[observium@observium observium]$ ./discovery.php -d -m sensors -h boi-colo-pe-3
DEBUG!

CMD[/usr/bin/svn info /opt/observium]

CMD EXITCODE[0]
CMD RUNTIME[0.016s]
STDOUT[
Path: .
Working Copy Root Path: /opt/observium
URL: http://svn.observium.org/svn/observium/branches/stable
Repository Root: http://svn.observium.org/svn
Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8
Revision: 8850
Node Kind: directory
Schedule: normal
Last Changed Author: adama
Last Changed Rev: 8841
Last Changed Date: 2017-09-12 08:30:58 -0600 (Tue, 12 Sep 2017)

]

SQL RUNTIME[0.00009799s]

CMD[/usr/bin/snmpget --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0041s]
STDOUT[
NET-SNMP version: 5.7.2
]

CMD[/usr/bin/rrdtool --version | head -n1]

CMD EXITCODE[0]
CMD RUNTIME[0.0048s]
STDOUT[
RRDtool 1.6.0  Copyright by Tobias Oetiker <tobi@oetiker.ch>
]

CMD[/usr/bin/env apache2 -v | awk '/Server version:/ {print $3}']

CMD EXITCODE[0]
CMD RUNTIME[0.0054s]
STDOUT[

]

CMD[/usr/sbin/httpd -v | awk '/Server version:/ {print $3}']

CMD EXITCODE[0]
CMD RUNTIME[0.0247s]
STDOUT[
Apache/2.4.6
]

CMD[date "+%:z"]

CMD EXITCODE[0]
CMD RUNTIME[0.0013s]
STDOUT[
-06:00
]

SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);]
SQL RUNTIME[0.00028706s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00016093s]

SQL[SHOW VARIABLES LIKE 'character_set_connection']
SQL RUNTIME[0.00039482s]

#####  Software versions  #####

 o OS                   Linux 3.10.0-514.16.1.el7.x86_64 [amd64] (CentOS 7)
 o Apache               2.4.6
 o PHP                  7.0.18 (OPcache: ENABLED)
 o Python               2.7.5
 o MySQL                5.5.52-MariaDB (extension: mysqli 5.5.52-MariaDB)
 o SNMP                 NET-SNMP 5.7.2
 o RRDtool              1.6.0

#####  Memory Limit  #####

 o PHP                  512B

#####  MySQL mode  #####

 o MySQL                

#####  Charset info  #####

 o PHP                  UTF-8
 o MySQL                utf8

#####  Timezones info  #####

 o Date                 Monday, 30-Oct-17 14:59:06 MDT
 o PHP                  -06:00
 o MySQL                -06:00


SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';]
SQL RUNTIME[0.00036597s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';]
SQL RUNTIME[0.00008702s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver';]
SQL RUNTIME[0.00008798s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date';]
SQL RUNTIME[0.00008702s]
There is a newer revision of Observium available!
Version 17.10.8930 (30th October 2017) is 89 revisions ahead.

#####  Starting discovery run at 2017-10-30 14:59:06  #####


SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'boi-colo-pe-3' AND `status` = '1' ORDER BY `last_discovered_timetaken` ASC]
SQL RUNTIME[0.00034595s]

CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUst -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'boi-colo-pe-3':'161' sysObjectID.0 sysUpTime.0]

CMD EXITCODE[0]
CMD RUNTIME[0.015s]
STDOUT[
sysObjectID.0 = enterprises.9.1.2102
sysUpTime.0 = 3063161135
]
SNMP STATUS[TRUE]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '41']
SQL RUNTIME[0.00018311s]

SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '41']
SQL RUNTIME[0.00011992s]

CMD[/bin/ps -ww -o pid,ppid,uid,gid,tty,stat,time,lstart,args -p 9359]

CMD EXITCODE[0]
CMD RUNTIME[0.0122s]
CMD EXITDELAY[10ms]
STDOUT[
  PID  PPID   UID   GID TT       STAT     TIME                  STARTED COMMAND
 9359 60451  1001  1001 pts/1    S+   00:00:00 Mon Oct 30 14:59:06 2017 php ./discovery.php -d -m sensors -h boi-colo-pe-3
]

entSensorValueUpdateRate.379 = 60
entSensorValueUpdateRate.380 = 60
entSensorValueUpdateRate.381 = 60
entSensorValueUpdateRate.531 = 60
entSensorValueUpdateRate.532 = 60
entSensorValueUpdateRate.533 = 60
entSensorValueUpdateRate.534 = 60
entSensorValueUpdateRate.535 = 60
entSensorValueUpdateRate.699 = 60
entSensorValueUpdateRate.700 = 60
entSensorValueUpdateRate.701 = 60
entSensorValueUpdateRate.702 = 60
entSensorValueUpdateRate.703 = 60
entSensorValueUpdateRate.713 = 60
entSensorValueUpdateRate.714 = 60
entSensorValueUpdateRate.715 = 60
entSensorValueUpdateRate.716 = 60
entSensorValueUpdateRate.717 = 60
entSensorValueUpdateRate.727 = 60
entSensorValueUpdateRate.728 = 60
entSensorValueUpdateRate.729 = 60
entSensorValueUpdateRate.730 = 60
entSensorValueUpdateRate.731 = 60
entSensorValueUpdateRate.741 = 60
entSensorValueUpdateRate.742 = 60
entSensorValueUpdateRate.743 = 60
entSensorValueUpdateRate.744 = 60
entSensorValueUpdateRate.745 = 60
entSensorMeasuredEntity.7 = 6
entSensorMeasuredEntity.8 = 6
entSensorMeasuredEntity.9 = 6
entSensorMeasuredEntity.10 = 6
entSensorMeasuredEntity.11 = 6
entSensorMeasuredEntity.12 = 6
entSensorMeasuredEntity.27 = 26
entSensorMeasuredEntity.28 = 26
entSensorMeasuredEntity.29 = 26
entSensorMeasuredEntity.30 = 26
entSensorMeasuredEntity.31 = 26
entSensorMeasuredEntity.32 = 26
entSensorMeasuredEntity.47 = 46
entSensorMeasuredEntity.101 = 100
entSensorMeasuredEntity.102 = 100
entSensorMeasuredEntity.103 = 100
entSensorMeasuredEntity.104 = 100
entSensorMeasuredEntity.105 = 100
entSensorMeasuredEntity.106 = 100
entSensorMeasuredEntity.107 = 100
entSensorMeasuredEntity.108 = 100
entSensorMeasuredEntity.109 = 100
entSensorMeasuredEntity.110 = 100
entSensorMeasuredEntity.111 = 100
entSensorMeasuredEntity.112 = 100
entSensorMeasuredEntity.113 = 100
entSensorMeasuredEntity.114 = 100
entSensorMeasuredEntity.115 = 100
entSensorMeasuredEntity.116 = 100
entSensorMeasuredEntity.117 = 100
entSensorMeasuredEntity.118 = 100
entSensorMeasuredEntity.119 = 100
entSensorMeasuredEntity.120 = 100
entSensorMeasuredEntity.121 = 100
entSensorMeasuredEntity.122 = 100
entSensorMeasuredEntity.377 = 0
entSensorMeasuredEntity.378 = 0
entSensorMeasuredEntity.379 = 0
entSensorMeasuredEntity.380 = 0
entSensorMeasuredEntity.381 = 0
entSensorMeasuredEntity.531 = 0
entSensorMeasuredEntity.532 = 0
entSensorMeasuredEntity.533 = 0
entSensorMeasuredEntity.534 = 0
entSensorMeasuredEntity.535 = 0
entSensorMeasuredEntity.699 = 0
entSensorMeasuredEntity.700 = 0
entSensorMeasuredEntity.701 = 0
entSensorMeasuredEntity.702 = 0
entSensorMeasuredEntity.703 = 0
entSensorMeasuredEntity.713 = 0
entSensorMeasuredEntity.714 = 0
entSensorMeasuredEntity.715 = 0
entSensorMeasuredEntity.716 = 0
entSensorMeasuredEntity.717 = 0
entSensorMeasuredEntity.727 = 0
entSensorMeasuredEntity.728 = 0
entSensorMeasuredEntity.729 = 0
entSensorMeasuredEntity.730 = 0
entSensorMeasuredEntity.731 = 0
entSensorMeasuredEntity.741 = 0
entSensorMeasuredEntity.742 = 0
entSensorMeasuredEntity.743 = 0
entSensorMeasuredEntity.744 = 0
entSensorMeasuredEntity.745 = 0
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.0706s]
STDOUT[
entPhysicalDescr.1 = Cisco ASR920 Series - 24GE Fiber and 4-10GE - Modular PSU
entPhysicalDescr.2 = FIXED RSP Slot
entPhysicalDescr.3 = FIXED IM Bay
entPhysicalDescr.4 = FIXED IM Bay
entPhysicalDescr.5 = Power Supply Bay
entPhysicalDescr.6 = ASR 920 250W DC Power Supply
entPhysicalDescr.7 = PEM Iout
entPhysicalDescr.8 = PEM Vout
entPhysicalDescr.9 = PEM Vin
entPhysicalDescr.10 = PEM Pin
entPhysicalDescr.11 = Temp: Temp 3  
entPhysicalDescr.12 = Temp: Temp 2  
entPhysicalDescr.25 = Power Supply Bay
entPhysicalDescr.26 = ASR 920 250W DC Power Supply
entPhysicalDescr.27 = PEM Iout
entPhysicalDescr.28 = PEM Vout
entPhysicalDescr.29 = PEM Vin
entPhysicalDescr.30 = PEM Pin
entPhysicalDescr.31 = Temp: Temp 3  
entPhysicalDescr.32 = Temp: Temp 2  
entPhysicalDescr.45 = Fan Tray Bay
entPhysicalDescr.46 = ASR 920 Fan tray
entPhysicalDescr.47 = Temp: FC PWM 
entPhysicalDescr.108 = VADM1: VH
entPhysicalDescr.109 = VADM1: AUX1
entPhysicalDescr.110 = VADM1: AUX2
entPhysicalDescr.111 = Temp: CYLON   
entPhysicalDescr.112 = Temp: BOARD   
entPhysicalDescr.113 = Temp: Outlet  
entPhysicalDescr.114 = Temp: CPU     
entPhysicalDescr.115 = VADM2: VX1
entPhysicalDescr.116 = VADM2: VX2
entPhysicalDescr.117 = VADM2: VX3
entPhysicalDescr.118 = VADM2: VP1
entPhysicalDescr.119 = VADM2: VP2
entPhysicalDescr.120 = VADM2: VP3
entPhysicalDescr.121 = VADM2: VH
entPhysicalDescr.122 = Temp: Inlet   
entPhysicalDescr.130 = CYLON   
entPhysicalDescr.131 = CPU 0 of module R0
entPhysicalDescr.132 = USB Port
entPhysicalDescr.134 = USB Port
entPhysicalDescr.136 = Network Management Ethernet
entPhysicalDescr.300 = FIXED : 24-port Gig & 4-port Ten Gig SFP Ethernet Interface Module
entPhysicalDescr.359 = subslot 0/0 transceiver container 0
entPhysicalDescr.373 = subslot 0/0 transceiver container 1
entPhysicalDescr.374 = GE LX
entPhysicalDescr.375 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.377 = subslot 0/0 transceiver 1 Temperature Sensor
entPhysicalDescr.378 = subslot 0/0 transceiver 1 Supply Voltage Sensor
entPhysicalDescr.379 = subslot 0/0 transceiver 1 Bias Current Sensor
entPhysicalDescr.380 = subslot 0/0 transceiver 1 Tx Power Sensor
entPhysicalDescr.381 = subslot 0/0 transceiver 1 Rx Power Sensor
entPhysicalDescr.387 = subslot 0/0 transceiver container 2
entPhysicalDescr.401 = subslot 0/0 transceiver container 3
entPhysicalDescr.415 = subslot 0/0 transceiver container 4
entPhysicalDescr.429 = subslot 0/0 transceiver container 5
entPhysicalDescr.443 = subslot 0/0 transceiver container 6
entPhysicalDescr.457 = subslot 0/0 transceiver container 7
entPhysicalDescr.471 = subslot 0/0 transceiver container 8
entPhysicalDescr.485 = subslot 0/0 transceiver container 9
entPhysicalDescr.499 = subslot 0/0 transceiver container 10
entPhysicalDescr.513 = subslot 0/0 transceiver container 11
entPhysicalDescr.527 = subslot 0/0 transceiver container 12
entPhysicalDescr.528 = GE LX
entPhysicalDescr.529 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.531 = subslot 0/0 transceiver 12 Temperature Sensor
entPhysicalDescr.532 = subslot 0/0 transceiver 12 Supply Voltage Sensor
entPhysicalDescr.533 = subslot 0/0 transceiver 12 Bias Current Sensor
entPhysicalDescr.534 = subslot 0/0 transceiver 12 Tx Power Sensor
entPhysicalDescr.535 = subslot 0/0 transceiver 12 Rx Power Sensor
entPhysicalDescr.541 = subslot 0/0 transceiver container 13
entPhysicalDescr.555 = subslot 0/0 transceiver container 14
entPhysicalDescr.569 = subslot 0/0 transceiver container 15
entPhysicalDescr.583 = subslot 0/0 transceiver container 16
entPhysicalDescr.597 = subslot 0/0 transceiver container 17
entPhysicalDescr.611 = subslot 0/0 transceiver container 18
entPhysicalDescr.625 = subslot 0/0 transceiver container 19
entPhysicalDescr.639 = subslot 0/0 transceiver container 20
entPhysicalDescr.653 = subslot 0/0 transceiver container 21
entPhysicalDescr.667 = subslot 0/0 transceiver container 22
entPhysicalDescr.668 = GE T
entPhysicalDescr.669 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.681 = subslot 0/0 transceiver container 23
entPhysicalDescr.695 = subslot 0/0 transceiver container 24
entPhysicalDescr.696 = SFP+ 10GBASE-LR
entPhysicalDescr.697 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.699 = subslot 0/0 transceiver 24 Temperature Sensor
entPhysicalDescr.700 = subslot 0/0 transceiver 24 Supply Voltage Sensor
entPhysicalDescr.701 = subslot 0/0 transceiver 24 Bias Current Sensor
entPhysicalDescr.702 = subslot 0/0 transceiver 24 Tx Power Sensor
entPhysicalDescr.703 = subslot 0/0 transceiver 24 Rx Power Sensor
entPhysicalDescr.709 = subslot 0/0 transceiver container 25
entPhysicalDescr.710 = SFP+ 10GBASE-LR
entPhysicalDescr.711 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.713 = subslot 0/0 transceiver 25 Temperature Sensor
entPhysicalDescr.714 = subslot 0/0 transceiver 25 Supply Voltage Sensor
entPhysicalDescr.715 = subslot 0/0 transceiver 25 Bias Current Sensor
entPhysicalDescr.716 = subslot 0/0 transceiver 25 Tx Power Sensor
entPhysicalDescr.717 = subslot 0/0 transceiver 25 Rx Power Sensor
entPhysicalDescr.723 = subslot 0/0 transceiver container 26
entPhysicalDescr.724 = SFP+ 10GBASE-ER
entPhysicalDescr.725 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.727 = subslot 0/0 transceiver 26 Temperature Sensor
entPhysicalDescr.728 = subslot 0/0 transceiver 26 Supply Voltage Sensor
entPhysicalDescr.729 = subslot 0/0 transceiver 26 Bias Current Sensor
entPhysicalDescr.730 = subslot 0/0 transceiver 26 Tx Power Sensor
entPhysicalDescr.731 = subslot 0/0 transceiver 26 Rx Power Sensor
entPhysicalDescr.737 = subslot 0/0 transceiver container 27
entPhysicalDescr.738 = SFP+ 10GBASE-LR
entPhysicalDescr.739 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.741 = subslot 0/0 transceiver 27 Temperature Sensor
entPhysicalDescr.742 = subslot 0/0 transceiver 27 Supply Voltage Sensor
entPhysicalDescr.743 = subslot 0/0 transceiver 27 Bias Current Sensor
entPhysicalDescr.744 = subslot 0/0 transceiver 27 Tx Power Sensor
entPhysicalDescr.745 = subslot 0/0 transceiver 27 Rx Power Sensor
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalName]

CMD EXITCODE[0]
CMD RUNTIME[0.0707s]
STDOUT[
entPhysicalName.1 = Chassis
entPhysicalName.2 = slot R0
entPhysicalName.3 = subslot 0/0
entPhysicalName.4 = subslot 0/1
entPhysicalName.5 = Power Supply Bay 0
entPhysicalName.6 = Power Supply Module 0
entPhysicalName.7 = PEM Iout P0/0
entPhysicalName.8 = PEM Vout P0/1
entPhysicalName.9 = PEM Vin P0/2
entPhysicalName.10 = PEM Pin P0/3
entPhysicalName.11 = Temp: Temp 3   P0/4
entPhysicalName.12 = Temp: Temp 2   P0/5
entPhysicalName.25 = Power Supply Bay 1
entPhysicalName.26 = Power Supply Module 1
entPhysicalName.27 = PEM Iout P1/0
entPhysicalName.28 = PEM Vout P1/1
entPhysicalName.29 = PEM Vin P1/2
entPhysicalName.30 = PEM Pin P1/3
entPhysicalName.31 = Temp: Temp 3   P1/4
entPhysicalName.32 = Temp: Temp 2   P1/5
entPhysicalName.45 = Fan Tray Bay 0
entPhysicalName.46 = Fan Tray
entPhysicalName.47 = Temp: FC PWM  P2/0
entPhysicalName.108 = VADM1: VH R0/7
entPhysicalName.109 = VADM1: AUX1 R0/8
entPhysicalName.110 = VADM1: AUX2 R0/9
entPhysicalName.111 = Temp: CYLON    R0/10
entPhysicalName.112 = Temp: BOARD    R0/11
entPhysicalName.113 = Temp: Outlet   R0/12
entPhysicalName.114 = Temp: CPU      R0/13
entPhysicalName.115 = VADM2: VX1 R0/14
entPhysicalName.116 = VADM2: VX2 R0/15
entPhysicalName.117 = VADM2: VX3 R0/16
entPhysicalName.118 = VADM2: VP1 R0/17
entPhysicalName.119 = VADM2: VP2 R0/18
entPhysicalName.120 = VADM2: VP3 R0/19
entPhysicalName.121 = VADM2: VH R0/20
entPhysicalName.122 = Temp: Inlet    R0/21
entPhysicalName.130 = CYLON   
entPhysicalName.131 = cpu R0/0
entPhysicalName.132 = usb R0/0
entPhysicalName.134 = usb R0/1
entPhysicalName.136 = NME R0
entPhysicalName.300 =  FIXED IM subslot 0/0
entPhysicalName.359 = subslot 0/0 transceiver container 0
entPhysicalName.373 = subslot 0/0 transceiver container 1
entPhysicalName.374 = subslot 0/0 transceiver 1
entPhysicalName.375 = GigabitEthernet0/0/1
entPhysicalName.377 = subslot 0/0 transceiver 1 Temperature Sensor
entPhysicalName.378 = subslot 0/0 transceiver 1 Supply Voltage Sensor
entPhysicalName.379 = subslot 0/0 transceiver 1 Bias Current Sensor
entPhysicalName.380 = subslot 0/0 transceiver 1 Tx Power Sensor
entPhysicalName.381 = subslot 0/0 transceiver 1 Rx Power Sensor
entPhysicalName.387 = subslot 0/0 transceiver container 2
entPhysicalName.401 = subslot 0/0 transceiver container 3
entPhysicalName.415 = subslot 0/0 transceiver container 4
entPhysicalName.429 = subslot 0/0 transceiver container 5
entPhysicalName.443 = subslot 0/0 transceiver container 6
entPhysicalName.457 = subslot 0/0 transceiver container 7
entPhysicalName.471 = subslot 0/0 transceiver container 8
entPhysicalName.485 = subslot 0/0 transceiver container 9
entPhysicalName.499 = subslot 0/0 transceiver container 10
entPhysicalName.513 = subslot 0/0 transceiver container 11
entPhysicalName.527 = subslot 0/0 transceiver container 12
entPhysicalName.528 = subslot 0/0 transceiver 12
entPhysicalName.529 = GigabitEthernet0/0/12
entPhysicalName.531 = subslot 0/0 transceiver 12 Temperature Sensor
entPhysicalName.532 = subslot 0/0 transceiver 12 Supply Voltage Sensor
entPhysicalName.533 = subslot 0/0 transceiver 12 Bias Current Sensor
entPhysicalName.534 = subslot 0/0 transceiver 12 Tx Power Sensor
entPhysicalName.535 = subslot 0/0 transceiver 12 Rx Power Sensor
entPhysicalName.541 = subslot 0/0 transceiver container 13
entPhysicalName.555 = subslot 0/0 transceiver container 14
entPhysicalName.569 = subslot 0/0 transceiver container 15
entPhysicalName.583 = subslot 0/0 transceiver container 16
entPhysicalName.597 = subslot 0/0 transceiver container 17
entPhysicalName.611 = subslot 0/0 transceiver container 18
entPhysicalName.625 = subslot 0/0 transceiver container 19
entPhysicalName.639 = subslot 0/0 transceiver container 20
entPhysicalName.653 = subslot 0/0 transceiver container 21
entPhysicalName.667 = subslot 0/0 transceiver container 22
entPhysicalName.668 = subslot 0/0 transceiver 22
entPhysicalName.669 = GigabitEthernet0/0/22
entPhysicalName.681 = subslot 0/0 transceiver container 23
entPhysicalName.695 = subslot 0/0 transceiver container 24
entPhysicalName.696 = subslot 0/0 transceiver 24
entPhysicalName.697 = TenGigabitEthernet0/0/24
entPhysicalName.699 = subslot 0/0 transceiver 24 Temperature Sensor
entPhysicalName.700 = subslot 0/0 transceiver 24 Supply Voltage Sensor
entPhysicalName.701 = subslot 0/0 transceiver 24 Bias Current Sensor
entPhysicalName.702 = subslot 0/0 transceiver 24 Tx Power Sensor
entPhysicalName.703 = subslot 0/0 transceiver 24 Rx Power Sensor
entPhysicalName.709 = subslot 0/0 transceiver container 25
entPhysicalName.710 = subslot 0/0 transceiver 25
entPhysicalName.711 = TenGigabitEthernet0/0/25
entPhysicalName.713 = subslot 0/0 transceiver 25 Temperature Sensor
entPhysicalName.714 = subslot 0/0 transceiver 25 Supply Voltage Sensor
entPhysicalName.715 = subslot 0/0 transceiver 25 Bias Current Sensor
entPhysicalName.716 = subslot 0/0 transceiver 25 Tx Power Sensor
entPhysicalName.717 = subslot 0/0 transceiver 25 Rx Power Sensor
entPhysicalName.723 = subslot 0/0 transceiver container 26
entPhysicalName.724 = subslot 0/0 transceiver 26
entPhysicalName.725 = TenGigabitEthernet0/0/26
entPhysicalName.727 = subslot 0/0 transceiver 26 Temperature Sensor
entPhysicalName.728 = subslot 0/0 transceiver 26 Supply Voltage Sensor
entPhysicalName.729 = subslot 0/0 transceiver 26 Bias Current Sensor
entPhysicalName.730 = subslot 0/0 transceiver 26 Tx Power Sensor
entPhysicalName.731 = subslot 0/0 transceiver 26 Rx Power Sensor
entPhysicalName.737 = subslot 0/0 transceiver container 27
entPhysicalName.738 = subslot 0/0 transceiver 27
entPhysicalName.739 = TenGigabitEthernet0/0/27
entPhysicalName.741 = subslot 0/0 transceiver 27 Temperature Sensor
entPhysicalName.742 = subslot 0/0 transceiver 27 Supply Voltage Sensor
entPhysicalName.743 = subslot 0/0 transceiver 27 Bias Current Sensor
entPhysicalName.744 = subslot 0/0 transceiver 27 Tx Power Sensor
entPhysicalName.745 = subslot 0/0 transceiver 27 Rx Power Sensor
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalClass]

CMD EXITCODE[0]
CMD RUNTIME[0.0761s]
STDOUT[
entPhysicalClass.1 = chassis
entPhysicalClass.2 = container
entPhysicalClass.3 = container
entPhysicalClass.4 = container
entPhysicalClass.5 = container
entPhysicalClass.6 = powerSupply
entPhysicalClass.7 = sensor
entPhysicalClass.8 = sensor
entPhysicalClass.9 = sensor
entPhysicalClass.10 = sensor
entPhysicalClass.11 = sensor
entPhysicalClass.12 = sensor
entPhysicalClass.25 = container
entPhysicalClass.26 = powerSupply
entPhysicalClass.27 = sensor
entPhysicalClass.28 = sensor
entPhysicalClass.29 = sensor
entPhysicalClass.30 = sensor
entPhysicalClass.31 = sensor
entPhysicalClass.32 = sensor
entPhysicalClass.45 = container
entPhysicalClass.46 = fan
entPhysicalClass.47 = sensor
entPhysicalClass.108 = sensor
entPhysicalClass.109 = sensor
entPhysicalClass.110 = sensor
entPhysicalClass.111 = sensor
entPhysicalClass.112 = sensor
entPhysicalClass.113 = sensor
entPhysicalClass.114 = sensor
entPhysicalClass.115 = sensor
entPhysicalClass.116 = sensor
entPhysicalClass.117 = sensor
entPhysicalClass.118 = sensor
entPhysicalClass.119 = sensor
entPhysicalClass.120 = sensor
entPhysicalClass.121 = sensor
entPhysicalClass.122 = sensor
entPhysicalClass.130 = cpu
entPhysicalClass.131 = cpu
entPhysicalClass.132 = container
entPhysicalClass.134 = container
entPhysicalClass.136 = port
entPhysicalClass.300 = module
entPhysicalClass.359 = container
entPhysicalClass.373 = container
entPhysicalClass.374 = module
entPhysicalClass.375 = port
entPhysicalClass.377 = sensor
entPhysicalClass.378 = sensor
entPhysicalClass.379 = sensor
entPhysicalClass.380 = sensor
entPhysicalClass.381 = sensor
entPhysicalClass.387 = container
entPhysicalClass.401 = container
entPhysicalClass.415 = container
entPhysicalClass.429 = container
entPhysicalClass.443 = container
entPhysicalClass.457 = container
entPhysicalClass.471 = container
entPhysicalClass.485 = container
entPhysicalClass.499 = container
entPhysicalClass.513 = container
entPhysicalClass.527 = container
entPhysicalClass.528 = module
entPhysicalClass.529 = port
entPhysicalClass.531 = sensor
entPhysicalClass.532 = sensor
entPhysicalClass.533 = sensor
entPhysicalClass.534 = sensor
entPhysicalClass.535 = sensor
entPhysicalClass.541 = container
entPhysicalClass.555 = container
entPhysicalClass.569 = container
entPhysicalClass.583 = container
entPhysicalClass.597 = container
entPhysicalClass.611 = container
entPhysicalClass.625 = container
entPhysicalClass.639 = container
entPhysicalClass.653 = container
entPhysicalClass.667 = container
entPhysicalClass.668 = module
entPhysicalClass.669 = port
entPhysicalClass.681 = container
entPhysicalClass.695 = container
entPhysicalClass.696 = module
entPhysicalClass.697 = port
entPhysicalClass.699 = sensor
entPhysicalClass.700 = sensor
entPhysicalClass.701 = sensor
entPhysicalClass.702 = sensor
entPhysicalClass.703 = sensor
entPhysicalClass.709 = container
entPhysicalClass.710 = module
entPhysicalClass.711 = port
entPhysicalClass.713 = sensor
entPhysicalClass.714 = sensor
entPhysicalClass.715 = sensor
entPhysicalClass.716 = sensor
entPhysicalClass.717 = sensor
entPhysicalClass.723 = container
entPhysicalClass.724 = module
entPhysicalClass.725 = port
entPhysicalClass.727 = sensor
entPhysicalClass.728 = sensor
entPhysicalClass.729 = sensor
entPhysicalClass.730 = sensor
entPhysicalClass.731 = sensor
entPhysicalClass.737 = container
entPhysicalClass.738 = module
entPhysicalClass.739 = port
entPhysicalClass.741 = sensor
entPhysicalClass.742 = sensor
entPhysicalClass.743 = sensor
entPhysicalClass.744 = sensor
entPhysicalClass.745 = sensor
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalContainedIn]

CMD EXITCODE[0]
CMD RUNTIME[0.083s]
STDOUT[
entPhysicalContainedIn.1 = 0
entPhysicalContainedIn.2 = 1
entPhysicalContainedIn.3 = 1
entPhysicalContainedIn.4 = 1
entPhysicalContainedIn.5 = 1
entPhysicalContainedIn.6 = 5
entPhysicalContainedIn.7 = 6
entPhysicalContainedIn.8 = 6
entPhysicalContainedIn.9 = 6
entPhysicalContainedIn.10 = 6
entPhysicalContainedIn.11 = 6
entPhysicalContainedIn.12 = 6
entPhysicalContainedIn.25 = 1
entPhysicalContainedIn.26 = 25
entPhysicalContainedIn.27 = 26
entPhysicalContainedIn.28 = 26
entPhysicalContainedIn.29 = 26
entPhysicalContainedIn.30 = 26
entPhysicalContainedIn.31 = 26
entPhysicalContainedIn.32 = 26
entPhysicalContainedIn.45 = 1
entPhysicalContainedIn.46 = 45
entPhysicalContainedIn.47 = 46
entPhysicalContainedIn.108 = 100
entPhysicalContainedIn.109 = 100
entPhysicalContainedIn.110 = 100
entPhysicalContainedIn.111 = 100
entPhysicalContainedIn.112 = 100
entPhysicalContainedIn.113 = 100
entPhysicalContainedIn.114 = 100
entPhysicalContainedIn.115 = 100
entPhysicalContainedIn.116 = 100
entPhysicalContainedIn.117 = 100
entPhysicalContainedIn.118 = 100
entPhysicalContainedIn.119 = 100
entPhysicalContainedIn.120 = 100
entPhysicalContainedIn.121 = 100
entPhysicalContainedIn.122 = 100
entPhysicalContainedIn.130 = 100
entPhysicalContainedIn.131 = 100
entPhysicalContainedIn.132 = 100
entPhysicalContainedIn.134 = 100
entPhysicalContainedIn.136 = 100
entPhysicalContainedIn.300 = 3
entPhysicalContainedIn.359 = 300
entPhysicalContainedIn.373 = 300
entPhysicalContainedIn.374 = 373
entPhysicalContainedIn.375 = 374
entPhysicalContainedIn.377 = 374
entPhysicalContainedIn.378 = 374
entPhysicalContainedIn.379 = 374
entPhysicalContainedIn.380 = 374
entPhysicalContainedIn.381 = 374
entPhysicalContainedIn.387 = 300
entPhysicalContainedIn.401 = 300
entPhysicalContainedIn.415 = 300
entPhysicalContainedIn.429 = 300
entPhysicalContainedIn.443 = 300
entPhysicalContainedIn.457 = 300
entPhysicalContainedIn.471 = 300
entPhysicalContainedIn.485 = 300
entPhysicalContainedIn.499 = 300
entPhysicalContainedIn.513 = 300
entPhysicalContainedIn.527 = 300
entPhysicalContainedIn.528 = 527
entPhysicalContainedIn.529 = 528
entPhysicalContainedIn.531 = 528
entPhysicalContainedIn.532 = 528
entPhysicalContainedIn.533 = 528
entPhysicalContainedIn.534 = 528
entPhysicalContainedIn.535 = 528
entPhysicalContainedIn.541 = 300
entPhysicalContainedIn.555 = 300
entPhysicalContainedIn.569 = 300
entPhysicalContainedIn.583 = 300
entPhysicalContainedIn.597 = 300
entPhysicalContainedIn.611 = 300
entPhysicalContainedIn.625 = 300
entPhysicalContainedIn.639 = 300
entPhysicalContainedIn.653 = 300
entPhysicalContainedIn.667 = 300
entPhysicalContainedIn.668 = 667
entPhysicalContainedIn.669 = 668
entPhysicalContainedIn.681 = 300
entPhysicalContainedIn.695 = 300
entPhysicalContainedIn.696 = 695
entPhysicalContainedIn.697 = 696
entPhysicalContainedIn.699 = 696
entPhysicalContainedIn.700 = 696
entPhysicalContainedIn.701 = 696
entPhysicalContainedIn.702 = 696
entPhysicalContainedIn.703 = 696
entPhysicalContainedIn.709 = 300
entPhysicalContainedIn.710 = 709
entPhysicalContainedIn.711 = 710
entPhysicalContainedIn.713 = 710
entPhysicalContainedIn.714 = 710
entPhysicalContainedIn.715 = 710
entPhysicalContainedIn.716 = 710
entPhysicalContainedIn.717 = 710
entPhysicalContainedIn.723 = 300
entPhysicalContainedIn.724 = 723
entPhysicalContainedIn.725 = 724
entPhysicalContainedIn.727 = 724
entPhysicalContainedIn.728 = 724
entPhysicalContainedIn.729 = 724
entPhysicalContainedIn.730 = 724
entPhysicalContainedIn.731 = 724
entPhysicalContainedIn.737 = 300
entPhysicalContainedIn.738 = 737
entPhysicalContainedIn.739 = 738
entPhysicalContainedIn.741 = 738
entPhysicalContainedIn.742 = 738
entPhysicalContainedIn.743 = 738
entPhysicalContainedIn.744 = 738
entPhysicalContainedIn.745 = 738
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalParentRelPos]

CMD EXITCODE[0]
CMD RUNTIME[0.0815s]
STDOUT[
entPhysicalParentRelPos.1 = -1
entPhysicalParentRelPos.2 = 6
entPhysicalParentRelPos.3 = 0
entPhysicalParentRelPos.4 = 1
entPhysicalParentRelPos.5 = 11
entPhysicalParentRelPos.6 = 0
entPhysicalParentRelPos.7 = 0
entPhysicalParentRelPos.8 = 1
entPhysicalParentRelPos.9 = 2
entPhysicalParentRelPos.10 = 3
entPhysicalParentRelPos.11 = 4
entPhysicalParentRelPos.12 = 5
entPhysicalParentRelPos.25 = 12
entPhysicalParentRelPos.26 = 0
entPhysicalParentRelPos.27 = 0
entPhysicalParentRelPos.28 = 1
entPhysicalParentRelPos.29 = 2
entPhysicalParentRelPos.30 = 3
entPhysicalParentRelPos.31 = 4
entPhysicalParentRelPos.32 = 5
entPhysicalParentRelPos.45 = 13
entPhysicalParentRelPos.46 = 0
entPhysicalParentRelPos.47 = 0
entPhysicalParentRelPos.108 = 7
entPhysicalParentRelPos.109 = 8
entPhysicalParentRelPos.110 = 9
entPhysicalParentRelPos.111 = 10
entPhysicalParentRelPos.112 = 11
entPhysicalParentRelPos.113 = 12
entPhysicalParentRelPos.114 = 13
entPhysicalParentRelPos.115 = 14
entPhysicalParentRelPos.116 = 15
entPhysicalParentRelPos.117 = 16
entPhysicalParentRelPos.118 = 17
entPhysicalParentRelPos.119 = 18
entPhysicalParentRelPos.120 = 19
entPhysicalParentRelPos.121 = 20
entPhysicalParentRelPos.122 = 21
entPhysicalParentRelPos.130 = 1
entPhysicalParentRelPos.131 = 0
entPhysicalParentRelPos.132 = 0
entPhysicalParentRelPos.134 = 1
entPhysicalParentRelPos.136 = 2
entPhysicalParentRelPos.300 = 0
entPhysicalParentRelPos.359 = 0
entPhysicalParentRelPos.373 = 1
entPhysicalParentRelPos.374 = 0
entPhysicalParentRelPos.375 = 0
entPhysicalParentRelPos.377 = 1
entPhysicalParentRelPos.378 = 2
entPhysicalParentRelPos.379 = 3
entPhysicalParentRelPos.380 = 4
entPhysicalParentRelPos.381 = 5
entPhysicalParentRelPos.387 = 2
entPhysicalParentRelPos.401 = 3
entPhysicalParentRelPos.415 = 4
entPhysicalParentRelPos.429 = 5
entPhysicalParentRelPos.443 = 6
entPhysicalParentRelPos.457 = 7
entPhysicalParentRelPos.471 = 8
entPhysicalParentRelPos.485 = 9
entPhysicalParentRelPos.499 = 10
entPhysicalParentRelPos.513 = 11
entPhysicalParentRelPos.527 = 12
entPhysicalParentRelPos.528 = 0
entPhysicalParentRelPos.529 = 0
entPhysicalParentRelPos.531 = 1
entPhysicalParentRelPos.532 = 2
entPhysicalParentRelPos.533 = 3
entPhysicalParentRelPos.534 = 4
entPhysicalParentRelPos.535 = 5
entPhysicalParentRelPos.541 = 13
entPhysicalParentRelPos.555 = 14
entPhysicalParentRelPos.569 = 15
entPhysicalParentRelPos.583 = 16
entPhysicalParentRelPos.597 = 17
entPhysicalParentRelPos.611 = 18
entPhysicalParentRelPos.625 = 19
entPhysicalParentRelPos.639 = 20
entPhysicalParentRelPos.653 = 21
entPhysicalParentRelPos.667 = 22
entPhysicalParentRelPos.668 = 0
entPhysicalParentRelPos.669 = 0
entPhysicalParentRelPos.681 = 23
entPhysicalParentRelPos.695 = 24
entPhysicalParentRelPos.696 = 0
entPhysicalParentRelPos.697 = 0
entPhysicalParentRelPos.699 = 1
entPhysicalParentRelPos.700 = 2
entPhysicalParentRelPos.701 = 3
entPhysicalParentRelPos.702 = 4
entPhysicalParentRelPos.703 = 5
entPhysicalParentRelPos.709 = 25
entPhysicalParentRelPos.710 = 0
entPhysicalParentRelPos.711 = 0
entPhysicalParentRelPos.713 = 1
entPhysicalParentRelPos.714 = 2
entPhysicalParentRelPos.715 = 3
entPhysicalParentRelPos.716 = 4
entPhysicalParentRelPos.717 = 5
entPhysicalParentRelPos.723 = 26
entPhysicalParentRelPos.724 = 0
entPhysicalParentRelPos.725 = 0
entPhysicalParentRelPos.727 = 1
entPhysicalParentRelPos.728 = 2
entPhysicalParentRelPos.729 = 3
entPhysicalParentRelPos.730 = 4
entPhysicalParentRelPos.731 = 5
entPhysicalParentRelPos.737 = 27
entPhysicalParentRelPos.738 = 0
entPhysicalParentRelPos.739 = 0
entPhysicalParentRelPos.741 = 1
entPhysicalParentRelPos.742 = 2
entPhysicalParentRelPos.743 = 3
entPhysicalParentRelPos.744 = 4
entPhysicalParentRelPos.745 = 5
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'boi-colo-pe-3':'161' entAliasMappingIdentifier]

CMD EXITCODE[0]
CMD RUNTIME[0.0106s]
STDOUT[
entAliasMappingIdentifier.136.0 = ifIndex.29
entAliasMappingIdentifier.375.0 = ifIndex.2
entAliasMappingIdentifier.529.0 = ifIndex.13
entAliasMappingIdentifier.669.0 = ifIndex.23
entAliasMappingIdentifier.697.0 = ifIndex.25
entAliasMappingIdentifier.711.0 = ifIndex.26
entAliasMappingIdentifier.725.0 = ifIndex.27
entAliasMappingIdentifier.739.0 = ifIndex.28
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entSensorThresholdSeverity]

CMD EXITCODE[0]
CMD RUNTIME[0.0522s]
STDOUT[
entSensorThresholdSeverity.11.1 = minor
entSensorThresholdSeverity.11.2 = major
entSensorThresholdSeverity.11.3 = critical
entSensorThresholdSeverity.11.4 = critical
entSensorThresholdSeverity.12.1 = minor
entSensorThresholdSeverity.12.2 = major
entSensorThresholdSeverity.12.3 = critical
entSensorThresholdSeverity.532.4 = critical
entSensorThresholdSeverity.533.1 = critical
entSensorThresholdSeverity.533.2 = minor
entSensorThresholdSeverity.533.3 = minor
entSensorThresholdSeverity.533.4 = critical
entSensorThresholdSeverity.534.1 = critical
entSensorThresholdSeverity.534.2 = minor
entSensorThresholdSeverity.534.3 = minor
entSensorThresholdSeverity.534.4 = critical
entSensorThresholdSeverity.535.1 = critical
entSensorThresholdSeverity.535.2 = minor
entSensorThresholdSeverity.535.3 = minor
entSensorThresholdSeverity.535.4 = critical
entSensorThresholdSeverity.699.1 = critical
entSensorThresholdSeverity.699.2 = minor
entSensorThresholdSeverity.699.3 = minor
entSensorThresholdSeverity.699.4 = critical
entSensorThresholdSeverity.700.1 = critical
entSensorThresholdSeverity.700.2 = minor
entSensorThresholdSeverity.700.3 = minor
entSensorThresholdSeverity.700.4 = critical
entSensorThresholdSeverity.701.1 = critical
entSensorThresholdSeverity.701.2 = minor
entSensorThresholdSeverity.701.3 = minor
entSensorThresholdSeverity.701.4 = critical
entSensorThresholdSeverity.702.1 = critical
entSensorThresholdSeverity.702.2 = minor
entSensorThresholdSeverity.702.3 = minor
entSensorThresholdSeverity.702.4 = critical
entSensorThresholdSeverity.703.1 = critical
entSensorThresholdSeverity.703.2 = minor
entSensorThresholdSeverity.703.3 = minor
entSensorThresholdSeverity.703.4 = critical
entSensorThresholdSeverity.713.1 = critical
entSensorThresholdSeverity.713.2 = minor
entSensorThresholdSeverity.713.3 = minor
entSensorThresholdSeverity.713.4 = critical
entSensorThresholdSeverity.714.1 = critical
entSensorThresholdSeverity.714.2 = minor
entSensorThresholdSeverity.714.3 = minor
entSensorThresholdSeverity.714.4 = critical
entSensorThresholdSeverity.715.1 = critical
entSensorThresholdSeverity.715.2 = minor
entSensorThresholdSeverity.715.3 = minor
entSensorThresholdSeverity.715.4 = critical
entSensorThresholdSeverity.716.1 = critical
entSensorThresholdSeverity.716.2 = minor
entSensorThresholdSeverity.716.3 = minor
entSensorThresholdSeverity.716.4 = critical
entSensorThresholdSeverity.717.1 = critical
entSensorThresholdSeverity.717.2 = minor
entSensorThresholdSeverity.717.3 = minor
entSensorThresholdSeverity.717.4 = critical
entSensorThresholdSeverity.727.1 = critical
entSensorThresholdSeverity.727.2 = minor
entSensorThresholdSeverity.727.3 = minor
entSensorThresholdSeverity.727.4 = critical
entSensorThresholdSeverity.728.1 = critical
entSensorThresholdSeverity.728.2 = minor
entSensorThresholdSeverity.728.3 = minor
entSensorThresholdSeverity.728.4 = critical
entSensorThresholdSeverity.729.1 = critical
entSensorThresholdSeverity.729.2 = minor
entSensorThresholdSeverity.729.3 = minor
entSensorThresholdSeverity.729.4 = critical
entSensorThresholdSeverity.730.1 = critical
entSensorThresholdSeverity.730.2 = minor
entSensorThresholdSeverity.730.3 = minor
entSensorThresholdSeverity.730.4 = critical
entSensorThresholdSeverity.731.1 = critical
entSensorThresholdSeverity.731.2 = minor
entSensorThresholdSeverity.731.3 = minor
entSensorThresholdSeverity.731.4 = critical
entSensorThresholdSeverity.741.1 = critical
entSensorThresholdSeverity.741.2 = minor
entSensorThresholdSeverity.741.3 = minor
entSensorThresholdSeverity.741.4 = critical
entSensorThresholdSeverity.742.1 = critical
entSensorThresholdSeverity.742.2 = minor
entSensorThresholdSeverity.742.3 = minor
entSensorThresholdSeverity.742.4 = critical
entSensorThresholdSeverity.743.1 = critical
entSensorThresholdSeverity.743.2 = minor
entSensorThresholdSeverity.743.3 = minor
entSensorThresholdSeverity.743.4 = critical
entSensorThresholdSeverity.744.1 = critical
entSensorThresholdSeverity.744.2 = minor
entSensorThresholdSeverity.744.3 = minor
entSensorThresholdSeverity.744.4 = critical
entSensorThresholdSeverity.745.1 = critical
entSensorThresholdSeverity.745.2 = minor
entSensorThresholdSeverity.745.3 = minor
entSensorThresholdSeverity.745.4 = critical
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entSensorThresholdRelation]

CMD EXITCODE[0]
CMD RUNTIME[0.0534s]
STDOUT[
entSensorThresholdRelation.11.1 = greaterOrEqual
entSensorThresholdRelation.11.2 = greaterOrEqual
entSensorThresholdRelation.11.3 = greaterOrEqual
entSensorThresholdRelation.11.4 = greaterOrEqual
entSensorThresholdRelation.12.1 = greaterOrEqual
entSensorThresholdRelation.12.2 = greaterOrEqual
entSensorThresholdRelation.12.3 = greaterOrEqual
entSensorThresholdRelation.12.4 = greaterOrEqual
entSensorThresholdRelation.31.1 = greaterOrEqual
entSensorThresholdRelation.31.2 = greaterOrEqual
entSensorThresholdRelation.31.3 = greaterOrEqual
entSensorThresholdRelation.31.4 = greaterOrEqual
entSensorThresholdRelation.32.1 = greaterOrEqual
entSensorThresholdRelation.32.2 = greaterOrEqual
entSensorThresholdRelation.32.3 = greaterOrEqual
entSensorThresholdRelation.32.4 = greaterOrEqual
entSensorThresholdRelation.111.1 = greaterOrEqual
entSensorThresholdRelation.111.2 = greaterOrEqual
entSensorThresholdRelation.111.3 = greaterOrEqual
entSensorThresholdRelation.111.4 = greaterOrEqual
entSensorThresholdRelation.112.1 = greaterOrEqual
entSensorThresholdRelation.112.2 = greaterOrEqual
entSensorThresholdRelation.112.3 = greaterOrEqual
entSensorThresholdRelation.532.4 = lessOrEqual
entSensorThresholdRelation.533.1 = greaterOrEqual
entSensorThresholdRelation.533.2 = greaterOrEqual
entSensorThresholdRelation.533.3 = lessOrEqual
entSensorThresholdRelation.533.4 = lessOrEqual
entSensorThresholdRelation.534.1 = greaterOrEqual
entSensorThresholdRelation.534.2 = greaterOrEqual
entSensorThresholdRelation.534.3 = lessOrEqual
entSensorThresholdRelation.534.4 = lessOrEqual
entSensorThresholdRelation.535.1 = greaterOrEqual
entSensorThresholdRelation.535.2 = greaterOrEqual
entSensorThresholdRelation.535.3 = lessOrEqual
entSensorThresholdRelation.535.4 = lessOrEqual
entSensorThresholdRelation.699.1 = greaterOrEqual
entSensorThresholdRelation.699.2 = greaterOrEqual
entSensorThresholdRelation.699.3 = lessOrEqual
entSensorThresholdRelation.699.4 = lessOrEqual
entSensorThresholdRelation.700.1 = greaterOrEqual
entSensorThresholdRelation.700.2 = greaterOrEqual
entSensorThresholdRelation.700.3 = lessOrEqual
entSensorThresholdRelation.700.4 = lessOrEqual
entSensorThresholdRelation.701.1 = greaterOrEqual
entSensorThresholdRelation.701.2 = greaterOrEqual
entSensorThresholdRelation.701.3 = lessOrEqual
entSensorThresholdRelation.701.4 = lessOrEqual
entSensorThresholdRelation.702.1 = greaterOrEqual
entSensorThresholdRelation.702.2 = greaterOrEqual
entSensorThresholdRelation.702.3 = lessOrEqual
entSensorThresholdRelation.702.4 = lessOrEqual
entSensorThresholdRelation.703.1 = greaterOrEqual
entSensorThresholdRelation.703.2 = greaterOrEqual
entSensorThresholdRelation.703.3 = lessOrEqual
entSensorThresholdRelation.703.4 = lessOrEqual
entSensorThresholdRelation.713.1 = greaterOrEqual
entSensorThresholdRelation.713.2 = greaterOrEqual
entSensorThresholdRelation.713.3 = lessOrEqual
entSensorThresholdRelation.713.4 = lessOrEqual
entSensorThresholdRelation.714.1 = greaterOrEqual
entSensorThresholdRelation.714.2 = greaterOrEqual
entSensorThresholdRelation.714.3 = lessOrEqual
entSensorThresholdRelation.714.4 = lessOrEqual
entSensorThresholdRelation.715.1 = greaterOrEqual
entSensorThresholdRelation.715.2 = greaterOrEqual
entSensorThresholdRelation.715.3 = lessOrEqual
entSensorThresholdRelation.715.4 = lessOrEqual
entSensorThresholdRelation.716.1 = greaterOrEqual
entSensorThresholdRelation.716.2 = greaterOrEqual
entSensorThresholdRelation.716.3 = lessOrEqual
entSensorThresholdRelation.716.4 = lessOrEqual
entSensorThresholdRelation.717.1 = greaterOrEqual
entSensorThresholdRelation.717.2 = greaterOrEqual
entSensorThresholdRelation.717.3 = lessOrEqual
entSensorThresholdRelation.717.4 = lessOrEqual
entSensorThresholdRelation.727.1 = greaterOrEqual
entSensorThresholdRelation.727.2 = greaterOrEqual
entSensorThresholdRelation.727.3 = lessOrEqual
entSensorThresholdRelation.727.4 = lessOrEqual
entSensorThresholdRelation.728.1 = greaterOrEqual
entSensorThresholdRelation.728.2 = greaterOrEqual
entSensorThresholdRelation.728.3 = lessOrEqual
entSensorThresholdRelation.728.4 = lessOrEqual
entSensorThresholdRelation.729.1 = greaterOrEqual
entSensorThresholdRelation.729.2 = greaterOrEqual
entSensorThresholdRelation.729.3 = lessOrEqual
entSensorThresholdRelation.729.4 = lessOrEqual
entSensorThresholdRelation.730.1 = greaterOrEqual
entSensorThresholdRelation.730.2 = greaterOrEqual
entSensorThresholdRelation.730.3 = lessOrEqual
entSensorThresholdRelation.730.4 = lessOrEqual
entSensorThresholdRelation.731.1 = greaterOrEqual
entSensorThresholdRelation.731.2 = greaterOrEqual
entSensorThresholdRelation.731.3 = lessOrEqual
entSensorThresholdRelation.731.4 = lessOrEqual
entSensorThresholdRelation.741.1 = greaterOrEqual
entSensorThresholdRelation.741.2 = greaterOrEqual
entSensorThresholdRelation.741.3 = lessOrEqual
entSensorThresholdRelation.741.4 = lessOrEqual
entSensorThresholdRelation.742.1 = greaterOrEqual
entSensorThresholdRelation.742.2 = greaterOrEqual
entSensorThresholdRelation.742.3 = lessOrEqual
entSensorThresholdRelation.742.4 = lessOrEqual
entSensorThresholdRelation.743.1 = greaterOrEqual
entSensorThresholdRelation.743.2 = greaterOrEqual
entSensorThresholdRelation.743.3 = lessOrEqual
entSensorThresholdRelation.743.4 = lessOrEqual
entSensorThresholdRelation.744.1 = greaterOrEqual
entSensorThresholdRelation.744.2 = greaterOrEqual
entSensorThresholdRelation.744.3 = lessOrEqual
entSensorThresholdRelation.744.4 = lessOrEqual
entSensorThresholdRelation.745.1 = greaterOrEqual
entSensorThresholdRelation.745.2 = greaterOrEqual
entSensorThresholdRelation.745.3 = lessOrEqual
entSensorThresholdRelation.745.4 = lessOrEqual
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entSensorThresholdValue]

CMD EXITCODE[0]
CMD RUNTIME[0.0604s]
STDOUT[
entSensorThresholdValue.11.1 = 90
entSensorThresholdValue.11.2 = 95
entSensorThresholdValue.11.3 = 100
entSensorThresholdValue.11.4 = 105
entSensorThresholdValue.12.1 = 100
entSensorThresholdValue.12.2 = 105
entSensorThresholdValue.12.3 = 110
entSensorThresholdValue.12.4 = 115
entSensorThresholdValue.31.1 = 90
entSensorThresholdValue.31.2 = 95
entSensorThresholdValue.31.3 = 100
entSensorThresholdValue.31.4 = 105
entSensorThresholdValue.32.1 = 100
entSensorThresholdValue.32.2 = 105
entSensorThresholdValue.32.3 = 110
entSensorThresholdValue.32.4 = 115
entSensorThresholdValue.111.1 = 100
entSensorThresholdValue.111.2 = 105
entSensorThresholdValue.111.3 = 110
entSensorThresholdValue.111.4 = 112
entSensorThresholdValue.112.1 = 85
entSensorThresholdValue.112.2 = 90
entSensorThresholdValue.112.3 = 93
entSensorThresholdValue.716.4 = -80
entSensorThresholdValue.717.1 = 0
entSensorThresholdValue.717.2 = -10
entSensorThresholdValue.717.3 = -144
entSensorThresholdValue.717.4 = -154
entSensorThresholdValue.727.1 = 100000
entSensorThresholdValue.727.2 = 95000
entSensorThresholdValue.727.3 = -5000
entSensorThresholdValue.727.4 = -10000
entSensorThresholdValue.728.1 = 38000
entSensorThresholdValue.728.2 = 36000
entSensorThresholdValue.728.3 = 30000
entSensorThresholdValue.728.4 = 28000
entSensorThresholdValue.729.1 = 100000
entSensorThresholdValue.729.2 = 90000
entSensorThresholdValue.729.3 = 9996
entSensorThresholdValue.729.4 = 0
entSensorThresholdValue.730.1 = 50
entSensorThresholdValue.730.2 = 40
entSensorThresholdValue.730.3 = -20
entSensorThresholdValue.730.4 = -30
entSensorThresholdValue.731.1 = -20
entSensorThresholdValue.731.2 = -30
entSensorThresholdValue.731.3 = -160
entSensorThresholdValue.731.4 = -180
entSensorThresholdValue.741.1 = 75000
entSensorThresholdValue.741.2 = 70000
entSensorThresholdValue.741.3 = 0
entSensorThresholdValue.741.4 = -5000
entSensorThresholdValue.742.1 = 35000
entSensorThresholdValue.742.2 = 34800
entSensorThresholdValue.742.3 = 31000
entSensorThresholdValue.742.4 = 30800
entSensorThresholdValue.743.1 = 90000
entSensorThresholdValue.743.2 = 80000
entSensorThresholdValue.743.3 = 4000
entSensorThresholdValue.743.4 = 2000
entSensorThresholdValue.744.1 = 0
entSensorThresholdValue.744.2 = -10
entSensorThresholdValue.744.3 = -60
entSensorThresholdValue.744.4 = -80
entSensorThresholdValue.745.1 = 0
entSensorThresholdValue.745.2 = -10
entSensorThresholdValue.745.3 = -144
entSensorThresholdValue.745.4 = -154
]
SNMP STATUS[TRUE]
Discover sensor: current, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7, 7, cisco-entity-sensor, ASR 920 250W DC Power Supply - PEM Iout - PEM Iout P0/0, SCALE: 1, LIMITS: (, , , ), CURRENT: 3, snmp, 7, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '7']
SQL RUNTIME[0.00042510s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '7']
SQL RUNTIME[0.00040078s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2508' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00013804s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.8, 8, cisco-entity-sensor, ASR 920 250W DC Power Supply - PEM Vout - PEM Vout P0/1, SCALE: 1, LIMITS: (, , , ), CURRENT: 13, snmp, 8, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '8']
SQL RUNTIME[0.00026894s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '8']
SQL RUNTIME[0.00031710s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2509' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011897s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.9, 9, cisco-entity-sensor, ASR 920 250W DC Power Supply - PEM Vin - PEM Vin P0/2, SCALE: 1, LIMITS: (, , , ), CURRENT: 54, snmp, 9, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '9']
SQL RUNTIME[0.00026107s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '9']
SQL RUNTIME[0.00031996s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2510' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012803s]
.Discover sensor: power, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.10, 10, cisco-entity-sensor, ASR 920 250W DC Power Supply - PEM Pin - PEM Pin P0/3, SCALE: 1, LIMITS: (, , , ), CURRENT: 43, snmp, 10, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'power' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '10']
SQL RUNTIME[0.00051403s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'power' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '10']
SQL RUNTIME[0.00051498s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2511' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00015497s]
.Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.11, 11, cisco-entity-sensor, ASR 920 250W DC Power Supply - Temp 3 - Temp 3 P0/4, SCALE: 1, LIMITS: (, , 90, 95), CURRENT: 34, snmp, 11, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '11']
SQL RUNTIME[0.00030708s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '11']
SQL RUNTIME[0.00031805s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2512' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012612s]
.Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.12, 12, cisco-entity-sensor, ASR 920 250W DC Power Supply - Temp 2 - Temp 2 P0/5, SCALE: 1, LIMITS: (, , 100, 105), CURRENT: 31, snmp, 12, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '12']
SQL RUNTIME[0.00026488s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '12']
SQL RUNTIME[0.00034308s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2513' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011802s]
.Discover sensor: current, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.27, 27, cisco-entity-sensor, ASR 920 250W DC Power Supply - PEM Iout - PEM Iout P1/0, SCALE: 1, LIMITS: (, , , ), CURRENT: 3, snmp, 27, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '27']
SQL RUNTIME[0.00035286s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '27']
SQL RUNTIME[0.00039601s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2514' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00013494s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.28, 28, cisco-entity-sensor, ASR 920 250W DC Power Supply - PEM Vout - PEM Vout P1/1, SCALE: 1, LIMITS: (, , , ), CURRENT: 13, snmp, 28, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '28']
SQL RUNTIME[0.00027180s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '28']
SQL RUNTIME[0.00035906s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2515' AND `attrib_type` = 'sensor_addition']
101']
SQL RUNTIME[0.00031018s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2521' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011516s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.102, 102, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VX2 - VADM1: VX2 R0/1, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 1.048, snmp, 102, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '102']
SQL RUNTIME[0.00025702s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '102']
SQL RUNTIME[0.00032997s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2522' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011420s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.103, 103, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VX3 - VADM1: VX3 R0/2, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 0.996, snmp, 103, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '103']
SQL RUNTIME[0.00026011s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '103']
SQL RUNTIME[0.00033307s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2523' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00014782s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.104, 104, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VP1 - VADM1: VP1 R0/3, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 3.294, snmp, 104, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '104']
SQL RUNTIME[0.00025296s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '104']
SQL RUNTIME[0.00032997s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2524' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00025415s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.105, 105, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VP2 - VADM1: VP2 R0/4, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 1.796, snmp, 105, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '105']
SQL RUNTIME[0.00025511s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '105']
SQL RUNTIME[0.00033593s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2525' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00016618s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.106, 106, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VP3 - VADM1: VP3 R0/5, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 1.199, snmp, 106, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '106']
SQL RUNTIME[0.00024915s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '106']
SQL RUNTIME[0.00033998s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2526' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011897s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.107, 107, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VP4 - VADM1: VP4 R0/6, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 1.771, snmp, 107, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '107']
SQL RUNTIME[0.00028706s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '107']
SQL RUNTIME[0.00032020s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2527' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012684s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.108, 108, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VH - VADM1: VH R0/7, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 12.495, snmp, 108, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '108']
SQL RUNTIME[0.00025082s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '108']
SQL RUNTIME[0.00031996s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2528' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011587s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.109, 109, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: AUX1 - VADM1: AUX1 R0/8, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 4.971, snmp, 109, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '109']
SQL RUNTIME[0.00025201s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '109']
SQL RUNTIME[0.00032020s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2529' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011706s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.110, 110, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: AUX2 - VADM1: AUX2 R0/9, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 6.93, snmp, 110, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '110']
SQL RUNTIME[0.00026107s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '110']
SQL RUNTIME[0.00032806s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2530' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012398s]
.Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.111, 111, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - CYLON - CYLON R0/10, SCALE: 1, LIMITS: (, , 100, 105), CURRENT: 84, snmp, 111, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '111']
SQL RUNTIME[0.00026393s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '111']
SQL RUNTIME[0.00030708s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2531' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00015306s]
.Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.112, 112, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - BOARD - BOARD R0/11, SCALE: 1, LIMITS: (, , 85, 90), CURRENT: 47, snmp, 112, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '112']
SQL RUNTIME[0.00025606s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '112']
SQL RUNTIME[0.00030613s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2532' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00014615s]
.Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.113, 113, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - Outlet - Outlet R0/12, SCALE: 1, LIMITS: (, , 80, 85), CURRENT: 43, snmp, 113, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
SQL RUNTIME[0.00012589s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.117, 117, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM2: VX3 - VADM2: VX3 R0/16, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 0.753, snmp, 117, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '117']
SQL RUNTIME[0.00026107s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '117']
SQL RUNTIME[0.00035000s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2537' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012589s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.118, 118, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM2: VP1 - VADM2: VP1 R0/17, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 2.496, snmp, 118, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '118']
SQL RUNTIME[0.00026011s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '118']
SQL RUNTIME[0.00035310s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2538' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00013399s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.119, 119, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM2: VP2 - VADM2: VP2 R0/18, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 1.497, snmp, 119, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '119']
SQL RUNTIME[0.00026083s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '119']
SQL RUNTIME[0.00034285s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2539' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00013685s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.120, 120, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM2: VP3 - VADM2: VP3 R0/19, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 1.495, snmp, 120, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '120']
SQL RUNTIME[0.00026011s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '120']
SQL RUNTIME[0.00033593s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2540' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00013399s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.121, 121, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM2: VH - VADM2: VH R0/20, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 12.485, snmp, 121, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '121']
SQL RUNTIME[0.00025201s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '121']
SQL RUNTIME[0.00032091s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2541' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012493s]
.Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.122, 122, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - Inlet - Inlet R0/21, SCALE: 1, LIMITS: (, , 75, 77), CURRENT: 36, snmp, 122, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '122']
SQL RUNTIME[0.00028896s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '122']
SQL RUNTIME[0.00032592s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2542' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011706s]
.Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.377, 377, cisco-entity-sensor, subslot 0/0 transceiver 1 Temperature, SCALE: 0.001, LIMITS: (, 0, 75, ), CURRENT: 29.375, snmp, 377, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '377']
SQL RUNTIME[0.00027990s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '377']
SQL RUNTIME[0.00031519s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '41404' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011706s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.378, 378, cisco-entity-sensor, subslot 0/0 transceiver 1 Supply Voltage, SCALE: 0.0001, LIMITS: (, 3.15, 3.47, ), CURRENT: 3.3187, snmp, 378, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '378']
SQL RUNTIME[0.00029302s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '378']
SQL RUNTIME[0.00033998s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '41405' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012398s]
.Discover sensor: current, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.379, 379, cisco-entity-sensor, subslot 0/0 transceiver 1 Bias Current, SCALE: 1.0E-6, LIMITS: (, 0.004, 0.08, ), CURRENT: 0.01898, snmp, 379, 
Skipped by regexp: /.*subslot\ 0\/[0-9]\ transceiver\ [0-9][0-9]?\ Bias Current/, subslot 0/0 transceiver 1 Bias Current 
Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.380, 380, cisco-entity-sensor, subslot 0/0 transceiver 1 Tx Power, SCALE: 0.1, LIMITS: (, -9, -3, ), CURRENT: -5.9, snmp, 380, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '380']
SQL RUNTIME[0.00026989s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '380']
SQL RUNTIME[0.00030708s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '41406' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012612s]
.Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.381, 381, cisco-entity-sensor, subslot 0/0 transceiver 1 Rx Power, SCALE: 0.1, LIMITS: (, -20, -3, ), CURRENT: -4.6, snmp, 381, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '381']
SQL RUNTIME[0.00028300s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '381']
SQL RUNTIME[0.00032115s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '41407' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012612s]
.Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.531, 531, cisco-entity-sensor, subslot 0/0 transceiver 12 Temperature, SCALE: 0.001, LIMITS: (, 0, 75, ), CURRENT: 28.648, snmp, 531, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '531']
SQL RUNTIME[0.00026298s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '531']
SQL RUNTIME[0.00032902s]

LIMITS: (, -20, -3, ), CURRENT: -9.2, snmp, 535, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '535']
SQL RUNTIME[0.00024581s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '535']
SQL RUNTIME[0.00030494s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28001' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00014615s]
.Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.699, 699, cisco-entity-sensor, subslot 0/0 transceiver 24 Temperature, SCALE: 0.001, LIMITS: (, 0, 70, ), CURRENT: 38.515, snmp, 699, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '699']
SQL RUNTIME[0.00026608s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '699']
SQL RUNTIME[0.00031400s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2548' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00014806s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.700, 700, cisco-entity-sensor, subslot 0/0 transceiver 24 Supply Voltage, SCALE: 0.0001, LIMITS: (, 3.1, 3.48, ), CURRENT: 3.2854, snmp, 700, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '700']
SQL RUNTIME[0.00027108s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '700']
SQL RUNTIME[0.00031996s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2549' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00015092s]
.Discover sensor: current, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.701, 701, cisco-entity-sensor, subslot 0/0 transceiver 24 Bias Current, SCALE: 1.0E-6, LIMITS: (, 0.004, 0.08, ), CURRENT: 0.040808, snmp, 701, 
Skipped by regexp: /.*subslot\ 0\/[0-9]\ transceiver\ [0-9][0-9]?\ Bias Current/, subslot 0/0 transceiver 24 Bias Current 
Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.702, 702, cisco-entity-sensor, subslot 0/0 transceiver 24 Tx Power, SCALE: 0.1, LIMITS: (, -6, -1, ), CURRENT: -3.1, snmp, 702, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '702']
SQL RUNTIME[0.00026894s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '702']
SQL RUNTIME[0.00031209s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2551' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011611s]
.Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.703, 703, cisco-entity-sensor, subslot 0/0 transceiver 24 Rx Power, SCALE: 0.1, LIMITS: (, -14.4, -1, ), CURRENT: -2.2, snmp, 703, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '703']
SQL RUNTIME[0.00025702s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '703']
SQL RUNTIME[0.00031805s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2552' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012708s]
.Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.713, 713, cisco-entity-sensor, subslot 0/0 transceiver 25 Temperature, SCALE: 0.001, LIMITS: (, 0, 70, ), CURRENT: 37.835, snmp, 713, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '713']
SQL RUNTIME[0.00026703s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '713']
SQL RUNTIME[0.00034213s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2553' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012612s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.714, 714, cisco-entity-sensor, subslot 0/0 transceiver 25 Supply Voltage, SCALE: 0.0001, LIMITS: (, 3.1, 3.48, ), CURRENT: 3.276, snmp, 714, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '714']
SQL RUNTIME[0.00027490s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '714']
SQL RUNTIME[0.00034904s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2554' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012517s]
.Discover sensor: current, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.715, 715, cisco-entity-sensor, subslot 0/0 transceiver 25 Bias Current, SCALE: 1.0E-6, LIMITS: (, 0.004, 0.08, ), CURRENT: 0.039808, snmp, 715, 
Skipped by regexp: /.*subslot\ 0\/[0-9]\ transceiver\ [0-9][0-9]?\ Bias Current/, subslot 0/0 transceiver 25 Bias Current 
Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.716, 716, cisco-entity-sensor, subslot 0/0 transceiver 25 Tx Power, SCALE: 0.1, LIMITS: (, -6, -1, ), CURRENT: -2.8, snmp, 716, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '716']
SQL RUNTIME[0.00024009s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '716']
SQL RUNTIME[0.00031304s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2556' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012398s]
.Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.717, 717, cisco-entity-sensor, subslot 0/0 transceiver 25 Rx Power, SCALE: 0.1, LIMITS: (, -14.4, -1, ), CURRENT: -2.4, snmp, 717, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '717']
SQL RUNTIME[0.00024509s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '717']
SQL RUNTIME[0.00033498s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2557' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012493s]
.Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.727, 727, cisco-entity-sensor, subslot 0/0 transceiver 26 Temperature, SCALE: 0.001, LIMITS: (, -5, 95, ), CURRENT: 45.554, snmp, 727, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '727']
SQL RUNTIME[0.00025320s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '727']
SQL RUNTIME[0.00035000s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2558' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00013614s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.728, 728, cisco-entity-sensor, subslot 0/0 transceiver 26 Supply Voltage, SCALE: 0.0001, LIMITS: (, 3, 3.6, ), CURRENT: 3.3531, snmp, 728, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '728']
SQL RUNTIME[0.00025702s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '728']
SQL RUNTIME[0.00034809s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2559' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00013399s]
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '730']
SQL RUNTIME[0.00117683s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '730']
SQL RUNTIME[0.00051188s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2561' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00017905s]
.Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.731, 731, cisco-entity-sensor, subslot 0/0 transceiver 26 Rx Power, SCALE: 0.1, LIMITS: (, -16, -3, ), CURRENT: -2.5, snmp, 731, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '731']
SQL RUNTIME[0.00040007s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '731']
SQL RUNTIME[0.00053596s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2562' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00019097s]
.Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.741, 741, cisco-entity-sensor, subslot 0/0 transceiver 27 Temperature, SCALE: 0.001, LIMITS: (, 0, 70, ), CURRENT: 38.531, snmp, 741, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '741']
SQL RUNTIME[0.00040913s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '741']
SQL RUNTIME[0.00052309s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28002' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00020313s]
.Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.742, 742, cisco-entity-sensor, subslot 0/0 transceiver 27 Supply Voltage, SCALE: 0.0001, LIMITS: (, 3.1, 3.48, ), CURRENT: 3.2948, snmp, 742, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '742']
SQL RUNTIME[0.00516415s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '742']
SQL RUNTIME[0.00048399s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28003' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00015998s]
.Discover sensor: current, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.743, 743, cisco-entity-sensor, subslot 0/0 transceiver 27 Bias Current, SCALE: 1.0E-6, LIMITS: (, 0.004, 0.08, ), CURRENT: 0.034682, snmp, 743, 
Skipped by regexp: /.*subslot\ 0\/[0-9]\ transceiver\ [0-9][0-9]?\ Bias Current/, subslot 0/0 transceiver 27 Bias Current 
Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.744, 744, cisco-entity-sensor, subslot 0/0 transceiver 27 Tx Power, SCALE: 0.1, LIMITS: (, -6, -1, ), CURRENT: -2.7, snmp, 744, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '744']
SQL RUNTIME[0.00027990s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '744']
SQL RUNTIME[0.00031400s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28004' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012898s]
.Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.745, 745, cisco-entity-sensor, subslot 0/0 transceiver 27 Rx Power, SCALE: 0.1, LIMITS: (, -14.4, -1, ), CURRENT: -1.3, snmp, 745, 

SQL[SELECT COUNT(`sensor_id`) FROM `sensors`
                   WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '745']
SQL RUNTIME[0.00028110s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '745']
SQL RUNTIME[0.00034285s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28005' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00013304s]
.
 o CISCO-ENVMON-MIB     
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENVMON-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' ciscoEnvMonTemperatureStatusEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0194s]
STDOUT[
ciscoEnvMonTemperatureStatusEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENVMON-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' ciscoEnvMonVoltageStatusEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0186s]
STDOUT[
ciscoEnvMonVoltageStatusEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENVMON-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' ciscoEnvMonSupplyStatusEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0213s]
STDOUT[
ciscoEnvMonSupplyStatusEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
 Fans 
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENVMON-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' ciscoEnvMonFanStatusEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0188s]
STDOUT[
ciscoEnvMonFanStatusEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o CISCO-ENTITY-FRU-CONTROL-MIB  CISCO-ENTITY-FRU-CONTROL-MIB 
SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '41' AND `status_type` = 'cisco-envmon-state';]
entPhysicalDescr.108 = VADM1: VH
entPhysicalDescr.109 = VADM1: AUX1
entPhysicalDescr.110 = VADM1: AUX2
entPhysicalDescr.111 = Temp: CYLON   
entPhysicalDescr.112 = Temp: BOARD   
entPhysicalDescr.113 = Temp: Outlet  
entPhysicalDescr.114 = Temp: CPU     
entPhysicalDescr.115 = VADM2: VX1
entPhysicalDescr.116 = VADM2: VX2
entPhysicalDescr.117 = VADM2: VX3
entPhysicalDescr.118 = VADM2: VP1
entPhysicalDescr.119 = VADM2: VP2
entPhysicalDescr.120 = VADM2: VP3
entPhysicalDescr.121 = VADM2: VH
entPhysicalDescr.122 = Temp: Inlet   
entPhysicalDescr.130 = CYLON   
entPhysicalDescr.131 = CPU 0 of module R0
entPhysicalDescr.132 = USB Port
entPhysicalDescr.134 = USB Port
entPhysicalDescr.136 = Network Management Ethernet
entPhysicalDescr.300 = FIXED : 24-port Gig & 4-port Ten Gig SFP Ethernet Interface Module
entPhysicalDescr.359 = subslot 0/0 transceiver container 0
entPhysicalDescr.373 = subslot 0/0 transceiver container 1
entPhysicalDescr.374 = GE LX
entPhysicalDescr.375 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.377 = subslot 0/0 transceiver 1 Temperature Sensor
entPhysicalDescr.378 = subslot 0/0 transceiver 1 Supply Voltage Sensor
entPhysicalDescr.379 = subslot 0/0 transceiver 1 Bias Current Sensor
entPhysicalDescr.380 = subslot 0/0 transceiver 1 Tx Power Sensor
entPhysicalDescr.381 = subslot 0/0 transceiver 1 Rx Power Sensor
entPhysicalDescr.387 = subslot 0/0 transceiver container 2
entPhysicalDescr.401 = subslot 0/0 transceiver container 3
entPhysicalDescr.415 = subslot 0/0 transceiver container 4
entPhysicalDescr.429 = subslot 0/0 transceiver container 5
entPhysicalDescr.443 = subslot 0/0 transceiver container 6
entPhysicalDescr.457 = subslot 0/0 transceiver container 7
entPhysicalDescr.471 = subslot 0/0 transceiver container 8
entPhysicalDescr.485 = subslot 0/0 transceiver container 9
entPhysicalDescr.499 = subslot 0/0 transceiver container 10
entPhysicalDescr.513 = subslot 0/0 transceiver container 11
entPhysicalDescr.527 = subslot 0/0 transceiver container 12
entPhysicalDescr.528 = GE LX
entPhysicalDescr.529 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.531 = subslot 0/0 transceiver 12 Temperature Sensor
entPhysicalDescr.532 = subslot 0/0 transceiver 12 Supply Voltage Sensor
entPhysicalDescr.533 = subslot 0/0 transceiver 12 Bias Current Sensor
entPhysicalDescr.534 = subslot 0/0 transceiver 12 Tx Power Sensor
entPhysicalDescr.535 = subslot 0/0 transceiver 12 Rx Power Sensor
entPhysicalDescr.541 = subslot 0/0 transceiver container 13
entPhysicalDescr.555 = subslot 0/0 transceiver container 14
entPhysicalDescr.569 = subslot 0/0 transceiver container 15
entPhysicalDescr.583 = subslot 0/0 transceiver container 16
entPhysicalDescr.597 = subslot 0/0 transceiver container 17
entPhysicalDescr.611 = subslot 0/0 transceiver container 18
entPhysicalDescr.625 = subslot 0/0 transceiver container 19
entPhysicalDescr.639 = subslot 0/0 transceiver container 20
entPhysicalDescr.653 = subslot 0/0 transceiver container 21
entPhysicalDescr.667 = subslot 0/0 transceiver container 22
entPhysicalDescr.668 = GE T
entPhysicalDescr.669 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.681 = subslot 0/0 transceiver container 23
entPhysicalDescr.695 = subslot 0/0 transceiver container 24
entPhysicalDescr.696 = SFP+ 10GBASE-LR
entPhysicalDescr.697 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.699 = subslot 0/0 transceiver 24 Temperature Sensor
entPhysicalDescr.700 = subslot 0/0 transceiver 24 Supply Voltage Sensor
entPhysicalDescr.701 = subslot 0/0 transceiver 24 Bias Current Sensor
entPhysicalDescr.702 = subslot 0/0 transceiver 24 Tx Power Sensor
entPhysicalDescr.703 = subslot 0/0 transceiver 24 Rx Power Sensor
entPhysicalDescr.709 = subslot 0/0 transceiver container 25
entPhysicalDescr.710 = SFP+ 10GBASE-LR
entPhysicalDescr.711 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.713 = subslot 0/0 transceiver 25 Temperature Sensor
entPhysicalDescr.714 = subslot 0/0 transceiver 25 Supply Voltage Sensor
entPhysicalDescr.715 = subslot 0/0 transceiver 25 Bias Current Sensor
entPhysicalDescr.716 = subslot 0/0 transceiver 25 Tx Power Sensor
entPhysicalDescr.717 = subslot 0/0 transceiver 25 Rx Power Sensor
entPhysicalDescr.723 = subslot 0/0 transceiver container 26
entPhysicalDescr.724 = SFP+ 10GBASE-ER
entPhysicalDescr.725 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.727 = subslot 0/0 transceiver 26 Temperature Sensor
entPhysicalDescr.728 = subslot 0/0 transceiver 26 Supply Voltage Sensor
entPhysicalDescr.729 = subslot 0/0 transceiver 26 Bias Current Sensor
entPhysicalDescr.730 = subslot 0/0 transceiver 26 Tx Power Sensor
entPhysicalDescr.731 = subslot 0/0 transceiver 26 Rx Power Sensor
entPhysicalDescr.737 = subslot 0/0 transceiver container 27
entPhysicalDescr.738 = SFP+ 10GBASE-LR
entPhysicalDescr.739 = 24xGE-4x10GE-FIXED-S
entPhysicalDescr.741 = subslot 0/0 transceiver 27 Temperature Sensor
entPhysicalDescr.742 = subslot 0/0 transceiver 27 Supply Voltage Sensor
entPhysicalDescr.743 = subslot 0/0 transceiver 27 Bias Current Sensor
entPhysicalDescr.744 = subslot 0/0 transceiver 27 Tx Power Sensor
entPhysicalDescr.745 = subslot 0/0 transceiver 27 Rx Power Sensor
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalName]

CMD EXITCODE[0]
CMD RUNTIME[0.0834s]
STDOUT[
entPhysicalName.1 = Chassis
entPhysicalName.2 = slot R0
entPhysicalName.3 = subslot 0/0
entPhysicalName.4 = subslot 0/1
entPhysicalName.5 = Power Supply Bay 0
entPhysicalName.6 = Power Supply Module 0
entPhysicalName.7 = PEM Iout P0/0
entPhysicalName.8 = PEM Vout P0/1
entPhysicalName.9 = PEM Vin P0/2
entPhysicalName.10 = PEM Pin P0/3
entPhysicalName.11 = Temp: Temp 3   P0/4
entPhysicalName.12 = Temp: Temp 2   P0/5
entPhysicalName.25 = Power Supply Bay 1
entPhysicalName.26 = Power Supply Module 1
entPhysicalName.27 = PEM Iout P1/0
entPhysicalName.28 = PEM Vout P1/1
entPhysicalName.29 = PEM Vin P1/2
entPhysicalName.30 = PEM Pin P1/3
entPhysicalName.31 = Temp: Temp 3   P1/4
entPhysicalName.32 = Temp: Temp 2   P1/5
entPhysicalName.45 = Fan Tray Bay 0
entPhysicalName.46 = Fan Tray
entPhysicalName.47 = Temp: FC PWM  P2/0
entPhysicalName.108 = VADM1: VH R0/7
entPhysicalName.109 = VADM1: AUX1 R0/8
entPhysicalName.110 = VADM1: AUX2 R0/9
entPhysicalName.111 = Temp: CYLON    R0/10
entPhysicalName.112 = Temp: BOARD    R0/11
entPhysicalName.113 = Temp: Outlet   R0/12
entPhysicalName.114 = Temp: CPU      R0/13
entPhysicalName.115 = VADM2: VX1 R0/14
entPhysicalName.116 = VADM2: VX2 R0/15
entPhysicalName.117 = VADM2: VX3 R0/16
entPhysicalName.118 = VADM2: VP1 R0/17
entPhysicalName.119 = VADM2: VP2 R0/18
entPhysicalName.120 = VADM2: VP3 R0/19
entPhysicalName.121 = VADM2: VH R0/20
entPhysicalName.122 = Temp: Inlet    R0/21
entPhysicalName.130 = CYLON   
entPhysicalName.131 = cpu R0/0
entPhysicalName.132 = usb R0/0
entPhysicalName.134 = usb R0/1
entPhysicalName.136 = NME R0
entPhysicalName.300 =  FIXED IM subslot 0/0
entPhysicalName.359 = subslot 0/0 transceiver container 0
entPhysicalName.373 = subslot 0/0 transceiver container 1
entPhysicalName.374 = subslot 0/0 transceiver 1
entPhysicalName.375 = GigabitEthernet0/0/1
entPhysicalName.377 = subslot 0/0 transceiver 1 Temperature Sensor
entPhysicalName.378 = subslot 0/0 transceiver 1 Supply Voltage Sensor
entPhysicalName.379 = subslot 0/0 transceiver 1 Bias Current Sensor
entPhysicalName.380 = subslot 0/0 transceiver 1 Tx Power Sensor
entPhysicalName.381 = subslot 0/0 transceiver 1 Rx Power Sensor
entPhysicalName.387 = subslot 0/0 transceiver container 2
entPhysicalName.401 = subslot 0/0 transceiver container 3
entPhysicalName.415 = subslot 0/0 transceiver container 4
entPhysicalName.429 = subslot 0/0 transceiver container 5
entPhysicalName.443 = subslot 0/0 transceiver container 6
entPhysicalName.457 = subslot 0/0 transceiver container 7
entPhysicalName.471 = subslot 0/0 transceiver container 8
entPhysicalName.485 = subslot 0/0 transceiver container 9
entPhysicalName.499 = subslot 0/0 transceiver container 10
entPhysicalName.513 = subslot 0/0 transceiver container 11
entPhysicalName.527 = subslot 0/0 transceiver container 12
entPhysicalName.528 = subslot 0/0 transceiver 12
entPhysicalName.529 = GigabitEthernet0/0/12
entPhysicalName.531 = subslot 0/0 transceiver 12 Temperature Sensor
entPhysicalName.532 = subslot 0/0 transceiver 12 Supply Voltage Sensor
entPhysicalName.533 = subslot 0/0 transceiver 12 Bias Current Sensor
entPhysicalName.534 = subslot 0/0 transceiver 12 Tx Power Sensor
entPhysicalName.535 = subslot 0/0 transceiver 12 Rx Power Sensor
entPhysicalName.541 = subslot 0/0 transceiver container 13
entPhysicalName.555 = subslot 0/0 transceiver container 14
entPhysicalName.569 = subslot 0/0 transceiver container 15
entPhysicalName.583 = subslot 0/0 transceiver container 16
entPhysicalName.597 = subslot 0/0 transceiver container 17
entPhysicalName.611 = subslot 0/0 transceiver container 18
entPhysicalName.625 = subslot 0/0 transceiver container 19
entPhysicalName.639 = subslot 0/0 transceiver container 20
entPhysicalName.653 = subslot 0/0 transceiver container 21
entPhysicalName.667 = subslot 0/0 transceiver container 22
entPhysicalName.668 = subslot 0/0 transceiver 22
entPhysicalName.669 = GigabitEthernet0/0/22
entPhysicalName.681 = subslot 0/0 transceiver container 23
entPhysicalName.695 = subslot 0/0 transceiver container 24
entPhysicalName.696 = subslot 0/0 transceiver 24
entPhysicalName.697 = TenGigabitEthernet0/0/24
entPhysicalName.699 = subslot 0/0 transceiver 24 Temperature Sensor
entPhysicalName.700 = subslot 0/0 transceiver 24 Supply Voltage Sensor
entPhysicalName.701 = subslot 0/0 transceiver 24 Bias Current Sensor
entPhysicalName.702 = subslot 0/0 transceiver 24 Tx Power Sensor
entPhysicalName.703 = subslot 0/0 transceiver 24 Rx Power Sensor
entPhysicalName.709 = subslot 0/0 transceiver container 25
entPhysicalName.710 = subslot 0/0 transceiver 25
entPhysicalName.711 = TenGigabitEthernet0/0/25
entPhysicalName.713 = subslot 0/0 transceiver 25 Temperature Sensor
entPhysicalName.714 = subslot 0/0 transceiver 25 Supply Voltage Sensor
entPhysicalName.715 = subslot 0/0 transceiver 25 Bias Current Sensor
entPhysicalName.716 = subslot 0/0 transceiver 25 Tx Power Sensor
entPhysicalName.717 = subslot 0/0 transceiver 25 Rx Power Sensor
entPhysicalName.723 = subslot 0/0 transceiver container 26
entPhysicalName.724 = subslot 0/0 transceiver 26
entPhysicalName.725 = TenGigabitEthernet0/0/26
entPhysicalName.727 = subslot 0/0 transceiver 26 Temperature Sensor
entPhysicalName.728 = subslot 0/0 transceiver 26 Supply Voltage Sensor
entPhysicalName.729 = subslot 0/0 transceiver 26 Bias Current Sensor
entPhysicalName.730 = subslot 0/0 transceiver 26 Tx Power Sensor
entPhysicalName.731 = subslot 0/0 transceiver 26 Rx Power Sensor
entPhysicalName.737 = subslot 0/0 transceiver container 27
entPhysicalName.738 = subslot 0/0 transceiver 27
entPhysicalName.739 = TenGigabitEthernet0/0/27
entPhysicalName.741 = subslot 0/0 transceiver 27 Temperature Sensor
entPhysicalName.742 = subslot 0/0 transceiver 27 Supply Voltage Sensor
entPhysicalName.743 = subslot 0/0 transceiver 27 Bias Current Sensor
entPhysicalName.744 = subslot 0/0 transceiver 27 Tx Power Sensor
entPhysicalName.745 = subslot 0/0 transceiver 27 Rx Power Sensor
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalClass]

CMD EXITCODE[0]
CMD RUNTIME[0.0762s]
STDOUT[
entPhysicalClass.1 = chassis
entPhysicalClass.2 = container
entPhysicalClass.3 = container
entPhysicalClass.4 = container
entPhysicalClass.5 = container
entPhysicalClass.6 = powerSupply
entPhysicalClass.7 = sensor
entPhysicalClass.8 = sensor
entPhysicalClass.9 = sensor
entPhysicalClass.10 = sensor
entPhysicalClass.11 = sensor
entPhysicalClass.12 = sensor
entPhysicalClass.25 = container
entPhysicalClass.26 = powerSupply
entPhysicalClass.27 = sensor
entPhysicalClass.28 = sensor
entPhysicalClass.29 = sensor
entPhysicalClass.30 = sensor
entPhysicalClass.31 = sensor
entPhysicalClass.32 = sensor
entPhysicalClass.45 = container
entPhysicalClass.46 = fan
entPhysicalClass.47 = sensor
entPhysicalClass.108 = sensor
entPhysicalClass.109 = sensor
entPhysicalClass.110 = sensor
entPhysicalClass.111 = sensor
entPhysicalClass.112 = sensor
entPhysicalClass.113 = sensor
entPhysicalClass.114 = sensor
entPhysicalClass.115 = sensor
entPhysicalClass.116 = sensor
entPhysicalClass.117 = sensor
entPhysicalClass.118 = sensor
entPhysicalClass.119 = sensor
entPhysicalClass.120 = sensor
entPhysicalClass.121 = sensor
entPhysicalClass.122 = sensor
entPhysicalClass.130 = cpu
entPhysicalClass.131 = cpu
entPhysicalClass.132 = container
entPhysicalClass.134 = container
entPhysicalClass.136 = port
entPhysicalClass.300 = module
entPhysicalClass.359 = container
entPhysicalClass.373 = container
entPhysicalClass.374 = module
entPhysicalClass.375 = port
entPhysicalClass.377 = sensor
entPhysicalClass.378 = sensor
entPhysicalClass.379 = sensor
entPhysicalClass.380 = sensor
entPhysicalClass.381 = sensor
entPhysicalClass.387 = container
entPhysicalClass.401 = container
entPhysicalClass.415 = container
entPhysicalClass.429 = container
entPhysicalClass.443 = container
entPhysicalClass.457 = container
entPhysicalClass.471 = container
entPhysicalClass.485 = container
entPhysicalClass.499 = container
entPhysicalClass.513 = container
entPhysicalClass.527 = container
entPhysicalClass.528 = module
entPhysicalClass.529 = port
entPhysicalClass.531 = sensor
entPhysicalClass.532 = sensor
entPhysicalClass.533 = sensor
entPhysicalClass.534 = sensor
entPhysicalClass.535 = sensor
entPhysicalClass.541 = container
entPhysicalClass.555 = container
entPhysicalClass.569 = container
entPhysicalClass.583 = container
entPhysicalClass.597 = container
entPhysicalClass.611 = container
entPhysicalClass.625 = container
entPhysicalClass.639 = container
entPhysicalClass.653 = container
entPhysicalClass.667 = container
entPhysicalClass.668 = module
entPhysicalClass.669 = port
entPhysicalClass.681 = container
entPhysicalClass.695 = container
entPhysicalClass.696 = module
entPhysicalClass.697 = port
entPhysicalClass.699 = sensor
entPhysicalClass.700 = sensor
entPhysicalClass.701 = sensor
entPhysicalClass.702 = sensor
entPhysicalClass.703 = sensor
entPhysicalClass.709 = container
entPhysicalClass.710 = module
entPhysicalClass.711 = port
entPhysicalClass.713 = sensor
entPhysicalClass.714 = sensor
entPhysicalClass.715 = sensor
entPhysicalClass.716 = sensor
entPhysicalClass.717 = sensor
entPhysicalClass.723 = container
entPhysicalClass.724 = module
entPhysicalClass.725 = port
entPhysicalClass.727 = sensor
entPhysicalClass.728 = sensor
entPhysicalClass.729 = sensor
entPhysicalClass.730 = sensor
entPhysicalClass.731 = sensor
entPhysicalClass.737 = container
entPhysicalClass.738 = module
entPhysicalClass.739 = port
entPhysicalClass.741 = sensor
entPhysicalClass.742 = sensor
entPhysicalClass.743 = sensor
entPhysicalClass.744 = sensor
entPhysicalClass.745 = sensor
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalContainedIn]

CMD EXITCODE[0]
CMD RUNTIME[0.0818s]
STDOUT[
entPhysicalContainedIn.1 = 0
entPhysicalContainedIn.2 = 1
entPhysicalContainedIn.3 = 1
entPhysicalContainedIn.4 = 1
entPhysicalContainedIn.5 = 1
entPhysicalContainedIn.6 = 5
entPhysicalContainedIn.7 = 6
entPhysicalContainedIn.8 = 6
entPhysicalContainedIn.9 = 6
entPhysicalContainedIn.10 = 6
entPhysicalContainedIn.11 = 6
entPhysicalContainedIn.12 = 6
entPhysicalContainedIn.25 = 1
entPhysicalContainedIn.26 = 25
entPhysicalContainedIn.27 = 26
entPhysicalContainedIn.28 = 26
entPhysicalContainedIn.29 = 26
entPhysicalContainedIn.30 = 26
entPhysicalContainedIn.31 = 26
entPhysicalContainedIn.32 = 26
entPhysicalContainedIn.45 = 1
entPhysicalContainedIn.46 = 45
entPhysicalContainedIn.47 = 46
entPhysicalContainedIn.108 = 100
entPhysicalContainedIn.109 = 100
entPhysicalContainedIn.110 = 100
entPhysicalContainedIn.111 = 100
entPhysicalContainedIn.112 = 100
entPhysicalContainedIn.113 = 100
entPhysicalContainedIn.114 = 100
entPhysicalContainedIn.115 = 100
entPhysicalContainedIn.116 = 100
entPhysicalContainedIn.117 = 100
entPhysicalContainedIn.118 = 100
entPhysicalContainedIn.119 = 100
entPhysicalContainedIn.120 = 100
entPhysicalContainedIn.121 = 100
entPhysicalContainedIn.122 = 100
entPhysicalContainedIn.130 = 100
entPhysicalContainedIn.131 = 100
entPhysicalContainedIn.132 = 100
entPhysicalContainedIn.134 = 100
entPhysicalContainedIn.136 = 100
entPhysicalContainedIn.300 = 3
entPhysicalContainedIn.359 = 300
entPhysicalContainedIn.373 = 300
entPhysicalContainedIn.374 = 373
entPhysicalContainedIn.375 = 374
entPhysicalContainedIn.377 = 374
entPhysicalContainedIn.378 = 374
entPhysicalContainedIn.379 = 374
entPhysicalContainedIn.380 = 374
entPhysicalContainedIn.381 = 374
entPhysicalContainedIn.387 = 300
entPhysicalContainedIn.401 = 300
entPhysicalContainedIn.415 = 300
entPhysicalContainedIn.429 = 300
entPhysicalContainedIn.443 = 300
entPhysicalContainedIn.457 = 300
entPhysicalContainedIn.471 = 300
entPhysicalContainedIn.485 = 300
entPhysicalContainedIn.499 = 300
entPhysicalContainedIn.513 = 300
entPhysicalContainedIn.527 = 300
entPhysicalContainedIn.528 = 527
entPhysicalContainedIn.529 = 528
entPhysicalContainedIn.531 = 528
entPhysicalContainedIn.532 = 528
entPhysicalContainedIn.533 = 528
entPhysicalContainedIn.534 = 528
entPhysicalContainedIn.535 = 528
entPhysicalContainedIn.541 = 300
entPhysicalContainedIn.555 = 300
entPhysicalContainedIn.569 = 300
entPhysicalContainedIn.583 = 300
entPhysicalContainedIn.597 = 300
entPhysicalContainedIn.611 = 300
entPhysicalContainedIn.625 = 300
entPhysicalContainedIn.639 = 300
entPhysicalContainedIn.653 = 300
entPhysicalContainedIn.667 = 300
entPhysicalContainedIn.668 = 667
entPhysicalContainedIn.669 = 668
entPhysicalContainedIn.681 = 300
entPhysicalContainedIn.695 = 300
entPhysicalContainedIn.696 = 695
entPhysicalContainedIn.697 = 696
entPhysicalContainedIn.699 = 696
entPhysicalContainedIn.700 = 696
entPhysicalContainedIn.701 = 696
entPhysicalContainedIn.702 = 696
entPhysicalContainedIn.703 = 696
entPhysicalContainedIn.709 = 300
entPhysicalContainedIn.710 = 709
entPhysicalContainedIn.711 = 710
entPhysicalContainedIn.713 = 710
entPhysicalContainedIn.714 = 710
entPhysicalContainedIn.715 = 710
entPhysicalContainedIn.716 = 710
entPhysicalContainedIn.717 = 710
entPhysicalContainedIn.723 = 300
entPhysicalContainedIn.724 = 723
entPhysicalContainedIn.725 = 724
entPhysicalContainedIn.727 = 724
entPhysicalContainedIn.728 = 724
entPhysicalContainedIn.729 = 724
entPhysicalContainedIn.730 = 724
entPhysicalContainedIn.731 = 724
entPhysicalContainedIn.737 = 300
entPhysicalContainedIn.738 = 737
entPhysicalContainedIn.739 = 738
entPhysicalContainedIn.741 = 738
entPhysicalContainedIn.742 = 738
entPhysicalContainedIn.743 = 738
entPhysicalContainedIn.744 = 738
entPhysicalContainedIn.745 = 738
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalParentRelPos]

CMD EXITCODE[0]
CMD RUNTIME[0.0873s]
STDOUT[
entPhysicalParentRelPos.1 = -1
entPhysicalParentRelPos.2 = 6
entPhysicalParentRelPos.3 = 0
entPhysicalParentRelPos.4 = 1
entPhysicalParentRelPos.5 = 11
entPhysicalParentRelPos.6 = 0
entPhysicalParentRelPos.7 = 0
entPhysicalParentRelPos.8 = 1
entPhysicalParentRelPos.9 = 2
entPhysicalParentRelPos.10 = 3
entPhysicalParentRelPos.11 = 4
entPhysicalParentRelPos.12 = 5
entPhysicalParentRelPos.25 = 12
entPhysicalParentRelPos.26 = 0
entPhysicalParentRelPos.27 = 0
entPhysicalParentRelPos.28 = 1
entPhysicalParentRelPos.29 = 2
entPhysicalParentRelPos.30 = 3
entPhysicalParentRelPos.31 = 4
entPhysicalParentRelPos.32 = 5
entPhysicalParentRelPos.45 = 13
entPhysicalParentRelPos.46 = 0
entPhysicalParentRelPos.47 = 0
entPhysicalParentRelPos.401 = 3
entPhysicalParentRelPos.415 = 4
entPhysicalParentRelPos.429 = 5
entPhysicalParentRelPos.443 = 6
entPhysicalParentRelPos.457 = 7
entPhysicalParentRelPos.471 = 8
entPhysicalParentRelPos.485 = 9
entPhysicalParentRelPos.499 = 10
entPhysicalParentRelPos.513 = 11
entPhysicalParentRelPos.527 = 12
entPhysicalParentRelPos.528 = 0
entPhysicalParentRelPos.529 = 0
entPhysicalParentRelPos.531 = 1
entPhysicalParentRelPos.532 = 2
entPhysicalParentRelPos.533 = 3
entPhysicalParentRelPos.534 = 4
entPhysicalParentRelPos.535 = 5
entPhysicalParentRelPos.541 = 13
entPhysicalParentRelPos.555 = 14
entPhysicalParentRelPos.569 = 15
entPhysicalParentRelPos.583 = 16
entPhysicalParentRelPos.597 = 17
entPhysicalParentRelPos.611 = 18
entPhysicalParentRelPos.625 = 19
entPhysicalParentRelPos.639 = 20
entPhysicalParentRelPos.653 = 21
entPhysicalParentRelPos.667 = 22
entPhysicalParentRelPos.668 = 0
entPhysicalParentRelPos.669 = 0
entPhysicalParentRelPos.681 = 23
entPhysicalParentRelPos.695 = 24
entPhysicalParentRelPos.696 = 0
entPhysicalParentRelPos.697 = 0
entPhysicalParentRelPos.699 = 1
entPhysicalParentRelPos.700 = 2
entPhysicalParentRelPos.701 = 3
entPhysicalParentRelPos.702 = 4
entPhysicalParentRelPos.703 = 5
entPhysicalParentRelPos.709 = 25
entPhysicalParentRelPos.710 = 0
entPhysicalParentRelPos.711 = 0
entPhysicalParentRelPos.713 = 1
entPhysicalParentRelPos.714 = 2
entPhysicalParentRelPos.715 = 3
entPhysicalParentRelPos.716 = 4
entPhysicalParentRelPos.717 = 5
entPhysicalParentRelPos.723 = 26
entPhysicalParentRelPos.724 = 0
entPhysicalParentRelPos.725 = 0
entPhysicalParentRelPos.727 = 1
entPhysicalParentRelPos.728 = 2
entPhysicalParentRelPos.729 = 3
entPhysicalParentRelPos.730 = 4
entPhysicalParentRelPos.731 = 5
entPhysicalParentRelPos.737 = 27
entPhysicalParentRelPos.738 = 0
entPhysicalParentRelPos.739 = 0
entPhysicalParentRelPos.741 = 1
entPhysicalParentRelPos.742 = 2
entPhysicalParentRelPos.743 = 3
entPhysicalParentRelPos.744 = 4
entPhysicalParentRelPos.745 = 5
]
SNMP STATUS[TRUE]
Discover status: boi-colo-pe-3, .1.3.6.1.4.1.9.9.117.1.1.2.1.2.6, cefcFRUPowerOperStatus.6, PowerOperType, ASR 920 250W DC Power Supply, 2, snmp, , powersupply

SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '41' AND `status_type` = 'PowerOperType' AND `status_index` = 'cefcFRUPowerOperStatus.6' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00042081s]

SQL[SELECT * FROM `status` WHERE `device_id` = '41' AND `status_type` = 'PowerOperType' AND `status_index` = 'cefcFRUPowerOperStatus.6' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00019288s]
.Discover status: boi-colo-pe-3, .1.3.6.1.4.1.9.9.117.1.1.2.1.2.26, cefcFRUPowerOperStatus.26, PowerOperType, ASR 920 250W DC Power Supply, 2, snmp, , powersupply