DEBUG! Load class 'Console_Color2' from '/opt/observium/libs/pear/Console/Color2.php': OK CMD[/usr/bin/svn info /opt/observium]  CMD EXITCODE[0] CMD RUNTIME[0.0082s] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: http://svn.observium.org/svn/observium/trunk Relative URL: ^/observium/trunk Repository Root: http://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 9229 Node Kind: directory Schedule: normal Last Changed Author: mike Last Changed Rev: 9229 Last Changed Date: 2018-05-14 15:54:24 +0000 (Mon, 14 May 2018) ] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';] ROWS[1] SQL RUNTIME[0.00092506s] SQL[SELECT @@SESSION.sql_mode;] ROWS[1] SQL RUNTIME[0.00071788s] SQL[SET SESSION `sql_mode` = 'NO_ZERO_IN_DATE,NO_ZERO_DATE,ERROR_FOR_DIVISION_BY_ZERO,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION'] ROWS[0] SQL RUNTIME[0.00095606s] DB mode(s) disabled: STRICT_TRANS_TABLES, ONLY_FULL_GROUP_BY SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';] ROWS[1] SQL RUNTIME[0.00073195s] SQL[SELECT * FROM `config`] ROWS[13] SQL RUNTIME[0.00089312s] CMD[/bin/hostname -f]  CMD EXITCODE[0] CMD RUNTIME[0.0023s] STDOUT[ monitoring01.c.leafspace-183416.internal ] Load class 'Net_IPv6' from '/opt/observium/libs/pear/Net/IPv6.php': OK  ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 18.5.9229 http://www.observium.org  CMD[/opt/observium/scripts/distro]  Wrong process status! Issue in proc_get_status(), see: https://bugs.php.net/bug.php?id=69014 CMD EXITCODE[0] CMD RUNTIME[0.0088s] STDOUT[ Linux|4.13.0-31-generic|amd64|Ubuntu|16.04|kvm| ] CMD[/usr/bin/env python --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0021s] STDOUT[ Python 2.7.12 ] SQL[SELECT version();] ROWS[1] SQL RUNTIME[0.00087810s] CMD[/usr/bin/snmpget --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0023s] STDOUT[ NET-SNMP version: 5.7.3 ] CMD[/usr/bin/rrdtool --version | head -n1]  CMD EXITCODE[0] CMD RUNTIME[0.0068s] STDOUT[ RRDtool 1.5.5 Copyright by Tobias Oetiker ] CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}']  CMD EXITCODE[0] CMD RUNTIME[0.0365s] STDOUT[ Apache/2.4.18 ] CMD[date "+%:z"]  CMD EXITCODE[0] CMD RUNTIME[0.0019s] STDOUT[ +00:00 ] SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] ROWS[1] SQL RUNTIME[0.00089192s] SQL[SELECT @@SESSION.sql_mode;] ROWS[1] SQL RUNTIME[0.00066400s] SQL[SHOW VARIABLES LIKE 'character_set_connection'] ROWS[1] SQL RUNTIME[0.00240302s] ##### Software versions #####   o OS  Linux 4.13.0-31-generic [amd64] (Ubuntu 16.04)  o Apache  2.4.18  o PHP  7.0.30-0ubuntu0.16.04.1 (OPcache: DISABLED)  o Python  2.7.12  o MySQL  5.7.14-google-log (extension: mysqli 5.0.12-dev)  o SNMP  NET-SNMP 5.7.3  o RRDtool  1.5.5 ##### Memory Limit #####   o PHP  Unlimited ##### MySQL mode #####   o MySQL  NO_ZERO_IN_DATE,NO_ZERO_DATE,ERROR_FOR_DIVISION_BY_ZERO,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION ##### Charset info #####   o PHP  UTF-8  o MySQL  utf8 ##### Timezones info #####   o Date  Tuesday, 15-May-18 09:38:14 UTC  o PHP  +00:00  o MySQL  +00:00 SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';] ROWS[1] SQL RUNTIME[0.00074697s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] ROWS[1] SQL RUNTIME[0.00060201s] ##### Starting discovery run at 2018-05-15 09:38:14 #####  SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `device_id` = '52' AND `status` = '1' ORDER BY `last_discovered_timetaken` ASC] ROWS[1] SQL RUNTIME[0.00104499s] CMD[/usr/bin/snmpget -v2c -c 'public' -Pu -OQUst -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' sysObjectID.0 sysUpTime.0]  CMD EXITCODE[0] CMD RUNTIME[0.0556s] STDOUT[ sysObjectID.0 = enterprises.18334.1.2.1.2.1.131.2.8 sysUpTime.0 = 5939314 ] SNMP STATUS[TRUE] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '52'] ROWS[0] SQL RUNTIME[0.00117397s] SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '52'] ROWS[0] SQL RUNTIME[0.00104904s] CMD[/bin/ps -ww -o pid,ppid,uid,gid,tty,stat,time,lstart,args -p 21103]  CMD EXITCODE[0] CMD RUNTIME[0.0085s] STDOUT[ PID PPID UID GID TT STAT TIME STARTED COMMAND 21103 6436 0 0 pts/2 S+ 00:00:00 Tue May 15 09:38:13 2018 php ./discovery.php -h 52 -dd ] SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('21103','discovery.php','6436','0','php ./discovery.php -h 52 -dd','1526377093','52')] ROWS[1] SQL RUNTIME[0.00462103s]  > $device_discovery_cache_keys /opt/observium/includes/discovery/functions.inc.php:211  array( [0] => string(10) "db_version" [1] => string(9) "localhost" [2] => string(8) "versions" [3] => string(8) "timezone" [4] => string(14) "entity_attribs" ) ##### printer01.hq.leaf.space [52] #####   o OS Type  olivetti-printer  o OS Group  printer  o SNMP Version  v2c  o Last discovery  2018-05-15 09:18:04  o Last duration  15.09 seconds ##### Module Start: os #####  CMD[/usr/bin/snmpget -v2c -c 'public' -Pu -Ovq -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' sysDescr.0]  CMD EXITCODE[0] CMD RUNTIME[0.0265s] STDOUT[ Generic 25C-9 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -v2c -c 'public' -Pu -Ovqn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' sysObjectID.0]  CMD EXITCODE[0] CMD RUNTIME[0.0539s] STDOUT[ .1.3.6.1.4.1.18334.1.2.1.2.1.131.2.8 ] SNMP STATUS[TRUE] Load class 'cli\Table' from '/opt/observium/libs/cli/Table.php': OK Load class 'cli\Shell' from '/opt/observium/libs/cli/Shell.php': OK Load class 'cli\table\Renderer' from '/opt/observium/libs/cli/table/Renderer.php': OK Load class 'cli\table\Tabular' from '/opt/observium/libs/cli/table/Tabular.php': OK Load class 'cli\Table\Ascii' from '/opt/observium/libs/cli/table/Ascii.php': OK Load class 'cli\Colors' from '/opt/observium/libs/cli/Colors.php': OK Load class 'cli\Streams' from '/opt/observium/libs/cli/Streams.php': OK +-------------+--------------------------------------+ | OID | | +-------------+--------------------------------------+ | sysDescr | Generic 25C-9 | | sysObjectID | .1.3.6.1.4.1.18334.1.2.1.2.1.131.2.8 | +-------------+--------------------------------------+  o Detect OS matched (olivetti-printer: Olivetti Printer): +----------+---------------------+---------------+ | OID | Matched definition | | +----------+---------------------+---------------+ | sysDescr | /^Generic \w+-\w+$/ | Generic 25C-9 | +----------+---------------------+---------------+  o sysORID table  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' sysORID]  CMD EXITCODE[0] CMD RUNTIME[0.0595s] STDOUT[ .1.3.6.1.2.1.1.9.1.2 = No Such Object available on this agent at this OID ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUn, mib: 'SNMPv2-MIB', oid: 'sysORID', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.059541940689087 CMD[/usr/bin/snmptranslate -On -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'SNMPv2-MIB::sysORID']  CMD EXITCODE[0] CMD RUNTIME[0.0112s] STDOUT[ .1.3.6.1.2.1.1.9.1.2 ] SNMP TRANSLATE (CMD): 'SNMPv2-MIB::sysORID' -> '.1.3.6.1.2.1.1.9.1.2' CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' sysORDescr]  CMD EXITCODE[0] CMD RUNTIME[1.0644s] STDOUT[ sysORDescr = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'SNMPv2-MIB', oid: 'sysORDescr', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 1.0643630027771 SQL[DELETE FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '52' AND `attrib_type` = 'sysORID'] ROWS[0] SQL RUNTIME[0.00128603s]  o Duration  1.2643s ##### Module Start: ports #####   o Caching OIDs  ifDescr CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ifDescr]  CMD EXITCODE[0] CMD RUNTIME[1.0423s] STDOUT[ ifDescr.1 = Ethernet 10/100/1000 Base-T ifDescr.2 = Software Loopback ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] ifAlias CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ifAlias]  CMD EXITCODE[0] CMD RUNTIME[0.0515s] STDOUT[ ifAlias = No Such Object available on this agent at this OID ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'IF-MIB', oid: 'ifAlias', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.05146598815918 ifName CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ifName]  CMD EXITCODE[0] CMD RUNTIME[1.0539s] STDOUT[ ifName = No Such Object available on this agent at this OID ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'IF-MIB', oid: 'ifName', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 1.0538818836212 ifType CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ifType]  CMD EXITCODE[0] CMD RUNTIME[0.0407s] STDOUT[ ifType.1 = ethernetCsmacd ifType.2 = softwareLoopback ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] ifOperStatus CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ifOperStatus]  CMD EXITCODE[0] CMD RUNTIME[0.0413s] STDOUT[ ifOperStatus.1 = up ifOperStatus.2 = up ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '52' AND `attrib_type` = 'sysORID'] ROWS[0] SQL RUNTIME[0.00134301s] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '52'] ROWS[0] SQL RUNTIME[0.00078201s] SQL[SELECT * FROM `observium_attribs`] ROWS[20] SQL RUNTIME[0.00074697s]   /opt/observium/includes/discovery/ports.inc.php:36  array( [1] => array( [ifDescr] => string(27) "Ethernet 10/100/1000 Base-T" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) [2] => array( [ifDescr] => string(17) "Software Loopback" [ifType] => string(16) "softwareLoopback" [ifOperStatus] => string(2) "up" ) )  o Caching DB  SQL[SELECT * FROM `ports` WHERE `device_id` = '52'] ROWS[2] SQL RUNTIME[0.00102711s] 2 ports  o Discovering ports  .. ifIndex ifDescr ifName ifAlias ifType Oper Status Ignored 1 Ethernet 10/100/1000 Base-T ... ethernetCsmacd up no 2 Software Loopback ... softwareLoopback up no  o Duration  2.2544s ##### Module Start: ports-stack #####  SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '52'] ROWS[0] SQL RUNTIME[0.00086594s] CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ifStackStatus]  CMD EXITCODE[0] CMD RUNTIME[0.0516s] STDOUT[ ifStackStatus = No Such Object available on this agent at this OID ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'IF-MIB', oid: 'ifStackStatus', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.051576137542725  o Duration  0.0568s ##### Module Start: vlans #####  SQL[SELECT * FROM `vlans` WHERE `device_id` = '52';] ROWS[0] SQL RUNTIME[0.00140095s] SQL[SELECT * FROM `ports_vlans` WHERE `device_id` = '52';] ROWS[0] SQL RUNTIME[0.00074816s]  > $ports_vlans_db /opt/observium/includes/discovery/vlans.inc.php:33  array()  o Duration  0.0035s ##### Module Start: oids #####  SQL[SELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '52'] ROWS[0] SQL RUNTIME[0.00084114s] SQL[SELECT * FROM `oids` WHERE `oid_autodiscover` = '1'] ROWS[0] SQL RUNTIME[0.00068808s]  o Duration  0.0019s ##### Module Start: ip-addresses #####   o IP-MIB  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipAdEntIfIndex]  CMD EXITCODE[0] CMD RUNTIME[0.0429s] STDOUT[ ipAdEntIfIndex.10.0.0.102 = 1 ipAdEntIfIndex.127.0.0.1 = 2 ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipAdEntNetMask]  CMD EXITCODE[0] CMD RUNTIME[0.0373s] STDOUT[ ipAdEntNetMask.10.0.0.102 = 255.255.240.0 ipAdEntNetMask.127.0.0.1 = 255.0.0.0 ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipAddressIfIndex]  CMD EXITCODE[0] CMD RUNTIME[0.052s] STDOUT[ ipAddressIfIndex = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'IP-MIB', oid: 'ipAddressIfIndex', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.051959991455078  o IPV6-MIB  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUsb -m IPV6-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipv6AddrEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0282s] STDOUT[ ipv6AddrPfxLength.1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.1 = 128 ipv6AddrType.1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.1 = unknown ipv6AddrAnycastFlag.1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.1 = false ipv6AddrStatus.1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.1 = preferred ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE]  > $ip_data[$ip_version] /opt/observium/includes/discovery/ip-addresses.inc.php:28  array( [1] => array( [10.0.0.102] => array( [ifIndex] => string(1) "1" [ip] => string(10) "10.0.0.102" [mask] => string(13) "255.255.240.0" [type] => string(7) "unicast" ) ) [2] => array( [127.0.0.1] => array( [ifIndex] => string(1) "2" [ip] => string(9) "127.0.0.1" [mask] => string(9) "255.0.0.0" [type] => string(7) "unicast" ) ) ) SQL[SELECT * FROM `ipv4_addresses`  LEFT JOIN `ports` USING(`port_id`)  WHERE `device_id` = '52'] ROWS[2] SQL RUNTIME[0.00193191s] SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '52' AND `ifIndex` = '1' LIMIT 1] ROWS[1] SQL RUNTIME[0.00066710s] SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '2860'] ROWS[1] SQL RUNTIME[0.00083518s] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2860'] ROWS[0] SQL RUNTIME[0.00067711s] SQL[SELECT * FROM `devices` WHERE `device_id` = '52'] ROWS[1] SQL RUNTIME[0.00087595s] SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '52'] ROWS[24] SQL RUNTIME[0.00070786s] Load class 'Net_IPv4' from '/opt/observium/libs/pear/Net/IPv4.php': OK SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '10.0.0.0/20'] ROWS[1] SQL RUNTIME[0.00068808s] SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '52' AND `ifIndex` = '2' LIMIT 1] ROWS[1] SQL RUNTIME[0.00063109s] SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '2861'] ROWS[1] SQL RUNTIME[0.00097680s] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2861'] ROWS[0] SQL RUNTIME[0.00062394s] SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8'] ROWS[1] SQL RUNTIME[0.00064898s] SQL[SELECT * FROM `ipv4_addresses`  LEFT JOIN `ports` USING(`port_id`)  WHERE `device_id` = '52'] ROWS[2] SQL RUNTIME[0.00093389s]   /opt/observium/includes/discovery/ip-addresses.inc.php:28  array( [1] => array( [0000:0000:0000:0000:0000:0000:0000:0001] => array( [ifIndex] => int(1) [ip] => string(39) "0000:0000:0000:0000:0000:0000:0000:0001" [prefix] => string(3) "128" [origin] => string(7) "unknown" ) ) ) SQL[SELECT * FROM `ipv6_addresses`  LEFT JOIN `ports` USING(`port_id`)  WHERE `device_id` = '52'] ROWS[1] SQL RUNTIME[0.00105906s] SQL[SELECT `ipv6_network_id` FROM `ipv6_networks` WHERE `ipv6_network` = '0:0:0:0:0:0:0:1/128'] ROWS[1] SQL RUNTIME[0.00099587s] SQL[SELECT * FROM `ipv6_addresses`  LEFT JOIN `ports` USING(`port_id`)  WHERE `device_id` = '52'] ROWS[1] SQL RUNTIME[0.00093508s] ifIndex ifDescr IP: Version Address Network Origin 1 Ethernet 10/100/1000 Base-T IPv4 10.0.0.102/20 10.0.0.0/20 2 Software Loopback IPv4 127.0.0.1/8 127.0.0.0/8 1 Ethernet 10/100/1000 Base-T IPv6 ::1/128 0:0:0:0:0:0:0:1/128 unknown  o Changes  3 unchanged  o Duration  0.1945s ##### Module Start: processors #####   o UCD-SNMP-MIB  SQL[SELECT COUNT(*) FROM `processors` WHERE `device_id` = '52' AND `processor_type` != 'ucd-old'] ROWS[1] SQL RUNTIME[0.00068593s] CMD[/usr/bin/snmpget -v2c -c 'public' -Pu -OvQ -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ssCpuIdle.0]  CMD EXITCODE[0] CMD RUNTIME[0.0275s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpget, options: -OvQ, mib: 'UCD-SNMP-MIB', oid: 'ssCpuIdle.0', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.027470111846924  o HOST-RESOURCES-MIB  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' hrDevice]  CMD EXITCODE[0] CMD RUNTIME[1.1298s] STDOUT[ hrDeviceIndex.1 = 1 hrDeviceIndex.2 = 2 hrDeviceIndex.3 = 3 hrDeviceIndex.4 = 4 hrDeviceType.1 = hrDevicePrinter hrDeviceType.2 = hrDeviceOther hrDeviceType.3 = hrDeviceNetwork hrDeviceType.4 = hrDeviceDiskStorage hrDeviceDescr.1 = Generic 25C-9 hrDeviceDescr.2 = Generic 25C-9 hrDeviceDescr.3 = Ethernet 10/100/1000 Base-T hrDeviceDescr.4 = HDD hrDeviceID.1 = enterprises.18334.1.2.1.2.1.131.2.8 hrDeviceID.2 = enterprises.18334.1.2.1.2.1.131.2.8 hrDeviceID.3 = enterprises.18334.1.1.2.1.1.1.1 hrDeviceID.4 = enterprises.18334.1.1.3.1.1.1.2 hrDeviceStatus.1 = warning hrDeviceStatus.2 = running hrDeviceStatus.3 = running hrDeviceStatus.4 = running hrDeviceErrors.1 = 0 hrDeviceErrors.2 = 0 hrDeviceErrors.3 = 0 hrDeviceErrors.4 = 0 hrNetworkIfIndex.3 = 1 hrPrinterStatus.1 = idle hrPrinterDetectedErrorState.1 = "01 00 " ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' hrProcessorLoad]  CMD EXITCODE[0] CMD RUNTIME[0.0839s] STDOUT[ hrProcessorLoad = No Such Instance currently exists at this OID ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES', oid: 'hrProcessorLoad', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.083930969238281 SQL[SELECT * FROM `processors` WHERE `device_id` = '52'] ROWS[0] SQL RUNTIME[0.00137401s]  o Duration  1.2554s ##### Module Start: mempools #####   o UCD-SNMP-MIB  CMD[/usr/bin/snmpget -v2c -c 'public' -Pu -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0]  CMD EXITCODE[0] CMD RUNTIME[0.027s] STDOUT[ memTotalReal.0 = No Such Object available on this agent at this OID memAvailReal.0 = No Such Object available on this agent at this OID memBuffer.0 = No Such Object available on this agent at this OID memCached.0 = No Such Object available on this agent at this OID ] SNMP ERROR - device: 52, cmd: snmpget, options: -OQUs, mib: 'UCD-SNMP-MIB', oid: 'memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.026998043060303 SNMP STATUS[FALSE]  o HOST-RESOURCES-MIB  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' hrStorageEntry]  CMD EXITCODE[0] CMD RUNTIME[0.1137s] STDOUT[ hrStorageIndex.1 = 1 hrStorageIndex.2 = 2 hrStorageIndex.3 = 3 hrStorageIndex.4 = 4 hrStorageType.1 = hrStorageRam hrStorageType.2 = hrStorageFixedDisk hrStorageType.3 = hrStorageFlashMemory hrStorageType.4 = hrStorageOther hrStorageDescr.1 = RAM hrStorageDescr.2 = HDD hrStorageDescr.3 = SPIFlash hrStorageDescr.4 = eMMC hrStorageAllocationUnits.1 = 1048576 hrStorageAllocationUnits.2 = 1048576 hrStorageAllocationUnits.3 = 1048576 hrStorageAllocationUnits.4 = 1048576 hrStorageSize.1 = 2374 hrStorageSize.2 = 238454 hrStorageSize.3 = 2 hrStorageSize.4 = 4096 hrStorageUsed.1 = 2063 hrStorageUsed.2 = 107465 hrStorageUsed.3 = 2 hrStorageUsed.4 = 4096 hrStorageAllocationFailures.1 = 0 hrStorageAllocationFailures.2 = 0 hrStorageAllocationFailures.3 = 0 hrStorageAllocationFailures.4 = 0 ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] 52 -> 1, HOST-RESOURCES-MIB::, RAM, 1048576, 2374, 2063 SQL[SELECT * FROM `mempools` WHERE `device_id` = '52' AND `mempool_index` = '1' AND `mempool_mib` = 'HOST-RESOURCES-MIB'] ROWS[1] SQL RUNTIME[0.01676917s] 52 -> 4, HOST-RESOURCES-MIB::, eMMC, 1048576, 4096, 4096 SQL[SELECT * FROM `mempools` WHERE `device_id` = '52' AND `mempool_index` = '4' AND `mempool_mib` = 'HOST-RESOURCES-MIB'] ROWS[1] SQL RUNTIME[0.00156307s] SQL[SELECT * FROM `mempools` WHERE `device_id` = '52'] ROWS[2] SQL RUNTIME[0.00109482s] 1 -> HOST-RESOURCES-MIB 4 -> HOST-RESOURCES-MIB  > $valid['mempool'] /opt/observium/includes/discovery/mempools.inc.php:189  array( [HOST-RESOURCES-MIB] => array( [1] => int(1) [4] => int(1) ) )  o Changes  2 unchanged  o Duration  0.1695s ##### Module Start: inventory #####   o ENTITY-MIB  ENTITY-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'printer01.hq.leaf.space':'161' entPhysicalEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0927s] STDOUT[ entPhysicalEntry = No Such Object available on this agent at this OID ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB', oid: 'entPhysicalEntry', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.092744112014771  o HOST-RESOURCES-MIB  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' hrDeviceEntry]  CMD EXITCODE[0] CMD RUNTIME[0.1267s] STDOUT[ hrDeviceIndex.1 = 1 hrDeviceIndex.2 = 2 hrDeviceIndex.3 = 3 hrDeviceIndex.4 = 4 hrDeviceType.1 = hrDevicePrinter hrDeviceType.2 = hrDeviceOther hrDeviceType.3 = hrDeviceNetwork hrDeviceType.4 = hrDeviceDiskStorage hrDeviceDescr.1 = Generic 25C-9 hrDeviceDescr.2 = Generic 25C-9 hrDeviceDescr.3 = Ethernet 10/100/1000 Base-T hrDeviceDescr.4 = HDD hrDeviceID.1 = enterprises.18334.1.2.1.2.1.131.2.8 hrDeviceID.2 = enterprises.18334.1.2.1.2.1.131.2.8 hrDeviceID.3 = enterprises.18334.1.1.2.1.1.1.1 hrDeviceID.4 = enterprises.18334.1.1.3.1.1.1.2 hrDeviceStatus.1 = warning hrDeviceStatus.2 = running hrDeviceStatus.3 = running hrDeviceStatus.4 = running hrDeviceErrors.1 = 0 hrDeviceErrors.2 = 0 hrDeviceErrors.3 = 0 hrDeviceErrors.4 = 0 ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' hrProcessorEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0848s] STDOUT[ hrProcessorEntry = No Such Object available on this agent at this OID ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES', oid: 'hrProcessorEntry', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.084847927093506  > $hrDevices /opt/observium/includes/discovery/inventory/host-resources-mib.inc.php:20  array( [1] => array( [hrDeviceIndex] => string(1) "1" [hrDeviceType] => string(15) "hrDevicePrinter" [hrDeviceDescr] => string(13) "Generic 25C-9" [hrDeviceID] => string(35) "enterprises.18334.1.2.1.2.1.131.2.8" [hrDeviceStatus] => string(7) "warning" [hrDeviceErrors] => string(1) "0" ) [2] => array( [hrDeviceIndex] => string(1) "2" [hrDeviceType] => string(13) "hrDeviceOther" [hrDeviceDescr] => string(13) "Generic 25C-9" [hrDeviceID] => string(35) "enterprises.18334.1.2.1.2.1.131.2.8" [hrDeviceStatus] => string(7) "running" [hrDeviceErrors] => string(1) "0" ) [3] => array( [hrDeviceIndex] => string(1) "3" [hrDeviceType] => string(15) "hrDeviceNetwork" [hrDeviceDescr] => string(27) "Ethernet 10/100/1000 Base-T" [hrDeviceID] => string(31) "enterprises.18334.1.1.2.1.1.1.1" [hrDeviceStatus] => string(7) "running" [hrDeviceErrors] => string(1) "0" ) [4] => array( [hrDeviceIndex] => string(1) "4" [hrDeviceType] => string(19) "hrDeviceDiskStorage" [hrDeviceDescr] => string(3) "HDD" [hrDeviceID] => string(31) "enterprises.18334.1.1.3.1.1.1.2" [hrDeviceStatus] => string(7) "running" [hrDeviceErrors] => string(1) "0" ) ) SQL[SELECT COUNT(*) FROM `hrDevice` WHERE device_id = '52' AND hrDeviceIndex = '1'] ROWS[1] SQL RUNTIME[0.00137401s] SQL[UPDATE `hrDevice` set `hrDeviceType` ='hrDevicePrinter',`hrDeviceDescr` ='Generic 25C-9',`hrDeviceStatus` ='warning',`hrDeviceErrors` ='0',`hrProcessorLoad` =NULL WHERE device_id = '52' AND hrDeviceIndex = '1'] ROWS[0] SQL RUNTIME[0.00073695s] . SQL[SELECT COUNT(*) FROM `hrDevice` WHERE device_id = '52' AND hrDeviceIndex = '2'] ROWS[1] SQL RUNTIME[0.00067997s] SQL[UPDATE `hrDevice` set `hrDeviceType` ='hrDeviceOther',`hrDeviceDescr` ='Generic 25C-9',`hrDeviceStatus` ='running',`hrDeviceErrors` ='0',`hrProcessorLoad` =NULL WHERE device_id = '52' AND hrDeviceIndex = '2'] ROWS[0] SQL RUNTIME[0.00059891s] . SQL[SELECT COUNT(*) FROM `hrDevice` WHERE device_id = '52' AND hrDeviceIndex = '3'] ROWS[1] SQL RUNTIME[0.00055480s] SQL[UPDATE `hrDevice` set `hrDeviceType` ='hrDeviceNetwork',`hrDeviceDescr` ='Ethernet 10/100/1000 Base-T',`hrDeviceStatus` ='running',`hrDeviceErrors` ='0',`hrProcessorLoad` =NULL WHERE device_id = '52' AND hrDeviceIndex = '3'] ROWS[0] SQL RUNTIME[0.00067496s] . SQL[SELECT COUNT(*) FROM `hrDevice` WHERE device_id = '52' AND hrDeviceIndex = '4'] ROWS[1] SQL RUNTIME[0.00061202s] SQL[UPDATE `hrDevice` set `hrDeviceType` ='hrDeviceDiskStorage',`hrDeviceDescr` ='HDD',`hrDeviceStatus` ='running',`hrDeviceErrors` ='0',`hrProcessorLoad` =NULL WHERE device_id = '52' AND hrDeviceIndex = '4'] ROWS[0] SQL RUNTIME[0.00065494s] . SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '52'] ROWS[4] SQL RUNTIME[0.00068283s] SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '52'] ROWS[0] SQL RUNTIME[0.00067401s]  o Duration  0.3267s ##### Module Start: printersupplies #####   o Printer-MIB  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m Printer-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' prtMarkerSuppliesTable]  CMD EXITCODE[0] CMD RUNTIME[1.3648s] STDOUT[ prtMarkerSuppliesMarkerIndex.1.1 = 1 prtMarkerSuppliesMarkerIndex.1.2 = 1 prtMarkerSuppliesMarkerIndex.1.3 = 1 prtMarkerSuppliesMarkerIndex.1.4 = 1 prtMarkerSuppliesMarkerIndex.1.5 = 1 prtMarkerSuppliesMarkerIndex.1.6 = 1 prtMarkerSuppliesMarkerIndex.1.7 = 1 prtMarkerSuppliesMarkerIndex.1.8 = 1 prtMarkerSuppliesMarkerIndex.1.9 = 1 prtMarkerSuppliesMarkerIndex.1.10 = 1 prtMarkerSuppliesMarkerIndex.1.11 = 1 prtMarkerSuppliesMarkerIndex.1.12 = 1 prtMarkerSuppliesMarkerIndex.1.13 = 1 prtMarkerSuppliesMarkerIndex.1.14 = 1 prtMarkerSuppliesMarkerIndex.1.15 = 1 prtMarkerSuppliesMarkerIndex.1.16 = 1 prtMarkerSuppliesColorantIndex.1.1 = 1 prtMarkerSuppliesColorantIndex.1.2 = 2 prtMarkerSuppliesColorantIndex.1.3 = 3 prtMarkerSuppliesColorantIndex.1.4 = 4 prtMarkerSuppliesColorantIndex.1.5 = 1 prtMarkerSuppliesColorantIndex.1.6 = 1 prtMarkerSuppliesColorantIndex.1.7 = 2 prtMarkerSuppliesColorantIndex.1.8 = 2 prtMarkerSuppliesColorantIndex.1.9 = 3 prtMarkerSuppliesColorantIndex.1.10 = 3 prtMarkerSuppliesColorantIndex.1.11 = 4 prtMarkerSuppliesColorantIndex.1.12 = 4 prtMarkerSuppliesColorantIndex.1.13 = 0 prtMarkerSuppliesColorantIndex.1.14 = 0 prtMarkerSuppliesColorantIndex.1.15 = 0 prtMarkerSuppliesColorantIndex.1.16 = 0 prtMarkerSuppliesClass.1.1 = supplyThatIsConsumed prtMarkerSuppliesClass.1.2 = supplyThatIsConsumed prtMarkerSuppliesClass.1.3 = supplyThatIsConsumed prtMarkerSuppliesClass.1.4 = supplyThatIsConsumed prtMarkerSuppliesClass.1.5 = supplyThatIsConsumed prtMarkerSuppliesClass.1.6 = supplyThatIsConsumed prtMarkerSuppliesClass.1.7 = supplyThatIsConsumed prtMarkerSuppliesClass.1.8 = supplyThatIsConsumed prtMarkerSuppliesClass.1.9 = supplyThatIsConsumed prtMarkerSuppliesClass.1.10 = supplyThatIsConsumed prtMarkerSuppliesClass.1.11 = supplyThatIsConsumed prtMarkerSuppliesClass.1.12 = supplyThatIsConsumed prtMarkerSuppliesClass.1.13 = receptacleThatIsFilled prtMarkerSuppliesClass.1.14 = supplyThatIsConsumed prtMarkerSuppliesClass.1.15 = supplyThatIsConsumed prtMarkerSuppliesClass.1.16 = supplyThatIsConsumed prtMarkerSuppliesType.1.1 = toner prtMarkerSuppliesType.1.2 = toner prtMarkerSuppliesType.1.3 = toner prtMarkerSuppliesType.1.4 = toner prtMarkerSuppliesType.1.5 = opc prtMarkerSuppliesType.1.6 = developer prtMarkerSuppliesType.1.7 = opc prtMarkerSuppliesType.1.8 = developer prtMarkerSuppliesType.1.9 = opc prtMarkerSuppliesType.1.10 = developer prtMarkerSuppliesType.1.11 = opc prtMarkerSuppliesType.1.12 = developer prtMarkerSuppliesType.1.13 = wasteToner prtMarkerSuppliesType.1.14 = fuser prtMarkerSuppliesType.1.15 = transferUnit prtMarkerSuppliesType.1.16 = transferUnit prtMarkerSuppliesDescription.1.1 = "Toner (Cyan)" prtMarkerSuppliesDescription.1.2 = "Toner (Magenta)" prtMarkerSuppliesDescription.1.3 = "Toner (Yellow)" prtMarkerSuppliesDescription.1.4 = "Toner (Black)" prtMarkerSuppliesDescription.1.5 = "Drum Cartridge (Cyan)" prtMarkerSuppliesDescription.1.6 = "Developer Cartridge (Cyan)" prtMarkerSuppliesDescription.1.7 = "Drum Cartridge (Magenta)" prtMarkerSuppliesDescription.1.8 = "Developer Cartridge (Magenta)" prtMarkerSuppliesDescription.1.9 = "Drum Cartridge (Yellow)" prtMarkerSuppliesDescription.1.10 = "Developer Cartridge (Yellow)" prtMarkerSuppliesDescription.1.11 = "Drum Cartridge (Black)" prtMarkerSuppliesDescription.1.12 = "Developer Cartridge (Black)" prtMarkerSuppliesDescription.1.13 = "Waste Toner Box" prtMarkerSuppliesDescription.1.14 = "Fusing Unit" prtMarkerSuppliesDescription.1.15 = "Image Transfer Belt Unit" prtMarkerSuppliesDescription.1.16 = "Transfer Roller Unit" prtMarkerSuppliesSupplyUnit.1.1 = percent prtMarkerSuppliesSupplyUnit.1.2 = percent prtMarkerSuppliesSupplyUnit.1.3 = percent prtMarkerSuppliesSupplyUnit.1.4 = percent prtMarkerSuppliesSupplyUnit.1.5 = percent prtMarkerSuppliesSupplyUnit.1.6 = percent prtMarkerSuppliesSupplyUnit.1.7 = percent prtMarkerSuppliesSupplyUnit.1.8 = percent prtMarkerSuppliesSupplyUnit.1.9 = percent prtMarkerSuppliesSupplyUnit.1.10 = percent prtMarkerSuppliesSupplyUnit.1.11 = percent prtMarkerSuppliesSupplyUnit.1.12 = percent prtMarkerSuppliesSupplyUnit.1.13 = other prtMarkerSuppliesSupplyUnit.1.14 = percent prtMarkerSuppliesSupplyUnit.1.15 = percent prtMarkerSuppliesSupplyUnit.1.16 = percent prtMarkerSuppliesMaxCapacity.1.1 = 100 prtMarkerSuppliesMaxCapacity.1.2 = 100 prtMarkerSuppliesMaxCapacity.1.3 = 100 prtMarkerSuppliesMaxCapacity.1.4 = 100 prtMarkerSuppliesMaxCapacity.1.5 = 100 prtMarkerSuppliesMaxCapacity.1.6 = 100 prtMarkerSuppliesMaxCapacity.1.7 = 100 prtMarkerSuppliesMaxCapacity.1.8 = 100 prtMarkerSuppliesMaxCapacity.1.9 = 100 prtMarkerSuppliesMaxCapacity.1.10 = 100 prtMarkerSuppliesMaxCapacity.1.11 = 100 prtMarkerSuppliesMaxCapacity.1.12 = 100 prtMarkerSuppliesMaxCapacity.1.13 = -2 prtMarkerSuppliesMaxCapacity.1.14 = 100 prtMarkerSuppliesMaxCapacity.1.15 = 100 prtMarkerSuppliesMaxCapacity.1.16 = 100 prtMarkerSuppliesLevel.1.1 = 100 prtMarkerSuppliesLevel.1.2 = 100 prtMarkerSuppliesLevel.1.3 = 100 prtMarkerSuppliesLevel.1.4 = 100 prtMarkerSuppliesLevel.1.5 = 99 prtMarkerSuppliesLevel.1.6 = 99 prtMarkerSuppliesLevel.1.7 = 99 prtMarkerSuppliesLevel.1.8 = 99 prtMarkerSuppliesLevel.1.9 = 99 prtMarkerSuppliesLevel.1.10 = 99 prtMarkerSuppliesLevel.1.11 = 99 prtMarkerSuppliesLevel.1.12 = 99 prtMarkerSuppliesLevel.1.13 = -3 prtMarkerSuppliesLevel.1.14 = 99 prtMarkerSuppliesLevel.1.15 = 99 prtMarkerSuppliesLevel.1.16 = 99 ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m Printer-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' prtMarkerColorantTable]  CMD EXITCODE[0] CMD RUNTIME[0.0593s] STDOUT[ prtMarkerColorantMarkerIndex.1.1 = 1 prtMarkerColorantMarkerIndex.1.2 = 1 prtMarkerColorantMarkerIndex.1.3 = 1 prtMarkerColorantMarkerIndex.1.4 = 1 prtMarkerColorantRole.1.1 = process prtMarkerColorantRole.1.2 = process prtMarkerColorantRole.1.3 = process prtMarkerColorantRole.1.4 = process prtMarkerColorantValue.1.1 = "cyan" prtMarkerColorantValue.1.2 = "magenta" prtMarkerColorantValue.1.3 = "yellow" prtMarkerColorantValue.1.4 = "black" prtMarkerColorantTonality.1.1 = 256 prtMarkerColorantTonality.1.2 = 256 prtMarkerColorantTonality.1.3 = 256 prtMarkerColorantTonality.1.4 = 256 ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.1'] ROWS[1] SQL RUNTIME[0.00129390s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.1'] ROWS[1] SQL RUNTIME[0.00080395s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.2'] ROWS[1] SQL RUNTIME[0.00080490s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.2'] ROWS[1] SQL RUNTIME[0.00077891s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.3'] ROWS[1] SQL RUNTIME[0.00062203s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.3'] ROWS[1] SQL RUNTIME[0.00064397s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.4'] ROWS[1] SQL RUNTIME[0.00058413s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.4'] ROWS[1] SQL RUNTIME[0.00069380s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.5'] ROWS[1] SQL RUNTIME[0.00068998s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.5'] ROWS[1] SQL RUNTIME[0.00073791s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.6'] ROWS[1] SQL RUNTIME[0.00062895s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.6'] ROWS[1] SQL RUNTIME[0.00061393s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.7'] ROWS[1] SQL RUNTIME[0.00061178s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.7'] ROWS[1] SQL RUNTIME[0.00078917s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.8'] ROWS[1] SQL RUNTIME[0.00068998s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.8'] ROWS[1] SQL RUNTIME[0.00064516s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.9'] ROWS[1] SQL RUNTIME[0.00060296s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.9'] ROWS[1] SQL RUNTIME[0.00063396s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.10'] ROWS[1] SQL RUNTIME[0.00067496s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.10'] ROWS[1] SQL RUNTIME[0.00067496s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.11'] ROWS[1] SQL RUNTIME[0.00066900s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.11'] ROWS[1] SQL RUNTIME[0.00063801s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.12'] ROWS[1] SQL RUNTIME[0.00058007s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.12'] ROWS[1] SQL RUNTIME[0.00073910s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.13'] ROWS[1] SQL RUNTIME[0.00069714s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.13'] ROWS[1] SQL RUNTIME[0.00071383s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.14'] ROWS[1] SQL RUNTIME[0.00063086s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.14'] ROWS[1] SQL RUNTIME[0.00068283s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.15'] ROWS[1] SQL RUNTIME[0.00064087s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.15'] ROWS[1] SQL RUNTIME[0.00073981s] SQL[SELECT COUNT(`supply_id`) FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.16'] ROWS[1] SQL RUNTIME[0.00062203s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_index` = '1.16'] ROWS[1] SQL RUNTIME[0.00073385s] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52'] ROWS[16] SQL RUNTIME[0.00074100s] ................  o Changes  16 unchanged  o Duration  1.4598s ##### Module Start: sensors #####   o Printer-MIB  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m Printer-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' prtMarkerEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0671s] STDOUT[ prtMarkerMarkTech.1.1 = electrophotographicLaser prtMarkerCounterUnit.1.1 = impressions prtMarkerLifeCount.1.1 = 38 prtMarkerPowerOnCount.1.1 = 20 prtMarkerProcessColorants.1.1 = 4 prtMarkerSpotColorants.1.1 = 0 prtMarkerAddressabilityUnit.1.1 = tenThousandthsOfInches prtMarkerAddressabilityFeedDir.1.1 = 600 prtMarkerAddressabilityXFeedDir.1.1 = 1800 prtMarkerNorthMargin.1.1 = 1667 prtMarkerSouthMargin.1.1 = 1181 prtMarkerWestMargin.1.1 = 1181 prtMarkerEastMargin.1.1 = 1181 prtMarkerStatus.1.1 = 0 ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m Printer-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' prtMarkerSuppliesDescription]  CMD EXITCODE[0] CMD RUNTIME[0.0836s] STDOUT[ prtMarkerSuppliesDescription.1.1 = "Toner (Cyan)" prtMarkerSuppliesDescription.1.2 = "Toner (Magenta)" prtMarkerSuppliesDescription.1.3 = "Toner (Yellow)" prtMarkerSuppliesDescription.1.4 = "Toner (Black)" prtMarkerSuppliesDescription.1.5 = "Drum Cartridge (Cyan)" prtMarkerSuppliesDescription.1.6 = "Developer Cartridge (Cyan)" prtMarkerSuppliesDescription.1.7 = "Drum Cartridge (Magenta)" prtMarkerSuppliesDescription.1.8 = "Developer Cartridge (Magenta)" prtMarkerSuppliesDescription.1.9 = "Drum Cartridge (Yellow)" prtMarkerSuppliesDescription.1.10 = "Developer Cartridge (Yellow)" prtMarkerSuppliesDescription.1.11 = "Drum Cartridge (Black)" prtMarkerSuppliesDescription.1.12 = "Developer Cartridge (Black)" prtMarkerSuppliesDescription.1.13 = "Waste Toner Box" prtMarkerSuppliesDescription.1.14 = "Fusing Unit" prtMarkerSuppliesDescription.1.15 = "Image Transfer Belt Unit" prtMarkerSuppliesDescription.1.16 = "Transfer Roller Unit" ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '52' AND `supply_mib` = 'jetdirect' AND `supply_index` = '1.1'] ROWS[1] SQL RUNTIME[0.00136399s] Discover sensor: counter, printer01.hq.leaf.space, .1.3.6.1.2.1.43.10.2.1.4.1.1, 1.1, Printer-MIB-prtMarkerLifeCount, Total Printed Impressions, SCALE: 1, LIMITS: (, , , ), CURRENT: 38, snmp, , SQL[SELECT COUNT(`sensor_id`) FROM `sensors`  WHERE `poller_type`= 'snmp' AND `sensor_class` = 'counter' AND `device_id` = '52' AND `sensor_type` = 'Printer-MIB-prtMarkerLifeCount' AND `sensor_index` = '1.1'] ROWS[1] SQL RUNTIME[0.00092697s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'counter' AND `device_id` = '52' AND `sensor_type` = 'Printer-MIB-prtMarkerLifeCount' AND `sensor_index` = '1.1'] ROWS[1] SQL RUNTIME[0.00083899s] Compare float numbers: "1" with "1", epsilon: "1.0E-5", comparision: "0 < 1.0E-5", numbers: SAME Compare float numbers: "0" with "0", epsilon: "1.0E-5", comparision: "0 < 1.0E-5", numbers: SAME SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '450' AND `attrib_type` = 'sensor_addition'] ROWS[0] SQL RUNTIME[0.00076580s] .Discover sensor: counter, printer01.hq.leaf.space, .1.3.6.1.2.1.43.10.2.1.5.1.1, 1.1, Printer-MIB-prtMarkerPowerOnCount, PowerOn Printed Impressions - Toner (Cyan), SCALE: 1, LIMITS: (, , , ), CURRENT: 20, snmp, , SQL[SELECT COUNT(`sensor_id`) FROM `sensors`  WHERE `poller_type`= 'snmp' AND `sensor_class` = 'counter' AND `device_id` = '52' AND `sensor_type` = 'Printer-MIB-prtMarkerPowerOnCount' AND `sensor_index` = '1.1'] ROWS[1] SQL RUNTIME[0.00064993s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'counter' AND `device_id` = '52' AND `sensor_type` = 'Printer-MIB-prtMarkerPowerOnCount' AND `sensor_index` = '1.1'] ROWS[1] SQL RUNTIME[0.00087094s] Compare float numbers: "1" with "1", epsilon: "1.0E-5", comparision: "0 < 1.0E-5", numbers: SAME Compare float numbers: "0" with "0", epsilon: "1.0E-5", comparision: "0 < 1.0E-5", numbers: SAME SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '451' AND `attrib_type` = 'sensor_addition'] ROWS[0] SQL RUNTIME[0.00075603s] .  o ENTITY-SENSOR-MIB  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' entPhySensorValue]  CMD EXITCODE[0] CMD RUNTIME[0.0523s] STDOUT[ entPhySensorValue = No Such Object available on this agent at this OID ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'ENTITY-MIB:ENTITY-SENSOR-MIB', oid: 'entPhySensorValue', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.052258968353271  > $valid['sensor'] /opt/observium/includes/discovery/sensors.inc.php:699  array( [counter] => array( [Printer-MIB-prtMarkerLifeCount] => array( [1.1] => int(1) ) [Printer-MIB-prtMarkerPowerOnCount] => array( [1.1] => int(1) ) ) ) SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00132298s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00073099s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00062394s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00067997s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00077200s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00066209s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00080919s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'charge' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00063896s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00078702s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'energy' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00074792s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00061202s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00066900s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00060105s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00064898s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00070906s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00066614s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00074601s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00065708s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00065494s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00063705s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00059295s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00070906s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00071812s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00060892s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00064397s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00078821s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00066400s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00064898s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00069094s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '52' AND `sensor_class` = 'counter' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] ROWS[2] SQL RUNTIME[0.00073481s]  > $valid['status'] /opt/observium/includes/discovery/sensors.inc.php:705  array() SQL[SELECT * FROM `status` WHERE `device_id` = '52' AND `poller_type` = 'snmp' AND `status_deleted` = '0'] ROWS[0] SQL RUNTIME[0.00070596s]  o Duration  0.2498s ##### Module Start: storage #####   o UCD-SNMP-MIB  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' dskEntry]  CMD EXITCODE[0] CMD RUNTIME[0.06s] STDOUT[ dskEntry = No Such Object available on this agent at this OID ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'UCD-SNMP-MIB', oid: 'dskEntry', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.06002402305603  o HOST-RESOURCES-MIB  52 -> 2, hrStorageFixedDisk, HOST-RESOURCES-MIB, HDD, 1048576, 250037141504, 112685219840, 0 SQL[SELECT * FROM `storage` WHERE `device_id` = '52' AND `storage_index` = '2' AND `storage_mib` = 'host-resources-mib'] ROWS[1] SQL RUNTIME[0.00124002s]  > $update /opt/observium/includes/discovery/functions.inc.php:1274  array() 52 -> 3, hrStorageFlashMemory, HOST-RESOURCES-MIB, SPIFlash, 1048576, 2097152, 2097152, 0 SQL[SELECT * FROM `storage` WHERE `device_id` = '52' AND `storage_index` = '3' AND `storage_mib` = 'host-resources-mib'] ROWS[1] SQL RUNTIME[0.00076699s]   /opt/observium/includes/discovery/functions.inc.php:1274  array()  > $valid['storage'] /opt/observium/includes/discovery/storage.inc.php:19  array( [host-resources-mib] => array( [2] => string(3) "HDD" [3] => string(8) "SPIFlash" ) ) SQL[SELECT * FROM `storage` WHERE `device_id` = '52'] ROWS[2] SQL RUNTIME[0.00141692s] 2 -> host-resources-mib 3 -> host-resources-mib  > $valid[$module] /opt/observium/includes/discovery/storage.inc.php:40  array( [host-resources-mib] => array( [2] => string(3) "HDD" [3] => string(8) "SPIFlash" ) )  o Changes  2 unchanged  o Duration  0.0708s ##### Module Start: neighbours #####   o LLDP-MIB  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' lldpRemChassisIdSubtype]  CMD EXITCODE[0] CMD RUNTIME[0.0569s] STDOUT[ lldpRemChassisIdSubtype = No Such Object available on this agent at this OID ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'LLDP-MIB', oid: 'lldpRemChassisIdSubtype', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.056887865066528   /opt/observium/includes/discovery/neighbours/lldp-mib.inc.php:28  array() SQL[SELECT * FROM `neighbours` LEFT JOIN `ports` USING(`port_id`) WHERE `device_id` = '52'] ROWS[0] SQL RUNTIME[0.00112700s]  o Duration  0.0622s ##### Module Start: arp-table #####  SQL[SELECT port_id, ifIndex FROM ports WHERE device_id = '52' GROUP BY port_id] ROWS[2] SQL RUNTIME[0.00073409s] CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipNetToPhysicalPhysAddress]  CMD EXITCODE[0] CMD RUNTIME[0.0505s] STDOUT[ ipNetToPhysicalPhysAddress No Such Object available on this agent at this OID ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OXqs, mib: 'IP-MIB', oid: 'ipNetToPhysicalPhysAddress', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.050471782684326 CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OXqs -m IPV6-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipv6NetToMediaPhysAddress]  CMD EXITCODE[0] CMD RUNTIME[6.0364s] STDOUT[ ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' ipNetToMediaPhysAddress]  CMD EXITCODE[0] CMD RUNTIME[0.307s] STDOUT[ ipNetToMediaPhysAddress[1][10.0.0.1] e4:8d:8c:f:15:9b ipNetToMediaPhysAddress[1][10.0.0.3] 70:4f:57:37:6c:db ipNetToMediaPhysAddress[1][10.0.0.101] 0:4:56:a9:5f:a ipNetToMediaPhysAddress[1][10.0.0.200] 4c:cc:6a:6e:45:44 ipNetToMediaPhysAddress[1][10.0.2.2] 64:0:6a:84:ce:ae ipNetToMediaPhysAddress[1][10.0.2.3] 64:0:6a:84:cf:42 ipNetToMediaPhysAddress[1][10.0.2.7] d8:9e:f3:74:58:b7 ipNetToMediaPhysAddress[1][10.0.2.8] d8:9e:f3:75:4:ac ipNetToMediaPhysAddress[1][10.0.2.100] 78:4f:43:5c:13:5a ipNetToMediaPhysAddress[1][10.0.2.101] f8:da:c:4c:10:47 ipNetToMediaPhysAddress[1][10.0.5.76] 0:4:56:a9:5d:e0 ipNetToMediaPhysAddress[1][10.0.5.159] 64:0:6a:be:e2:d8 ipNetToMediaPhysAddress[1][10.0.5.160] bc:30:5b:ee:56:f0 ipNetToMediaPhysAddress[1][169.254.229.29] f8:da:c:4c:10:47 ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[TRUE] Used IP-MIB::ipNetToMediaPhysAddress SQL[SELECT mac_id, mac_address, ip_address, ip_version, ifIndex FROM ip_mac AS M  LEFT JOIN ports AS I ON M.port_id = I.port_id  WHERE I.device_id = '52'] ROWS[13] SQL RUNTIME[0.00207281s] ....... SQL[INSERT INTO `ip_mac` (`port_id`,`mac_address`,`ip_address`,`ip_version`) VALUES ('2860','d89ef37504ac','10.0.2.8','4')] ROWS[1] SQL RUNTIME[0.00516701s] Added MAC address d8:9e:f3:75:04:ac for 10.0.2.8 +......  o Duration  6.4156s ##### Module Start: junose-atm-vp #####   o Duration  0.0007s ##### Module Start: bgp-peers #####   o Duration  0.0025s ##### Module Start: mac-accounting #####   o Duration  0.0002s Module [ cisco-vrf ] is in the blacklist for printer ##### Module Start: sla #####   o DISMAN-PING-MIB  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m DISMAN-PING-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' pingCtlEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0568s] STDOUT[ pingCtlEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'DISMAN-PING-MIB', oid: 'pingCtlEntry', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.056824922561646  > $sla_table /opt/observium/includes/discovery/sla.inc.php:22  null SQL[SELECT * FROM `slas` WHERE `device_id` = '52'] ROWS[0] SQL RUNTIME[0.00121403s]   /opt/observium/includes/discovery/sla.inc.php:40  array()  o Duration  0.0637s ##### Module Start: lsp #####   o Duration  0.0001s ##### Module Start: pseudowires #####  SQL[SELECT * FROM `pseudowires` WHERE `device_id` = '52'] ROWS[0] SQL RUNTIME[0.00093102s]  o Duration  0.0016s ##### Module Start: virtual-machines #####   o Duration  0.0005s Module [ cisco-cbqos ] is in the blacklist for printer ##### Module Start: ucd-diskio #####  CMD[/usr/bin/snmpbulkwalk -v2c -c 'public' -Pu -OQUs -m UCD-DISKIO-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer01.hq.leaf.space':'161' diskIOEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0516s] STDOUT[ diskIOEntry = No Such Object available on this agent at this OID ] All quotes stripped from snmp output, also for indexes and values! SNMP STATUS[FALSE] SNMP ERROR - device: 52, cmd: snmpwalk, options: -OQUs, mib: 'UCD-DISKIO-MIB', oid: 'diskIOEntry', cmd exitcode: 0, snmp error code: #1000, reason: 'Failed response', runtime: 0.05161714553833 SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '52'] ROWS[0] SQL RUNTIME[0.00113797s]  o Duration  0.057s ##### Module Start: wifi #####  SQL[SELECT * FROM `wifi_radios` WHERE `device_id` = '52'] ROWS[0] SQL RUNTIME[0.00093603s] SQL[SELECT * FROM `wifi_wlans` WHERE `device_id` = '52'] ROWS[0] SQL RUNTIME[0.00086403s] SQL[SELECT * FROM `wifi_aps` WHERE `device_id` = '52'] ROWS[0] SQL RUNTIME[0.00085282s]  o Duration  0.0036s ##### Module Start: p2p-radios #####   o Duration  0.0001s ##### Module Start: graphs #####   o Duration  0.0004s Module [ services ] disabled globally. Module [ raid ] disabled globally. SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '52';] ROWS[1] SQL RUNTIME[0.00104189s]  > $old_device_state['discovery_history'] /opt/observium/includes/discovery/functions.inc.php:388  array( [1526375869] => double(15.0863) [1526366050] => double(13.7733) [1526344449] => double(12.9566) [1526322886] => double(10.7845) [1526306401] => double(17.9989) )  > $discovery_history /opt/observium/includes/discovery/functions.inc.php:391  array( [1526377094] => double(13.9382) [1526375869] => double(15.0863) [1526366050] => double(13.7733) [1526344449] => double(12.9566) [1526322886] => double(10.7845) [1526306401] => double(17.9989) ) SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='printer',`last_discovered_timetaken` ='13.9382',`force_discovery` ='0',`device_state` ='a:3:{s:15:\"poller_mod_perf\";a:27:{s:6:\"system\";d:1.5879000000000001;s:2:\"os\";d:0.83699999999999997;s:7:\"sensors\";d:0.47070000000000001;s:6:\"status\";d:0.0011000000000000001;s:10:\"processors\";d:0.0025999999999999999;s:8:\"mempools\";d:0.31659999999999999;s:7:\"storage\";d:0.0129;s:8:\"netstats\";d:1.4885999999999999;s:6:\"hr-mib\";d:0.12540000000000001;s:7:\"ucd-mib\";d:0.14480000000000001;s:13:\"ipSystemStats\";d:0.2306;s:5:\"ports\";d:0.93300000000000005;s:9:\"bgp-peers\";d:0.0030000000000000001;s:15:\"printersupplies\";d:4.1532999999999998;s:10:\"ucd-diskio\";d:0.0032000000000000002;s:4:\"wifi\";d:0.00020000000000000001;s:10:\"p2p-radios\";d:0.0132;s:4:\"ospf\";d:0.00050000000000000001;s:3:\"sla\";d:0.0015;s:11:\"pseudowires\";d:0.0040000000000000001;s:14:\"mac-accounting\";d:0.0091999999999999998;s:12:\"loadbalancer\";d:0.00040000000000000002;s:15:\"entity-physical\";d:0.00020000000000000001;s:12:\"applications\";d:0.0022000000000000001;s:9:\"fdb-table\";d:0.22259999999999999;s:6:\"graphs\";d:0.00040000000000000002;s:4:\"oids\";d:0.0030000000000000001;}s:14:\"poller_history\";a:236:{i:1526376904;d:12.1051;i:1526376605;d:18.412199999999999;i:1526376305;d:11.5501;i:1526376005;d:12.407500000000001;i:1526375705;d:17.484999999999999;i:1526375405;d:13.962999999999999;i:1526375106;d:12.956;i:1526374805;d:21.3108;i:1526374505;d:16.272400000000001;i:1526374205;d:15.905099999999999;i:1526373905;d:15.2522;i:1526373605;d:13.5852;i:1526373305;d:11.9674;i:1526373005;d:10.890599999999999;i:1526372705;d:11.3035;i:1526372404;d:17.100000000000001;i:1526372104;d:18.746300000000002;i:1526371805;d:17.157299999999999;i:1526371504;d:13.1174;i:1526371205;d:17.206399999999999;i:1526370905;d:15.4923;i:1526370605;d:13.1305;i:1526370306;d:11.503;i:1526370005;d:14.3498;i:1526369705;d:16.347000000000001;i:1526369405;d:17.901499999999999;i:1526369105;d:13.316599999999999;i:1526368804;d:15.5297;i:1526368505;d:16.3188;i:1526368205;d:15.7143;i:1526367905;d:17.190200000000001;i:1526367604;d:19.297799999999999;i:1526367306;d:18.284700000000001;i:1526367005;d:15.2506;i:1526366705;d:14.44;i:1526366405;d:12.0867;i:1526366105;d:16.135899999999999;i:1526365805;d:11.339;i:1526365506;d:16.481100000000001;i:1526365205;d:12.1479;i:1526364905;d:14.555400000000001;i:1526364605;d:14.640000000000001;i:1526364305;d:17.093599999999999;i:1526364004;d:13.743600000000001;i:1526363705;d:18.050899999999999;i:1526363405;d:11.6281;i:1526363105;d:12.4727;i:1526362804;d:13.668699999999999;i:1526362505;d:16.313400000000001;i:1526362205;d:14.5365;i:1526361905;d:15.922700000000001;i:1526361605;d:14.3049;i:1526361305;d:10.450200000000001;i:1526361005;d:11.308199999999999;i:1526360705;d:19.616800000000001;i:1526360405;d:17.132400000000001;i:1526360105;d:12.1012;i:1526359805;d:14.23;i:1526359505;d:17.5488;i:1526359205;d:11.397500000000001;i:1526358905;d:14.823499999999999;i:1526358605;d:12.142300000000001;i:1526358305;d:14.411099999999999;i:1526358005;d:11.3904;i:1526357705;d:14.9223;i:1526357404;d:12.7827;i:1526357105;d:16.279599999999999;i:1526356805;d:14.536799999999999;i:1526356505;d:12.984500000000001;i:1526356205;d:16.8432;i:1526355905;d:12.1945;i:1526355605;d:10.656700000000001;i:1526355305;d:14.285399999999999;i:1526355005;d:16.9894;i:1526354705;d:12.8903;i:1526354405;d:15.753;i:1526354105;d:13.888400000000001;i:1526353805;d:12.302;i:1526353505;d:11.434200000000001;i:1526353205;d:11.786899999999999;i:1526352905;d:12.736800000000001;i:1526352605;d:11.646000000000001;i:1526352305;d:14.3141;i:1526352005;d:15.9626;i:1526351706;d:15.6332;i:1526351405;d:16.217500000000001;i:1526351105;d:15.963800000000001;i:1526350805;d:19.168099999999999;i:1526350504;d:15.7841;i:1526350204;d:15.9526;i:1526349905;d:16.319800000000001;i:1526349605;d:15.128399999999999;i:1526349305;d:11.909000000000001;i:1526349005;d:15.1516;i:1526348704;d:12.286300000000001;i:1526348405;d:16.048300000000001;i:1526348104;d:15.3292;i:1526347805;d:16.3797;i:1526347504;d:17.375299999999999;i:1526347205;d:13.1403;i:1526346905;d:17.333100000000002;i:1526346605;d:10.985799999999999;i:1526346305;d:15.2759;i:1526346005;d:14.3919;i:1526345705;d:10.383800000000001;i:1526345405;d:14.526400000000001;i:1526345105;d:16.248899999999999;i:1526344805;d:16.146100000000001;i:1526344506;d:12.958600000000001;i:1526344206;d:12.1821;i:1526343905;d:13.2066;i:1526343606;d:14.0418;i:1526343305;d:14.2896;i:1526343005;d:16.834800000000001;i:1526342705;d:18.266400000000001;i:1526342405;d:15.592700000000001;i:1526342105;d:11.6577;i:1526341805;d:16.041599999999999;i:1526341505;d:12.7509;i:1526341205;d:11.8164;i:1526340905;d:16.854099999999999;i:1526340605;d:12.947699999999999;i:1526340305;d:11.982100000000001;i:1526340005;d:17.996099999999998;i:1526339705;d:17.577400000000001;i:1526339405;d:17.638400000000001;i:1526339105;d:13.919499999999999;i:1526338805;d:18.907;i:1526338505;d:14.2447;i:1526338205;d:14.700799999999999;i:1526337905;d:14.1858;i:1526337605;d:13.5931;i:1526337305;d:17.133299999999998;i:1526337005;d:12.571099999999999;i:1526336706;d:13.2575;i:1526336405;d:15.975899999999999;i:1526336105;d:17.888000000000002;i:1526335805;d:13.7074;i:1526335505;d:18.2105;i:1526335205;d:14.6595;i:1526334905;d:12.251899999999999;i:1526334605;d:14.273899999999999;i:1526334305;d:13.248200000000001;i:1526334005;d:14.773899999999999;i:1526333705;d:10.6995;i:1526333405;d:12.0206;i:1526333105;d:13.1746;i:1526332805;d:14.9795;i:1526332505;d:12.070600000000001;i:1526332205;d:11.630699999999999;i:1526331905;d:14.648999999999999;i:1526331605;d:15.286799999999999;i:1526331305;d:14.239800000000001;i:1526331005;d:12.976599999999999;i:1526330705;d:14.764799999999999;i:1526330405;d:17.330200000000001;i:1526330105;d:15.3689;i:1526329805;d:16.1846;i:1526329505;d:12.6465;i:1526329205;d:12.960699999999999;i:1526328905;d:17.167200000000001;i:1526328605;d:13.725300000000001;i:1526328306;d:15.952500000000001;i:1526328005;d:15.353199999999999;i:1526327705;d:12.0761;i:1526327405;d:16.030000000000001;i:1526327105;d:15.224299999999999;i:1526326806;d:17.9163;i:1526326506;d:13.2439;i:1526326205;d:12.5313;i:1526325905;d:14.453200000000001;i:1526325605;d:17.945499999999999;i:1526325305;d:14.6938;i:1526325006;d:20.107500000000002;i:1526324706;d:14.5945;i:1526324405;d:13.8718;i:1526324105;d:20.3657;i:1526323805;d:14.8916;i:1526323505;d:13.8345;i:1526323205;d:16.129899999999999;i:1526322905;d:13.1242;i:1526322605;d:16.2315;i:1526322306;d:13.877599999999999;i:1526322005;d:11.253;i:1526321706;d:13.172700000000001;i:1526321405;d:14.582599999999999;i:1526321106;d:17.8292;i:1526320805;d:15.4457;i:1526320505;d:17.921399999999998;i:1526320206;d:17.193000000000001;i:1526319905;d:12.027100000000001;i:1526319605;d:14.818099999999999;i:1526319306;d:13.1325;i:1526319005;d:12.2872;i:1526318705;d:14.8878;i:1526318406;d:15.705;i:1526318105;d:14.186400000000001;i:1526317812;d:15.832599999999999;i:1526317505;d:46.1464;i:1526317205;d:13.8063;i:1526316905;d:16.542899999999999;i:1526316605;d:12.2072;i:1526316305;d:12.939;i:1526316005;d:15.5909;i:1526315705;d:13.2255;i:1526315405;d:14.7119;i:1526315105;d:15.772500000000001;i:1526314805;d:16.9711;i:1526314505;d:13.629300000000001;i:1526314205;d:16.9665;i:1526313906;d:13.9666;i:1526313605;d:12.7348;i:1526313305;d:13.137700000000001;i:1526313006;d:13.175800000000001;i:1526312705;d:13.4872;i:1526312405;d:19.6236;i:1526312105;d:15.668699999999999;i:1526311805;d:13.8835;i:1526311505;d:11.6706;i:1526311206;d:15.571899999999999;i:1526310905;d:17.77;i:1526310605;d:11.7826;i:1526310306;d:15.680899999999999;i:1526310006;d:14.158799999999999;i:1526309705;d:14.908300000000001;i:1526309405;d:16.721399999999999;i:1526309106;d:16.821899999999999;i:1526308805;d:24.448799999999999;i:1526308505;d:14.107900000000001;i:1526308205;d:14.505100000000001;i:1526307905;d:16.6511;i:1526307605;d:14.505699999999999;i:1526307305;d:20.250800000000002;i:1526307005;d:19.255800000000001;i:1526306706;d:12.5671;i:1526306420;d:11.337400000000001;}s:17:\"discovery_history\";a:6:{i:1526377094;d:13.9382;i:1526375869;d:15.0863;i:1526366050;d:13.773300000000001;i:1526344449;d:12.9566;i:1526322886;d:10.7845;i:1526306401;d:17.998899999999999;}}' WHERE `device_id` = '52'] ROWS[1] SQL RUNTIME[0.00531507s] ##### printer01.hq.leaf.space [52] completed discovery modules at 2018-05-15 09:38:28 #####   o Discovery time  13.9382 seconds  > $device_discovery_cache_keys /opt/observium/includes/discovery/functions.inc.php:422  array( [5] => string(12) "discovery_os" [6] => string(7) "devices" [7] => string(7) "attribs" [8] => string(10) "port_index" [9] => string(4) "port" ) SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '21103' AND `process_name` = 'discovery.php' AND `device_id` = '52'] ROWS[1] SQL RUNTIME[0.00435591s] SQL[SELECT * FROM `groups` ORDER BY `entity_type`] ROWS[4] SQL RUNTIME[0.00091195s] SQL[SELECT * FROM `groups_assoc`] ROWS[2] SQL RUNTIME[0.00084090s] SQL[SELECT device_id FROM `devices` WHERE( IFNULL(`devices`.`hostname`, "") LIKE '%leaf.space')] ROWS[23] SQL RUNTIME[0.00084209s] SQL[SELECT * FROM `group_table` WHERE `group_id` = '1'] ROWS[23] SQL RUNTIME[0.00073099s] SQL[SELECT device_id FROM `devices` WHERE( IFNULL(`devices`.`hostname`, "") LIKE '%italia1.gs.leaf.space')] ROWS[6] SQL RUNTIME[0.00097489s] SQL[SELECT * FROM `group_table` WHERE `group_id` = '2'] ROWS[6] SQL RUNTIME[0.00092196s] SQL[SELECT device_id FROM `devices` WHERE( IFNULL(`devices`.`hostname`, "") LIKE '%lituania1.gs.leaf.space')] ROWS[5] SQL RUNTIME[0.00101089s] SQL[SELECT * FROM `group_table` WHERE `group_id` = '3'] ROWS[5] SQL RUNTIME[0.00080299s] SQL[SELECT device_id FROM `devices` WHERE( IFNULL(`devices`.`hostname`, "") LIKE '%.hq.leaf.space')] ROWS[8] SQL RUNTIME[0.00085092s] SQL[SELECT * FROM `group_table` WHERE `group_id` = '4'] ROWS[8] SQL RUNTIME[0.00078702s] SQL[SELECT * FROM `alert_tests`] ROWS[1] SQL RUNTIME[0.00078893s] SQL[SELECT * FROM `alert_assoc`] ROWS[1] SQL RUNTIME[0.00096512s] SQL[SELECT COUNT(*) FROM `devices` AS d WHERE d.`device_id` = '52' AND IFNULL(d.`hostname`, "") LIKE '%leaf%'] ROWS[1] SQL RUNTIME[0.00096107s] SQL[SELECT * FROM `alert_table` WHERE `device_id` = '52'] ROWS[1] SQL RUNTIME[0.00756097s] SQL[SELECT * FROM `devices` WHERE `devices`.device_id = '52'] ROWS[1] SQL RUNTIME[0.00139093s] SQL[SELECT * FROM `devices` WHERE `devices`.`device_id` = '52'] ROWS[1] SQL RUNTIME[0.00099301s] ##### Finished discovery run at 2018-05-15 09:38:28 #####  ./discovery.php: printer01.hq.leaf.space - 1 devices discovered in 14.12 secs SQL[SELECT * FROM `observium_processes` WHERE `process_start` < '1526362694'] ROWS[0] SQL RUNTIME[0.00071406s] NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.  o Devices Discovered  1  o Discovery Time  14.12 secs  o Memory usage  14MB (peak: 14MB)  o MySQL Usage  Cell[34/0.029s] Row[34/0.048s] Rows[81/0.087s] Column[0/0s] Update[5/0.009s] Insert[2/0.01s] Delete[2/0.006s]  o RRDTool Usage