37mENTITY-MIB [0m ENTITY-MIB CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'printer01.hq.leaf.space':'161' entPhysicalEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0927s[0m][0m STDOUT[ entPhysicalEntry = No Such Object available on this agent at this OID ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB', oid: 'entPhysicalEntry', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.092744112014771 [0;36m o [1;37mHOST-RESOURCES-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' hrDeviceEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.1267s[0m][0m STDOUT[ hrDeviceIndex.1 = 1 hrDeviceIndex.2 = 2 hrDeviceIndex.3 = 3 hrDeviceIndex.4 = 4 hrDeviceType.1 = hrDevicePrinter hrDeviceType.2 = hrDeviceOther hrDeviceType.3 = hrDeviceNetwork hrDeviceType.4 = hrDeviceDiskStorage hrDeviceDescr.1 = Generic 25C-9 hrDeviceDescr.2 = Generic 25C-9 hrDeviceDescr.3 = Ethernet 10/100/1000 Base-T hrDeviceDescr.4 = HDD hrDeviceID.1 = enterprises.18334.1.2.1.2.1.131.2.8 hrDeviceID.2 = enterprises.18334.1.2.1.2.1.131.2.8 hrDeviceID.3 = enterprises.18334.1.1.2.1.1.1.1 hrDeviceID.4 = enterprises.18334.1.1.3.1.1.1.2 hrDeviceStatus.1 = warning hrDeviceStatus.2 = running hrDeviceStatus.3 = running hrDeviceStatus.4 = running hrDeviceErrors.1 = 0 hrDeviceErrors.2 = 0 hrDeviceErrors.3 = 0 hrDeviceErrors.4 = 0 ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' hrProcessorEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0848s[0m][0m STDOUT[ hrProcessorEntry = No Such Object available on this agent at this OID ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES', oid: 'hrProcessorEntry', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.084847927093506 [1;44;96m > $hrDevices[0m[44;36m /opt/observium/includes/discovery/inventory/host-resources-mib.inc.php:20 [0m array( [1] => array( [hrDeviceIndex] => string(1) "1" [hrDeviceType] => string(15) "hrDevicePrinter" [hrDeviceDescr] => string(13) "Generic 25C-9" [hrDeviceID] => string(35) "enterprises.18334.1.2.1.2.1.131.2.8" [hrDeviceStatus] => string(7) "warning" [hrDeviceErrors] => string(1) "0" ) [2] => array( [hrDeviceIndex] => string(1) "2" [hrDeviceType] => string(13) "hrDeviceOther" [hrDeviceDescr] => string(13) "Generic 25C-9" [hrDeviceID] => string(35) "enterprises.18334.1.2.1.2.1.131.2.8" [hrDeviceStatus] => string(7) "running" [hrDeviceErrors] => string(1) "0" ) [3] => array( [hrDeviceIndex] => string(1) "3" [hrDeviceType] => string(15) "hrDeviceNetwork" [hrDeviceDescr] => string(27) "Ethernet 10/100/1000 Base-T" [hrDeviceID] => string(31) "enterprises.18334.1.1.2.1.1.1.1" [hrDeviceStatus] => string(7) "running" [hrDeviceErrors] => string(1) "0" ) [4] => array( [hrDeviceIndex] => string(1) "4" [hrDeviceType] => string(19) "hrDeviceDiskStorage" [hrDeviceDescr] => string(3) "HDD" [hrDeviceID] => string(31) "enterprises.18334.1.1.3.1.1.1.2" [hrDeviceStatus] => string(7) "running" [hrDeviceErrors] => string(1) "0" ) ) SQL[[0;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = '52' AND hrDeviceIndex = '1'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00137401s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDevicePrinter',`hrDeviceDescr` ='Generic 25C-9',`hrDeviceStatus` ='warning',`hrDeviceErrors` ='0',`hrProcessorLoad` =NULL WHERE device_id = '52' AND hrDeviceIndex = '1'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00073695s[0m][0m . SQL[[0;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = '52' AND hrDeviceIndex = '2'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00067997s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceOther',`hrDeviceDescr` ='Generic 25C-9',`hrDeviceStatus` ='running',`hrDeviceErrors` ='0',`hrProcessorLoad` =NULL WHERE device_id = '52' AND hrDeviceIndex = '2'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00059891s[0m][0m . SQL[[0;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = '52' AND hrDeviceIndex = '3'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00055480s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceNetwork',`hrDeviceDescr` ='Ethernet 10/100/1000 Base-T',`hrDeviceStatus` ='running',`hrDeviceErrors` ='0',`hrProcessorLoad` =NULL WHERE device_id = '52' AND hrDeviceIndex = '3'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00067496s[0m][0m . SQL[[0;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = '52' AND hrDeviceIndex = '4'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00061202s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceDiskStorage',`hrDeviceDescr` ='HDD',`hrDeviceStatus` ='running',`hrDeviceErrors` ='0',`hrProcessorLoad` =NULL WHERE device_id = '52' AND hrDeviceIndex = '4'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00065494s[0m][0m . SQL[[0;33mSELECT * FROM `hrDevice` WHERE `device_id` = '52'[0m][0m ROWS[[0;32m4[0m] SQL RUNTIME[[0;32m0.00068283s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00067401s[0m][0m [0;36m o [1;37mDuration [0m 0.3267s [0;36m##### [1;37mModule Start: [1;31mprintersupplies[0;36m #####[0m [0m [0;36m o [1;37mPrinter-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m Printer-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' prtMarkerSuppliesTable[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m1.3648s[0m][0m STDOUT[ prtMarkerSuppliesMarkerIndex.1.1 = 1 prtMarkerSuppliesMarkerIndex.1.2 = 1 prtMarkerSuppliesMarkerIndex.1.3 = 1 prtMarkerSuppliesMarkerIndex.1.4 = 1 prtMarkerSuppliesMarkerIndex.1.5 = 1 prtMarkerSuppliesMarkerIndex.1.6 = 1 prtMarkerSuppliesMarkerIndex.1.7 = 1 prtMarkerSuppliesMarkerIndex.1.8 = 1 prtMarkerSuppliesMarkerIndex.1.9 = 1 prtMarkerSuppliesMarkerIndex.1.10 = 1 prtMarkerSuppliesMarkerIndex.1.11 = 1 prtMarkerSuppliesMarkerIndex.1.12 = 1 prtMarkerSuppliesMarkerIndex.1.13 = 1 prtMarkerSuppliesMarkerIndex.1.14 = 1 prtMarkerSuppliesMarkerIndex.1.15 = 1 prtMarkerSuppliesMarkerIndex.1.16 = 1 prtMarkerSuppliesColorantIndex.1.1 = 1 prtMarkerSuppliesColorantIndex.1.2 = 2 prtMarkerSuppliesColorantIndex.1.3 = 3 prtMarkerSuppliesColorantIndex.1.4 = 4 prtMarkerSuppliesColorantIndex.1.5 = 1 prtMarkerSuppliesColorantIndex.1.6 = 1 prtMarkerSuppliesColorantIndex.1.7 = 2 prtMarkerSuppliesColorantIndex.1.8 = 2 prtMarkerSuppliesColorantIndex.1.9 = 3 prtMarkerSuppliesColorantIndex.1.10 = 3 prtMarkerSuppliesColorantIndex.1.11 = 4 prtMarkerSuppliesColorantIndex.1.12 = 4 prtMarkerSuppliesColorantIndex.1.13 = 0 prtMarkerSuppliesColorantIndex.1.14 = 0 prtMarkerSuppliesColorantIndex.1.15 = 0 prtMarkerSuppliesColorantIndex.1.16 = 0 prtMarkerSuppliesClass.1.1 = supplyThatIsConsumed prtMarkerSuppliesClass.1.2 = supplyThatIsConsumed prtMarkerSuppliesClass.1.3 = supplyThatIsConsumed prtMarkerSuppliesClass.1.4 = supplyThatIsConsumed prtMarkerSuppliesClass.1.5 = supplyThatIsConsumed prtMarkerSuppliesClass.1.6 = supplyThatIsConsumed prtMarkerSuppliesClass.1.7 = supplyThatIsConsumed prtMarkerSuppliesClass.1.8 = supplyThatIsConsumed prtMarkerSuppliesClass.1.9 = supplyThatIsConsumed prtMarkerSuppliesClass.1.10 = supplyThatIsConsumed prtMarkerSuppliesClass.1.11 = supplyThatIsConsumed prtMarkerSuppliesClass.1.12 = supplyThatIsConsumed prtMarkerSuppliesClass.1.13 = receptacleThatIsFilled prtMarkerSuppliesClass.1.14 = supplyThatIsConsumed prtMarkerSuppliesClass.1.15 = supplyThatIsConsumed prtMarkerSuppliesClass.1.16 = supplyThatIsConsumed prtMarkerSuppliesType.1.1 = toner prtMarkerSuppliesType.1.2 = toner prtMarkerSuppliesType.1.3 = toner prtMarkerSuppliesType.1.4 = toner prtMarkerSuppliesType.1.5 = opc prtMarkerSuppliesType.1.6 = developer prtMarkerSuppliesType.1.7 = opc prtMarkerSuppliesType.1.8 = developer prtMarkerSuppliesType.1.9 = opc prtMarkerSuppliesType.1.10 = developer prtMarkerSuppliesType.1.11 = opc prtMarkerSuppliesType.1.12 = developer prtMarkerSuppliesType.1.13 = wasteToner prtMarkerSuppliesType.1.14 = fuser prtMarkerSuppliesType.1.15 = transferUnit prtMarkerSuppliesType.1.16 = transferUnit prtMarkerSuppliesDescription.1.1 = "Toner (Cyan)" prtMarkerSuppliesDescription.1.2 = "Toner (Magenta)" prtMarkerSuppliesDescription.1.3 = "Toner (Yellow)" prtMarkerSuppliesDescription.1.4 = "Toner (Black)" prtMarkerSuppliesDescription.1.5 = "Drum Cartridge (Cyan)" prtMarkerSuppliesDescription.1.6 = "Developer Cartridge (Cyan)" prtMarkerSuppliesDescription.1.7 = "Drum Cartridge (Magenta)" prtMarkerSuppliesDescription.1.8 = "Developer Cartridge (Magenta)" prtMarkerSuppliesDescription.1.9 = "Drum Cartridge (Yellow)" prtMarkerSuppliesDescription.1.10 = "Developer Cartridge (Yellow)" prtMarkerSuppliesDescription.1.11 = "Drum Cartridge (Black)" prtMarkerSuppliesDescription.1.12 = "Developer Cartridge (Black)" prtMarkerSuppliesDescription.1.13 = "Waste Toner Box" prtMarkerSuppliesDescription.1.14 = "Fusing Unit" prtMarkerSuppliesDescription.1.15 = "Image Transfer Belt Unit" prtMarkerSuppliesDescription.1.16 = "Transfer Roller Unit" prtMarkerSuppliesSupplyUnit.1.1 = percent prtMarkerSuppliesSupplyUnit.1.2 = percent prtMarkerSuppliesSupplyUnit.1.3 = percent prtMarkerSuppliesSupplyUnit.1.4 = percent prtMarkerSuppliesSupplyUnit.1.5 = percent prtMarkerSuppliesSupplyUnit.1.6 = percent prtMarkerSuppliesSupplyUnit.1.7 = percent prtMarkerSuppliesSupplyUnit.1.8 = percent prtMarkerSuppliesSupplyUnit.1.9 = percent prtMarkerSuppliesSupplyUnit.1.10 = percent prtMarkerSuppliesSupplyUnit.1.11 = percent prtMarkerSuppliesSupplyUnit.1.12 = percent prtMarkerSuppliesSupplyUnit.1.13 = other prtMarkerSuppliesSupplyUnit.1.14 = percent prtMarkerSuppliesSupplyUnit.1.15 = percent prtMarkerSuppliesSupplyUnit.1.16 = percent prtMarkerSuppliesMaxCapacity.1.1 = 100 prtMarkerSuppliesMaxCapacity.1.2 = 100 prtMarkerSuppliesMaxCapacity.1.3 = 100 prtMarkerSuppliesMaxCapacity.1.4 = 100 prtMarkerSuppliesMaxCapacity.1.5 = 100 prtMarkerSuppliesMaxCapacity.1.6 = 100 prtMarkerSuppliesMaxCapacity.1.7 = 100 prtMarkerSuppliesMaxCapacity.1.8 = 100 prtMarkerSuppliesMaxCapacity.1.9 = 100 prtMarkerSuppliesMaxCapacity.1.10 = 100 prtMarkerSuppliesMaxCapacity.1.11 = 100 prtMarkerSuppliesMaxCapacity.1.12 = 100 prtMarkerSuppliesMaxCapacity.1.13 = -2 prtMarkerSuppliesMaxCapacity.1.14 = 100 prtMarkerSuppliesMaxCapacity.1.15 = 100 prtMarkerSuppliesMaxCapacity.1.16 = 100 prtMarkerSuppliesLevel.1.1 = 100 prtMarkerSuppliesLevel.1.2 = 100 prtMarkerSuppliesLevel.1.3 = 100 prtMarkerSuppliesLevel.1.4 = 100 prtMarkerSuppliesLevel.1.5 = 99 prtMarkerSuppliesLevel.1.6 = 99 prtMarkerSuppliesLevel.1.7 = 99 prtMarkerSuppliesLevel.1.8 = 99 prtMarkerSuppliesLevel.1.9 = 99 prtMarkerSuppliesLevel.1.10 = 99 prtMarkerSuppliesLevel.1.11 = 99 prtMarkerSuppliesLevel.1.12 = 99 prtMarkerSuppliesLevel.1.13 = -3 prtMarkerSuppliesLevel.1.14 = 99 prtMarkerSuppliesLevel.1.15 = 99 prtMarkerSuppliesLevel.1.16 = 99 ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m Printer-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' prtMarkerColorantTable[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0593s[0m][0m STDOUT[ prtMarkerColorantMarkerIndex.1.1 = 1 prtMarkerColorantMarkerIndex.1.2 = 1 prtMarkerColorantMarkerIndex.1.3 = 1 prtMarkerColorantMarkerIndex.1.4 = 1 prtMarkerColorantRole.1.1 = process prtMarkerColorantRole.1.2 = process prtMarkerColorantRole.1.3 = process prtMarkerColorantRole.1.4 = process prtMarkerColorantValue.1.1 = "cyan" prtMarkerColorantValue.1.2 = "magenta" prtMarkerColorantValue.1.3 = "yellow" prtMarkerColorantValue.1.4 = "black" prtMarkerColorantTonality.1.1 = 256 prtMarkerColorantTonality.1.2 = 256 prtMarkerColorantTonality.1.3 = 256 prtMarkerColorantTonality.1.4 = 256 ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.1'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00129390s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.1'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00080395s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.2'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00080490s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.2'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00077891s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.3'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00062203s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.3'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00064397s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.4'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00058413s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.4'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00069380s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.5'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00068998s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.5'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00073791s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.6'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00062895s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.6'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00061393s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.7'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00061178s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.7'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00078917s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.8'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00068998s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.8'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00064516s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.9'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00060296s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.9'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00063396s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.10'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00067496s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.10'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00067496s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.11'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00066900s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.11'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00063801s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.12'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00058007s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.12'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00073910s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.13'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00069714s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.13'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00071383s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.14'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00063086s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.14'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00068283s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.15'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00064087s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.15'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00073981s[0m][0m SQL[[0;33mSELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.16'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00062203s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.16'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00073385s[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52'[0m][0m ROWS[[0;32m16[0m] SQL RUNTIME[[0;32m0.00074100s[0m][0m ................ [0;36m o [1;37mChanges [0m 16 unchanged [0;36m o [1;37mDuration [0m 1.4598s [0;36m##### [1;37mModule Start: [1;31msensors[0;36m #####[0m [0m [0;36m o [1;37mPrinter-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m Printer-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' prtMarkerEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0671s[0m][0m STDOUT[ prtMarkerMarkTech.1.1 = electrophotographicLaser prtMarkerCounterUnit.1.1 = impressions prtMarkerLifeCount.1.1 = 38 prtMarkerPowerOnCount.1.1 = 20 prtMarkerProcessColorants.1.1 = 4 prtMarkerSpotColorants.1.1 = 0 prtMarkerAddressabilityUnit.1.1 = tenThousandthsOfInches prtMarkerAddressabilityFeedDir.1.1 = 600 prtMarkerAddressabilityXFeedDir.1.1 = 1800 prtMarkerNorthMargin.1.1 = 1667 prtMarkerSouthMargin.1.1 = 1181 prtMarkerWestMargin.1.1 = 1181 prtMarkerEastMargin.1.1 = 1181 prtMarkerStatus.1.1 = 0 ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m Printer-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' prtMarkerSuppliesDescription[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0836s[0m][0m STDOUT[ prtMarkerSuppliesDescription.1.1 = "Toner (Cyan)" prtMarkerSuppliesDescription.1.2 = "Toner (Magenta)" prtMarkerSuppliesDescription.1.3 = "Toner (Yellow)" prtMarkerSuppliesDescription.1.4 = "Toner (Black)" prtMarkerSuppliesDescription.1.5 = "Drum Cartridge (Cyan)" prtMarkerSuppliesDescription.1.6 = "Developer Cartridge (Cyan)" prtMarkerSuppliesDescription.1.7 = "Drum Cartridge (Magenta)" prtMarkerSuppliesDescription.1.8 = "Developer Cartridge (Magenta)" prtMarkerSuppliesDescription.1.9 = "Drum Cartridge (Yellow)" prtMarkerSuppliesDescription.1.10 = "Developer Cartridge (Yellow)" prtMarkerSuppliesDescription.1.11 = "Drum Cartridge (Black)" prtMarkerSuppliesDescription.1.12 = "Developer Cartridge (Black)" prtMarkerSuppliesDescription.1.13 = "Waste Toner Box" prtMarkerSuppliesDescription.1.14 = "Fusing Unit" prtMarkerSuppliesDescription.1.15 = "Image Transfer Belt Unit" prtMarkerSuppliesDescription.1.16 = "Transfer Roller Unit" ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_mib` = 'jetdirect' AND `supply_index` = '1.1'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00136399s[0m][0m Discover sensor: counter, printer01.hq.leaf.space, .1.3.6.1.2.1.43.10.2.1.4.1.1, 1.1, Printer-MIB-prtMarkerLifeCount, Total Printed Impressions, SCALE: 1, LIMITS: (, , , ), CURRENT: 38, snmp, , SQL[[0;33mSELECT COUNT(`sensor_id`) FROM `sensors`[0m [0;33m WHERE `poller_type`= 'snmp' AND `sensor_class` = 'counter' AND `device_id` = '52' AND `sensor_type` = 'Printer-MIB-prtMarkerLifeCount' AND `sensor_index` = '1.1'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00092697s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'counter' AND `device_id` = '52' AND `sensor_type` = 'Printer-MIB-prtMarkerLifeCount' AND `sensor_index` = '1.1'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00083899s[0m][0m Compare float numbers: "1" with "1", epsilon: "1.0E-5", comparision: "0 < 1.0E-5", numbers: SAME Compare float numbers: "0" with "0", epsilon: "1.0E-5", comparision: "0 < 1.0E-5", numbers: SAME SQL[[0;33mSELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '450' AND `attrib_type` = 'sensor_addition'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00076580s[0m][0m .Discover sensor: counter, printer01.hq.leaf.space, .1.3.6.1.2.1.43.10.2.1.5.1.1, 1.1, Printer-MIB-prtMarkerPowerOnCount, PowerOn Printed Impressions - Toner (Cyan), SCALE: 1, LIMITS: (, , , ), CURRENT: 20, snmp, , SQL[[0;33mSELECT COUNT(`sensor_id`) FROM `sensors`[0m [0;33m WHERE `poller_type`= 'snmp' AND `sensor_class` = 'counter' AND `device_id` = '52' AND `sensor_type` = 'Printer-MIB-prtMarkerPowerOnCount' AND `sensor_index` = '1.1'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00064993s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'counter' AND `device_id` = '52' AND `sensor_type` = 'Printer-MIB-prtMarkerPowerOnCount' AND `sensor_index` = '1.1'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00087094s[0m][0m Compare float numbers: "1" with "1", epsilon: "1.0E-5", comparision: "0 < 1.0E-5", numbers: SAME Compare float numbers: "0" with "0", epsilon: "1.0E-5", comparision: "0 < 1.0E-5", numbers: SAME SQL[[0;33mSELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '451' AND `attrib_type` = 'sensor_addition'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00075603s[0m][0m . [0;36m o [1;37mENTITY-SENSOR-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' entPhySensorValue[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0523s[0m][0m STDOUT[ entPhySensorValue = No Such Object available on this agent at this OID ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'ENTITY-MIB:ENTITY-SENSOR-MIB', oid: 'entPhySensorValue', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.052258968353271 [1;44;96m > $valid['sensor'][0m[44;36m /opt/observium/includes/discovery/sensors.inc.php:699 [0m array( [counter] => array( [Printer-MIB-prtMarkerLifeCount] => array( [1.1] => int(1) ) [Printer-MIB-prtMarkerPowerOnCount] => array( [1.1] => int(1) ) ) ) SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00132298s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00073099s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00062394s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00067997s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00077200s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00066209s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00080919s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'charge' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00063896s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00078702s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'energy' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00074792s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00061202s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00066900s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00060105s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00064898s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00070906s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00066614s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00074601s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00065708s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00065494s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00063705s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00059295s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00070906s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00071812s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00060892s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00064397s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00078821s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00066400s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00064898s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00069094s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'counter' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m ROWS[[0;32m2[0m] SQL RUNTIME[[0;32m0.00073481s[0m][0m [1;44;96m > $valid['status'][0m[44;36m /opt/observium/includes/discovery/sensors.inc.php:705 [0m array() SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '52' AND `poller_type` = 'snmp' AND `status_deleted` = '0'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00070596s[0m][0m [0;36m o [1;37mDuration [0m 0.2498s [0;36m##### [1;37mModule Start: [1;31mstorage[0;36m #####[0m [0m [0;36m o [1;37mUCD-SNMP-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' dskEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.06s[0m][0m STDOUT[ dskEntry = No Such Object available on this agent at this OID ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'UCD-SNMP-MIB', oid: 'dskEntry', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.06002402305603 [0;36m o [1;37mHOST-RESOURCES-MIB [0m 52 -> 2, hrStorageFixedDisk, HOST-RESOURCES-MIB, HDD, 1048576, 250037141504, 112685219840, 0 SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '52' AND `storage_index` = '2' AND `storage_mib` = 'host-resources-mib'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00124002s[0m][0m [1;44;96m > $update[0m[44;36m /opt/observium/includes/discovery/functions.inc.php:1274 [0m array() 52 -> 3, hrStorageFlashMemory, HOST-RESOURCES-MIB, SPIFlash, 1048576, 2097152, 2097152, 0 SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '52' AND `storage_index` = '3' AND `storage_mib` = 'host-resources-mib'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00076699s[0m][0m [1;44;96m [0m[44;36m /opt/observium/includes/discovery/functions.inc.php:1274 [0m array() [1;44;96m > $valid['storage'][0m[44;36m /opt/observium/includes/discovery/storage.inc.php:19 [0m array( [host-resources-mib] => array( [2] => string(3) "HDD" [3] => string(8) "SPIFlash" ) ) SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '52'[0m][0m ROWS[[0;32m2[0m] SQL RUNTIME[[0;32m0.00141692s[0m][0m 2 -> host-resources-mib 3 -> host-resources-mib [1;44;96m > $valid[$module][0m[44;36m /opt/observium/includes/discovery/storage.inc.php:40 [0m array( [host-resources-mib] => array( [2] => string(3) "HDD" [3] => string(8) "SPIFlash" ) ) [0;36m o [1;37mChanges [0m 2 unchanged [0;36m o [1;37mDuration [0m 0.0708s [0;36m##### [1;37mModule Start: [1;31mneighbours[0;36m #####[0m [0m [0;36m o [1;37mLLDP-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' lldpRemChassisIdSubtype[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0569s[0m][0m STDOUT[ lldpRemChassisIdSubtype = No Such Object available on this agent at this OID ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'LLDP-MIB', oid: 'lldpRemChassisIdSubtype', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.056887865066528 [1;44;96m [0m[44;36m /opt/observium/includes/discovery/neighbours/lldp-mib.inc.php:28 [0m array() SQL[[0;33mSELECT * FROM `neighbours` LEFT JOIN `ports` USING(`port_id`) WHERE `device_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00112700s[0m][0m [0;36m o [1;37mDuration [0m 0.0622s [0;36m##### [1;37mModule Start: [1;31marp-table[0;36m #####[0m [0m SQL[[0;33mSELECT port_id, ifIndex FROM ports WHERE device_id = '52' GROUP BY port_id[0m][0m ROWS[[0;32m2[0m] SQL RUNTIME[[0;32m0.00073409s[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipNetToPhysicalPhysAddress[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0505s[0m][0m STDOUT[ ipNetToPhysicalPhysAddress No Such Object available on this agent at this OID ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OXqs, mib: 'IP-MIB', oid: 'ipNetToPhysicalPhysAddress', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.050471782684326 CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OXqs -m IPV6-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipv6NetToMediaPhysAddress[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m6.0364s[0m][0m STDOUT[ ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipNetToMediaPhysAddress[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.307s[0m][0m STDOUT[ ipNetToMediaPhysAddress[1][10.0.0.1] e4:8d:8c:f:15:9b ipNetToMediaPhysAddress[1][10.0.0.3] 70:4f:57:37:6c:db ipNetToMediaPhysAddress[1][10.0.0.101] 0:4:56:a9:5f:a ipNetToMediaPhysAddress[1][10.0.0.200] 4c:cc:6a:6e:45:44 ipNetToMediaPhysAddress[1][10.0.2.2] 64:0:6a:84:ce:ae ipNetToMediaPhysAddress[1][10.0.2.3] 64:0:6a:84:cf:42 ipNetToMediaPhysAddress[1][10.0.2.7] d8:9e:f3:74:58:b7 ipNetToMediaPhysAddress[1][10.0.2.8] d8:9e:f3:75:4:ac ipNetToMediaPhysAddress[1][10.0.2.100] 78:4f:43:5c:13:5a ipNetToMediaPhysAddress[1][10.0.2.101] f8:da:c:4c:10:47 ipNetToMediaPhysAddress[1][10.0.5.76] 0:4:56:a9:5d:e0 ipNetToMediaPhysAddress[1][10.0.5.159] 64:0:6a:be:e2:d8 ipNetToMediaPhysAddress[1][10.0.5.160] bc:30:5b:ee:56:f0 ipNetToMediaPhysAddress[1][169.254.229.29] f8:da:c:4c:10:47 ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;32mTRUE[0m][0m Used IP-MIB::ipNetToMediaPhysAddress SQL[[0;33mSELECT mac_id, mac_address, ip_address, ip_version, ifIndex FROM ip_mac AS M[0m [0;33m LEFT JOIN ports AS I ON M.port_id = I.port_id[0m [0;33m WHERE I.device_id = '52'[0m][0m ROWS[[0;32m13[0m] SQL RUNTIME[[0;32m0.00207281s[0m][0m ....... SQL[[0;33mINSERT INTO `ip_mac` (`port_id`,`mac_address`,`ip_address`,`ip_version`) VALUES ('2860','d89ef37504ac','10.0.2.8','4')[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00516701s[0m][0m Added MAC address d8:9e:f3:75:04:ac for 10.0.2.8 +...... [0;36m o [1;37mDuration [0m 6.4156s [0;36m##### [1;37mModule Start: [1;31mjunose-atm-vp[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0007s [0;36m##### [1;37mModule Start: [1;31mbgp-peers[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0025s [0;36m##### [1;37mModule Start: [1;31mmac-accounting[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0002s Module [ cisco-vrf ] is in the blacklist for printer [0;36m##### [1;37mModule Start: [1;31msla[0;36m #####[0m [0m [0;36m o [1;37mDISMAN-PING-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m DISMAN-PING-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' pingCtlEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0568s[0m][0m STDOUT[ pingCtlEntry = No Such Object available on this agent at this OID ][0m SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'DISMAN-PING-MIB', oid: 'pingCtlEntry', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.056824922561646 [1;44;96m > $sla_table[0m[44;36m /opt/observium/includes/discovery/sla.inc.php:22 [0m null SQL[[0;33mSELECT * FROM `slas` WHERE `device_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00121403s[0m][0m [1;44;96m [0m[44;36m /opt/observium/includes/discovery/sla.inc.php:40 [0m array() [0;36m o [1;37mDuration [0m 0.0637s [0;36m##### [1;37mModule Start: [1;31mlsp[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0001s [0;36m##### [1;37mModule Start: [1;31mpseudowires[0;36m #####[0m [0m SQL[[0;33mSELECT * FROM `pseudowires` WHERE `device_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00093102s[0m][0m [0;36m o [1;37mDuration [0m 0.0016s [0;36m##### [1;37mModule Start: [1;31mvirtual-machines[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0005s Module [ cisco-cbqos ] is in the blacklist for printer [0;36m##### [1;37mModule Start: [1;31mucd-diskio[0;36m #####[0m [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m UCD-DISKIO-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' diskIOEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0516s[0m][0m STDOUT[ diskIOEntry = No Such Object available on this agent at this OID ][0m All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'UCD-DISKIO-MIB', oid: 'diskIOEntry', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.05161714553833 SQL[[0;33mSELECT * FROM `ucd_diskio` WHERE `device_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00113797s[0m][0m [0;36m o [1;37mDuration [0m 0.057s [0;36m##### [1;37mModule Start: [1;31mwifi[0;36m #####[0m [0m SQL[[0;33mSELECT * FROM `wifi_radios` WHERE `device_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00093603s[0m][0m SQL[[0;33mSELECT * FROM `wifi_wlans` WHERE `device_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00086403s[0m][0m SQL[[0;33mSELECT * FROM `wifi_aps` WHERE `device_id` = '52'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00085282s[0m][0m [0;36m o [1;37mDuration [0m 0.0036s [0;36m##### [1;37mModule Start: [1;31mp2p-radios[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0001s [0;36m##### [1;37mModule Start: [1;31mgraphs[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0004s Module [ services ] disabled globally. Module [ raid ] disabled globally. SQL[[0;33mSELECT `device_state` FROM `devices` WHERE `device_id` = '52';[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00104189s[0m][0m [1;44;96m > $old_device_state['discovery_history'][0m[44;36m /opt/observium/includes/discovery/functions.inc.php:388 [0m array( [1526375869] => double(15.0863) [1526366050] => double(13.7733) [1526344449] => double(12.9566) [1526322886] => double(10.7845) [1526306401] => double(17.9989) ) [1;44;96m > $discovery_history[0m[44;36m /opt/observium/includes/discovery/functions.inc.php:391 [0m array( [1526377094] => double(13.9382) [1526375869] => double(15.0863) [1526366050] => double(13.7733) [1526344449] => double(12.9566) [1526322886] => double(10.7845) [1526306401] => double(17.9989) ) SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`type` ='printer',`last_discovered_timetaken` ='13.9382',`force_discovery` ='0',`device_state` ='a:3:{s:15:\"poller_mod_perf\";a:27:{s:6:\"system\";d:1.5879000000000001;s:2:\"os\";d:0.83699999999999997;s:7:\"sensors\";d:0.47070000000000001;s:6:\"status\";d:0.0011000000000000001;s:10:\"processors\";d:0.0025999999999999999;s:8:\"mempools\";d:0.31659999999999999;s:7:\"storage\";d:0.0129;s:8:\"netstats\";d:1.4885999999999999;s:6:\"hr-mib\";d:0.12540000000000001;s:7:\"ucd-mib\";d:0.14480000000000001;s:13:\"ipSystemStats\";d:0.2306;s:5:\"ports\";d:0.93300000000000005;s:9:\"bgp-peers\";d:0.0030000000000000001;s:15:\"printersupplies\";d:4.1532999999999998;s:10:\"ucd-diskio\";d:0.0032000000000000002;s:4:\"wifi\";d:0.00020000000000000001;s:10:\"p2p-radios\";d:0.0132;s:4:\"ospf\";d:0.00050000000000000001;s:3:\"sla\";d:0.0015;s:11:\"pseudowires\";d:0.0040000000000000001;s:14:\"mac-accounting\";d:0.0091999999999999998;s:12:\"loadbalancer\";d:0.00040000000000000002;s:15:\"entity-physical\";d:0.00020000000000000001;s:12:\"applications\";d:0.0022000000000000001;s:9:\"fdb-table\";d:0.22259999999999999;s:6:\"graphs\";d:0.00040000000000000002;s:4:\"oids\";d:0.0030000000000000001;}s:14:\"poller_history\";a:236:{i:1526376904;d:12.1051;i:1526376605;d:18.412199999999999;i:1526376305;d:11.5501;i:1526376005;d:12.407500000000001;i:1526375705;d:17.484999999999999;i:1526375405;d:13.962999999999999;i:1526375106;d:12.956;i:1526374805;d:21.3108;i:1526374505;d:16.272400000000001;i:1526374205;d:15.905099999999999;i:1526373905;d:15.2522;i:1526373605;d:13.5852;i:1526373305;d:11.9674;i:1526373005;d:10.890599999999999;i:1526372705;d:11.3035;i:1526372404;d:17.100000000000001;i:1526372104;d:18.746300000000002;i:1526371805;d:17.157299999999999;i:1526371504;d:13.1174;i:1526371205;d:17.206399999999999;i:1526370905;d:15.4923;i:1526370605;d:13.1305;i:1526370306;d:11.503;i:1526370005;d:14.3498;i:1526369705;d:16.347000000000001;i:1526369405;d:17.901499999999999;i:1526369105;d:13.316599999999999;i:1526368804;d:15.5297;i:1526368505;d:16.3188;i:1526368205;d:15.7143;i:1526367905;d:17.190200000000001;i:1526367604;d:19.297799999999999;i:1526367306;d:18.284700000000001;i:1526367005;d:15.2506;i:1526366705;d:14.44;i:1526366405;d:12.0867;i:1526366105;d:16.135899999999999;i:1526365805;d:11.339;i:1526365506;d:16.481100000000001;i:1526365205;d:12.1479;i:1526364905;d:14.555400000000001;i:1526364605;d:14.640000000000001;i:1526364305;d:17.093599999999999;i:1526364004;d:13.743600000000001;i:1526363705;d:18.050899999999999;i:1526363405;d:11.6281;i:1526363105;d:12.4727;i:1526362804;d:13.668699999999999;i:1526362505;d:16.313400000000001;i:1526362205;d:14.5365;i:1526361905;d:15.922700000000001;i:1526361605;d:14.3049;i:1526361305;d:10.450200000000001;i:1526361005;d:11.308199999999999;i:1526360705;d:19.616800000000001;i:1526360405;d:17.132400000000001;i:1526360105;d:12.1012;i:1526359805;d:14.23;i:1526359505;d:17.5488;i:1526359205;d:11.397500000000001;i:1526358905;d:14.823499999999999;i:1526358605;d:12.142300000000001;i:1526358305;d:14.411099999999999;i:1526358005;d:11.3904;i:1526357705;d:14.9223;i:1526357404;d:12.7827;i:1526357105;d:16.279599999999999;i:1526356805;d:14.536799999999999;i:1526356505;d:12.984500000000001;i:1526356205;d:16.8432;i:1526355905;d:12.1945;i:1526355605;d:10.656700000000001;i:1526355305;d:14.285399999999999;i:1526355005;d:16.9894;i:1526354705;d:12.8903;i:1526354405;d:15.753;i:1526354105;d:13.888400000000001;i:1526353805;d:12.302;i:1526353505;d:11.434200000000001;i:1526353205;d:11.786899999999999;i:1526352905;d:12.736800000000001;i:1526352605;d:11.646000000000001;i:1526352305;d:14.3141;i:1526352005;d:15.9626;i:1526351706;d:15.6332;i:1526351405;d:16.217500000000001;i:1526351105;d:15.963800000000001;i:1526350805;d:19.168099999999999;i:1526350504;d:15.7841;i:1526350204;d:15.9526;i:1526349905;d:16.319800000000001;i:1526349605;d:15.128399999999999;i:1526349305;d:11.909000000000001;i:1526349005;d:15.1516;i:1526348704;d:12.286300000000001;i:1526348405;d:16.048300000000001;i:1526348104;d:15.3292;i:1526347805;d:16.3797;i:1526347504;d:17.375299999999999;i:1526347205;d:13.1403;i:1526346905;d:17.333100000000002;i:1526346605;d:10.985799999999999;i:1526346305;d:15.2759;i:1526346005;d:14.3919;i:1526345705;d:10.383800000000001;i:1526345405;d:14.526400000000001;i:1526345105;d:16.248899999999999;i:1526344805;d:16.146100000000001;i:1526344506;d:12.958600000000001;i:1526344206;d:12.1821;i:1526343905;d:13.2066;i:1526343606;d:14.0418;i:1526343305;d:14.2896;i:1526343005;d:16.834800000000001;i:1526342705;d:18.266400000000001;i:1526342405;d:15.592700000000001;i:1526342105;d:11.6577;i:1526341805;d:16.041599999999999;i:1526341505;d:12.7509;i:1526341205;d:11.8164;i:1526340905;d:16.854099999999999;i:1526340605;d:12.947699999999999;i:1526340305;d:11.982100000000001;i:1526340005;d:17.996099999999998;i:1526339705;d:17.577400000000001;i:1526339405;d:17.638400000000001;i:1526339105;d:13.919499999999999;i:1526338805;d:18.907;i:1526338505;d:14.2447;i:1526338205;d:14.700799999999999;i:1526337905;d:14.1858;i:1526337605;d:13.5931;i:1526337305;d:17.133299999999998;i:1526337005;d:12.571099999999999;i:1526336706;d:13.2575;i:1526336405;d:15.975899999999999;i:1526336105;d:17.888000000000002;i:1526335805;d:13.7074;i:1526335505;d:18.2105;i:1526335205;d:14.6595;i:1526334905;d:12.251899999999999;i:1526334605;d:14.273899999999999;i:1526334305;d:13.248200000000001;i:1526334005;d:14.773899999999999;i:1526333705;d:10.6995;i:1526333405;d:12.0206;i:1526333105;d:13.1746;i:1526332805;d:14.9795;i:1526332505;d:12.070600000000001;i:1526332205;d:11.630699999999999;i:1526331905;d:14.648999999999999;i:1526331605;d:15.286799999999999;i:1526331305;d:14.239800000000001;i:1526331005;d:12.976599999999999;i:1526330705;d:14.764799999999999;i:1526330405;d:17.330200000000001;i:1526330105;d:15.3689;i:1526329805;d:16.1846;i:1526329505;d:12.6465;i:1526329205;d:12.960699999999999;i:1526328905;d:17.167200000000001;i:1526328605;d:13.725300000000001;i:1526328306;d:15.952500000000001;i:1526328005;d:15.353199999999999;i:1526327705;d:12.0761;i:1526327405;d:16.030000000000001;i:1526327105;d:15.224299999999999;i:1526326806;d:17.9163;i:1526326506;d:13.2439;i:1526326205;d:12.5313;i:1526325905;d:14.453200000000001;i:1526325605;d:17.945499999999999;i:1526325305;d:14.6938;i:1526325006;d:20.107500000000002;i:1526324706;d:14.5945;i:1526324405;d:13.8718;i:1526324105;d:20.3657;i:1526323805;d:14.8916;i:1526323505;d:13.8345;i:1526323205;d:16.129899999999999;i:1526322905;d:13.1242;i:1526322605;d:16.2315;i:1526322306;d:13.877599999999999;i:1526322005;d:11.253;i:1526321706;d:13.172700000000001;i:1526321405;d:14.582599999999999;i:1526321106;d:17.8292;i:1526320805;d:15.4457;i:1526320505;d:17.921399999999998;i:1526320206;d:17.193000000000001;i:1526319905;d:12.027100000000001;i:1526319605;d:14.818099999999999;i:1526319306;d:13.1325;i:1526319005;d:12.2872;i:1526318705;d:14.8878;i:1526318406;d:15.705;i:1526318105;d:14.186400000000001;i:1526317812;d:15.832599999999999;i:1526317505;d:46.1464;i:1526317205;d:13.8063;i:1526316905;d:16.542899999999999;i:1526316605;d:12.2072;i:1526316305;d:12.939;i:1526316005;d:15.5909;i:1526315705;d:13.2255;i:1526315405;d:14.7119;i:1526315105;d:15.772500000000001;i:1526314805;d:16.9711;i:1526314505;d:13.629300000000001;i:1526314205;d:16.9665;i:1526313906;d:13.9666;i:1526313605;d:12.7348;i:1526313305;d:13.137700000000001;i:1526313006;d:13.175800000000001;i:1526312705;d:13.4872;i:1526312405;d:19.6236;i:1526312105;d:15.668699999999999;i:1526311805;d:13.8835;i:1526311505;d:11.6706;i:1526311206;d:15.571899999999999;i:1526310905;d:17.77;i:1526310605;d:11.7826;i:1526310306;d:15.680899999999999;i:1526310006;d:14.158799999999999;i:1526309705;d:14.908300000000001;i:1526309405;d:16.721399999999999;i:1526309106;d:16.821899999999999;i:1526308805;d:24.448799999999999;i:1526308505;d:14.107900000000001;i:1526308205;d:14.505100000000001;i:1526307905;d:16.6511;i:1526307605;d:14.505699999999999;i:1526307305;d:20.250800000000002;i:1526307005;d:19.255800000000001;i:1526306706;d:12.5671;i:1526306420;d:11.337400000000001;}s:17:\"discovery_history\";a:6:{i:1526377094;d:13.9382;i:1526375869;d:15.0863;i:1526366050;d:13.773300000000001;i:1526344449;d:12.9566;i:1526322886;d:10.7845;i:1526306401;d:17.998899999999999;}}' WHERE `device_id` = '52'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00531507s[0m][0m [0;32m##### [1;37mprinter01.hq.leaf.space [52] completed discovery modules at 2018-05-15 09:38:28[0;32m #####[0m [0m [0;32m o [1;37mDiscovery time [0m 13.9382 seconds [1;44;96m > $device_discovery_cache_keys[0m[44;36m /opt/observium/includes/discovery/functions.inc.php:422 [0m array( [5] => string(12) "discovery_os" [6] => string(7) "devices" [7] => string(7) "attribs" [8] => string(10) "port_index" [9] => string(4) "port" ) SQL[[0;33mDELETE FROM `observium_processes` WHERE `process_pid` = '21103' AND `process_name` = 'discovery.php' AND `device_id` = '52'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00435591s[0m][0m SQL[[0;33mSELECT * FROM `groups` ORDER BY `entity_type`[0m][0m ROWS[[0;32m4[0m] SQL RUNTIME[[0;32m0.00091195s[0m][0m SQL[[0;33mSELECT * FROM `groups_assoc`[0m][0m ROWS[[0;32m2[0m] SQL RUNTIME[[0;32m0.00084090s[0m][0m SQL[[0;33mSELECT device_id FROM `devices` WHERE( IFNULL(`devices`.`hostname`, "") LIKE '%leaf.space')[0m][0m ROWS[[0;32m23[0m] SQL RUNTIME[[0;32m0.00084209s[0m][0m SQL[[0;33mSELECT * FROM `group_table` WHERE `group_id` = '1'[0m][0m ROWS[[0;32m23[0m] SQL RUNTIME[[0;32m0.00073099s[0m][0m SQL[[0;33mSELECT device_id FROM `devices` WHERE( IFNULL(`devices`.`hostname`, "") LIKE '%italia1.gs.leaf.space')[0m][0m ROWS[[0;32m6[0m] SQL RUNTIME[[0;32m0.00097489s[0m][0m SQL[[0;33mSELECT * FROM `group_table` WHERE `group_id` = '2'[0m][0m ROWS[[0;32m6[0m] SQL RUNTIME[[0;32m0.00092196s[0m][0m SQL[[0;33mSELECT device_id FROM `devices` WHERE( IFNULL(`devices`.`hostname`, "") LIKE '%lituania1.gs.leaf.space')[0m][0m ROWS[[0;32m5[0m] SQL RUNTIME[[0;32m0.00101089s[0m][0m SQL[[0;33mSELECT * FROM `group_table` WHERE `group_id` = '3'[0m][0m ROWS[[0;32m5[0m] SQL RUNTIME[[0;32m0.00080299s[0m][0m SQL[[0;33mSELECT device_id FROM `devices` WHERE( IFNULL(`devices`.`hostname`, "") LIKE '%.hq.leaf.space')[0m][0m ROWS[[0;32m8[0m] SQL RUNTIME[[0;32m0.00085092s[0m][0m SQL[[0;33mSELECT * FROM `group_table` WHERE `group_id` = '4'[0m][0m ROWS[[0;32m8[0m] SQL RUNTIME[[0;32m0.00078702s[0m][0m SQL[[0;33mSELECT * FROM `alert_tests`[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00078893s[0m][0m SQL[[0;33mSELECT * FROM `alert_assoc`[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00096512s[0m][0m SQL[[0;33mSELECT COUNT(*) FROM `devices` AS d WHERE d.`device_id` = '52' AND IFNULL(d.`hostname`, "") LIKE '%leaf%'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00096107s[0m][0m SQL[[0;33mSELECT * FROM `alert_table` WHERE `device_id` = '52'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00756097s[0m][0m SQL[[0;33mSELECT * FROM `devices` WHERE `devices`.device_id = '52'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00139093s[0m][0m SQL[[0;33mSELECT * FROM `devices` WHERE `devices`.`device_id` = '52'[0m][0m ROWS[[0;32m1[0m] SQL RUNTIME[[0;32m0.00099301s[0m][0m [1;37m##### [1;37m[1;37mFinished discovery run at 2018-05-15 09:38:28[1;37m #####[0m [0m ./discovery.php: printer01.hq.leaf.space - 1 devices discovered in 14.12 secs SQL[[0;33mSELECT * FROM `observium_processes` WHERE `process_start` < '1526362694'[0m][0m ROWS[[0;31m0[0m] SQL RUNTIME[[0;32m0.00071406s[0m][0m NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output. [1;37m o [1;37mDevices Discovered [0m 1 [1;37m o [1;37mDiscovery Time [0m 14.12 secs [1;37m o [1;37mMemory usage [0m 14MB (peak: 14MB) [1;37m o [1;37mMySQL Usage [0m Cell[34/0.029s] Row[34/0.048s] Rows[81/0.087s] Column[0/0s] Update[5/0.009s] Insert[2/0.01s] Delete[2/0.006s] [1;37m o [1;37mRRDTool Usage [0m