[observium@observium observium]$ ./discovery.php -d -m sensors -h boi-colo-pe-3 DEBUG! CMD[/usr/bin/svn info /opt/observium] CMD EXITCODE[0] CMD RUNTIME[0.016s] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: http://svn.observium.org/svn/observium/branches/stable Repository Root: http://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 8850 Node Kind: directory Schedule: normal Last Changed Author: adama Last Changed Rev: 8841 Last Changed Date: 2017-09-12 08:30:58 -0600 (Tue, 12 Sep 2017) ] SQL RUNTIME[0.00009799s] CMD[/usr/bin/snmpget --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0041s] STDOUT[ NET-SNMP version: 5.7.2 ] CMD[/usr/bin/rrdtool --version | head -n1] CMD EXITCODE[0] CMD RUNTIME[0.0048s] STDOUT[ RRDtool 1.6.0 Copyright by Tobias Oetiker ] CMD[/usr/bin/env apache2 -v | awk '/Server version:/ {print $3}'] CMD EXITCODE[0] CMD RUNTIME[0.0054s] STDOUT[ ] CMD[/usr/sbin/httpd -v | awk '/Server version:/ {print $3}'] CMD EXITCODE[0] CMD RUNTIME[0.0247s] STDOUT[ Apache/2.4.6 ] CMD[date "+%:z"] CMD EXITCODE[0] CMD RUNTIME[0.0013s] STDOUT[ -06:00 ] SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00028706s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00016093s] SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.00039482s] ##### Software versions ##### o OS Linux 3.10.0-514.16.1.el7.x86_64 [amd64] (CentOS 7) o Apache 2.4.6 o PHP 7.0.18 (OPcache: ENABLED) o Python 2.7.5 o MySQL 5.5.52-MariaDB (extension: mysqli 5.5.52-MariaDB) o SNMP NET-SNMP 5.7.2 o RRDtool 1.6.0 ##### Memory Limit ##### o PHP 512B ##### MySQL mode ##### o MySQL ##### Charset info ##### o PHP UTF-8 o MySQL utf8 ##### Timezones info ##### o Date Monday, 30-Oct-17 14:59:06 MDT o PHP -06:00 o MySQL -06:00 SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';] SQL RUNTIME[0.00036597s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] SQL RUNTIME[0.00008702s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver';] SQL RUNTIME[0.00008798s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date';] SQL RUNTIME[0.00008702s] There is a newer revision of Observium available! Version 17.10.8930 (30th October 2017) is 89 revisions ahead. ##### Starting discovery run at 2017-10-30 14:59:06 ##### SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'boi-colo-pe-3' AND `status` = '1' ORDER BY `last_discovered_timetaken` ASC] SQL RUNTIME[0.00034595s] CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUst -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'boi-colo-pe-3':'161' sysObjectID.0 sysUpTime.0] CMD EXITCODE[0] CMD RUNTIME[0.015s] STDOUT[ sysObjectID.0 = enterprises.9.1.2102 sysUpTime.0 = 3063161135 ] SNMP STATUS[TRUE] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '41'] SQL RUNTIME[0.00018311s] SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '41'] SQL RUNTIME[0.00011992s] CMD[/bin/ps -ww -o pid,ppid,uid,gid,tty,stat,time,lstart,args -p 9359] CMD EXITCODE[0] CMD RUNTIME[0.0122s] CMD EXITDELAY[10ms] STDOUT[ PID PPID UID GID TT STAT TIME STARTED COMMAND 9359 60451 1001 1001 pts/1 S+ 00:00:00 Mon Oct 30 14:59:06 2017 php ./discovery.php -d -m sensors -h boi-colo-pe-3 ] entSensorValueUpdateRate.379 = 60 entSensorValueUpdateRate.380 = 60 entSensorValueUpdateRate.381 = 60 entSensorValueUpdateRate.531 = 60 entSensorValueUpdateRate.532 = 60 entSensorValueUpdateRate.533 = 60 entSensorValueUpdateRate.534 = 60 entSensorValueUpdateRate.535 = 60 entSensorValueUpdateRate.699 = 60 entSensorValueUpdateRate.700 = 60 entSensorValueUpdateRate.701 = 60 entSensorValueUpdateRate.702 = 60 entSensorValueUpdateRate.703 = 60 entSensorValueUpdateRate.713 = 60 entSensorValueUpdateRate.714 = 60 entSensorValueUpdateRate.715 = 60 entSensorValueUpdateRate.716 = 60 entSensorValueUpdateRate.717 = 60 entSensorValueUpdateRate.727 = 60 entSensorValueUpdateRate.728 = 60 entSensorValueUpdateRate.729 = 60 entSensorValueUpdateRate.730 = 60 entSensorValueUpdateRate.731 = 60 entSensorValueUpdateRate.741 = 60 entSensorValueUpdateRate.742 = 60 entSensorValueUpdateRate.743 = 60 entSensorValueUpdateRate.744 = 60 entSensorValueUpdateRate.745 = 60 entSensorMeasuredEntity.7 = 6 entSensorMeasuredEntity.8 = 6 entSensorMeasuredEntity.9 = 6 entSensorMeasuredEntity.10 = 6 entSensorMeasuredEntity.11 = 6 entSensorMeasuredEntity.12 = 6 entSensorMeasuredEntity.27 = 26 entSensorMeasuredEntity.28 = 26 entSensorMeasuredEntity.29 = 26 entSensorMeasuredEntity.30 = 26 entSensorMeasuredEntity.31 = 26 entSensorMeasuredEntity.32 = 26 entSensorMeasuredEntity.47 = 46 entSensorMeasuredEntity.101 = 100 entSensorMeasuredEntity.102 = 100 entSensorMeasuredEntity.103 = 100 entSensorMeasuredEntity.104 = 100 entSensorMeasuredEntity.105 = 100 entSensorMeasuredEntity.106 = 100 entSensorMeasuredEntity.107 = 100 entSensorMeasuredEntity.108 = 100 entSensorMeasuredEntity.109 = 100 entSensorMeasuredEntity.110 = 100 entSensorMeasuredEntity.111 = 100 entSensorMeasuredEntity.112 = 100 entSensorMeasuredEntity.113 = 100 entSensorMeasuredEntity.114 = 100 entSensorMeasuredEntity.115 = 100 entSensorMeasuredEntity.116 = 100 entSensorMeasuredEntity.117 = 100 entSensorMeasuredEntity.118 = 100 entSensorMeasuredEntity.119 = 100 entSensorMeasuredEntity.120 = 100 entSensorMeasuredEntity.121 = 100 entSensorMeasuredEntity.122 = 100 entSensorMeasuredEntity.377 = 0 entSensorMeasuredEntity.378 = 0 entSensorMeasuredEntity.379 = 0 entSensorMeasuredEntity.380 = 0 entSensorMeasuredEntity.381 = 0 entSensorMeasuredEntity.531 = 0 entSensorMeasuredEntity.532 = 0 entSensorMeasuredEntity.533 = 0 entSensorMeasuredEntity.534 = 0 entSensorMeasuredEntity.535 = 0 entSensorMeasuredEntity.699 = 0 entSensorMeasuredEntity.700 = 0 entSensorMeasuredEntity.701 = 0 entSensorMeasuredEntity.702 = 0 entSensorMeasuredEntity.703 = 0 entSensorMeasuredEntity.713 = 0 entSensorMeasuredEntity.714 = 0 entSensorMeasuredEntity.715 = 0 entSensorMeasuredEntity.716 = 0 entSensorMeasuredEntity.717 = 0 entSensorMeasuredEntity.727 = 0 entSensorMeasuredEntity.728 = 0 entSensorMeasuredEntity.729 = 0 entSensorMeasuredEntity.730 = 0 entSensorMeasuredEntity.731 = 0 entSensorMeasuredEntity.741 = 0 entSensorMeasuredEntity.742 = 0 entSensorMeasuredEntity.743 = 0 entSensorMeasuredEntity.744 = 0 entSensorMeasuredEntity.745 = 0 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalDescr] CMD EXITCODE[0] CMD RUNTIME[0.0706s] STDOUT[ entPhysicalDescr.1 = Cisco ASR920 Series - 24GE Fiber and 4-10GE - Modular PSU entPhysicalDescr.2 = FIXED RSP Slot entPhysicalDescr.3 = FIXED IM Bay entPhysicalDescr.4 = FIXED IM Bay entPhysicalDescr.5 = Power Supply Bay entPhysicalDescr.6 = ASR 920 250W DC Power Supply entPhysicalDescr.7 = PEM Iout entPhysicalDescr.8 = PEM Vout entPhysicalDescr.9 = PEM Vin entPhysicalDescr.10 = PEM Pin entPhysicalDescr.11 = Temp: Temp 3 entPhysicalDescr.12 = Temp: Temp 2 entPhysicalDescr.25 = Power Supply Bay entPhysicalDescr.26 = ASR 920 250W DC Power Supply entPhysicalDescr.27 = PEM Iout entPhysicalDescr.28 = PEM Vout entPhysicalDescr.29 = PEM Vin entPhysicalDescr.30 = PEM Pin entPhysicalDescr.31 = Temp: Temp 3 entPhysicalDescr.32 = Temp: Temp 2 entPhysicalDescr.45 = Fan Tray Bay entPhysicalDescr.46 = ASR 920 Fan tray entPhysicalDescr.47 = Temp: FC PWM entPhysicalDescr.108 = VADM1: VH entPhysicalDescr.109 = VADM1: AUX1 entPhysicalDescr.110 = VADM1: AUX2 entPhysicalDescr.111 = Temp: CYLON entPhysicalDescr.112 = Temp: BOARD entPhysicalDescr.113 = Temp: Outlet entPhysicalDescr.114 = Temp: CPU entPhysicalDescr.115 = VADM2: VX1 entPhysicalDescr.116 = VADM2: VX2 entPhysicalDescr.117 = VADM2: VX3 entPhysicalDescr.118 = VADM2: VP1 entPhysicalDescr.119 = VADM2: VP2 entPhysicalDescr.120 = VADM2: VP3 entPhysicalDescr.121 = VADM2: VH entPhysicalDescr.122 = Temp: Inlet entPhysicalDescr.130 = CYLON entPhysicalDescr.131 = CPU 0 of module R0 entPhysicalDescr.132 = USB Port entPhysicalDescr.134 = USB Port entPhysicalDescr.136 = Network Management Ethernet entPhysicalDescr.300 = FIXED : 24-port Gig & 4-port Ten Gig SFP Ethernet Interface Module entPhysicalDescr.359 = subslot 0/0 transceiver container 0 entPhysicalDescr.373 = subslot 0/0 transceiver container 1 entPhysicalDescr.374 = GE LX entPhysicalDescr.375 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.377 = subslot 0/0 transceiver 1 Temperature Sensor entPhysicalDescr.378 = subslot 0/0 transceiver 1 Supply Voltage Sensor entPhysicalDescr.379 = subslot 0/0 transceiver 1 Bias Current Sensor entPhysicalDescr.380 = subslot 0/0 transceiver 1 Tx Power Sensor entPhysicalDescr.381 = subslot 0/0 transceiver 1 Rx Power Sensor entPhysicalDescr.387 = subslot 0/0 transceiver container 2 entPhysicalDescr.401 = subslot 0/0 transceiver container 3 entPhysicalDescr.415 = subslot 0/0 transceiver container 4 entPhysicalDescr.429 = subslot 0/0 transceiver container 5 entPhysicalDescr.443 = subslot 0/0 transceiver container 6 entPhysicalDescr.457 = subslot 0/0 transceiver container 7 entPhysicalDescr.471 = subslot 0/0 transceiver container 8 entPhysicalDescr.485 = subslot 0/0 transceiver container 9 entPhysicalDescr.499 = subslot 0/0 transceiver container 10 entPhysicalDescr.513 = subslot 0/0 transceiver container 11 entPhysicalDescr.527 = subslot 0/0 transceiver container 12 entPhysicalDescr.528 = GE LX entPhysicalDescr.529 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.531 = subslot 0/0 transceiver 12 Temperature Sensor entPhysicalDescr.532 = subslot 0/0 transceiver 12 Supply Voltage Sensor entPhysicalDescr.533 = subslot 0/0 transceiver 12 Bias Current Sensor entPhysicalDescr.534 = subslot 0/0 transceiver 12 Tx Power Sensor entPhysicalDescr.535 = subslot 0/0 transceiver 12 Rx Power Sensor entPhysicalDescr.541 = subslot 0/0 transceiver container 13 entPhysicalDescr.555 = subslot 0/0 transceiver container 14 entPhysicalDescr.569 = subslot 0/0 transceiver container 15 entPhysicalDescr.583 = subslot 0/0 transceiver container 16 entPhysicalDescr.597 = subslot 0/0 transceiver container 17 entPhysicalDescr.611 = subslot 0/0 transceiver container 18 entPhysicalDescr.625 = subslot 0/0 transceiver container 19 entPhysicalDescr.639 = subslot 0/0 transceiver container 20 entPhysicalDescr.653 = subslot 0/0 transceiver container 21 entPhysicalDescr.667 = subslot 0/0 transceiver container 22 entPhysicalDescr.668 = GE T entPhysicalDescr.669 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.681 = subslot 0/0 transceiver container 23 entPhysicalDescr.695 = subslot 0/0 transceiver container 24 entPhysicalDescr.696 = SFP+ 10GBASE-LR entPhysicalDescr.697 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.699 = subslot 0/0 transceiver 24 Temperature Sensor entPhysicalDescr.700 = subslot 0/0 transceiver 24 Supply Voltage Sensor entPhysicalDescr.701 = subslot 0/0 transceiver 24 Bias Current Sensor entPhysicalDescr.702 = subslot 0/0 transceiver 24 Tx Power Sensor entPhysicalDescr.703 = subslot 0/0 transceiver 24 Rx Power Sensor entPhysicalDescr.709 = subslot 0/0 transceiver container 25 entPhysicalDescr.710 = SFP+ 10GBASE-LR entPhysicalDescr.711 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.713 = subslot 0/0 transceiver 25 Temperature Sensor entPhysicalDescr.714 = subslot 0/0 transceiver 25 Supply Voltage Sensor entPhysicalDescr.715 = subslot 0/0 transceiver 25 Bias Current Sensor entPhysicalDescr.716 = subslot 0/0 transceiver 25 Tx Power Sensor entPhysicalDescr.717 = subslot 0/0 transceiver 25 Rx Power Sensor entPhysicalDescr.723 = subslot 0/0 transceiver container 26 entPhysicalDescr.724 = SFP+ 10GBASE-ER entPhysicalDescr.725 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.727 = subslot 0/0 transceiver 26 Temperature Sensor entPhysicalDescr.728 = subslot 0/0 transceiver 26 Supply Voltage Sensor entPhysicalDescr.729 = subslot 0/0 transceiver 26 Bias Current Sensor entPhysicalDescr.730 = subslot 0/0 transceiver 26 Tx Power Sensor entPhysicalDescr.731 = subslot 0/0 transceiver 26 Rx Power Sensor entPhysicalDescr.737 = subslot 0/0 transceiver container 27 entPhysicalDescr.738 = SFP+ 10GBASE-LR entPhysicalDescr.739 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.741 = subslot 0/0 transceiver 27 Temperature Sensor entPhysicalDescr.742 = subslot 0/0 transceiver 27 Supply Voltage Sensor entPhysicalDescr.743 = subslot 0/0 transceiver 27 Bias Current Sensor entPhysicalDescr.744 = subslot 0/0 transceiver 27 Tx Power Sensor entPhysicalDescr.745 = subslot 0/0 transceiver 27 Rx Power Sensor ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalName] CMD EXITCODE[0] CMD RUNTIME[0.0707s] STDOUT[ entPhysicalName.1 = Chassis entPhysicalName.2 = slot R0 entPhysicalName.3 = subslot 0/0 entPhysicalName.4 = subslot 0/1 entPhysicalName.5 = Power Supply Bay 0 entPhysicalName.6 = Power Supply Module 0 entPhysicalName.7 = PEM Iout P0/0 entPhysicalName.8 = PEM Vout P0/1 entPhysicalName.9 = PEM Vin P0/2 entPhysicalName.10 = PEM Pin P0/3 entPhysicalName.11 = Temp: Temp 3 P0/4 entPhysicalName.12 = Temp: Temp 2 P0/5 entPhysicalName.25 = Power Supply Bay 1 entPhysicalName.26 = Power Supply Module 1 entPhysicalName.27 = PEM Iout P1/0 entPhysicalName.28 = PEM Vout P1/1 entPhysicalName.29 = PEM Vin P1/2 entPhysicalName.30 = PEM Pin P1/3 entPhysicalName.31 = Temp: Temp 3 P1/4 entPhysicalName.32 = Temp: Temp 2 P1/5 entPhysicalName.45 = Fan Tray Bay 0 entPhysicalName.46 = Fan Tray entPhysicalName.47 = Temp: FC PWM P2/0 entPhysicalName.108 = VADM1: VH R0/7 entPhysicalName.109 = VADM1: AUX1 R0/8 entPhysicalName.110 = VADM1: AUX2 R0/9 entPhysicalName.111 = Temp: CYLON R0/10 entPhysicalName.112 = Temp: BOARD R0/11 entPhysicalName.113 = Temp: Outlet R0/12 entPhysicalName.114 = Temp: CPU R0/13 entPhysicalName.115 = VADM2: VX1 R0/14 entPhysicalName.116 = VADM2: VX2 R0/15 entPhysicalName.117 = VADM2: VX3 R0/16 entPhysicalName.118 = VADM2: VP1 R0/17 entPhysicalName.119 = VADM2: VP2 R0/18 entPhysicalName.120 = VADM2: VP3 R0/19 entPhysicalName.121 = VADM2: VH R0/20 entPhysicalName.122 = Temp: Inlet R0/21 entPhysicalName.130 = CYLON entPhysicalName.131 = cpu R0/0 entPhysicalName.132 = usb R0/0 entPhysicalName.134 = usb R0/1 entPhysicalName.136 = NME R0 entPhysicalName.300 = FIXED IM subslot 0/0 entPhysicalName.359 = subslot 0/0 transceiver container 0 entPhysicalName.373 = subslot 0/0 transceiver container 1 entPhysicalName.374 = subslot 0/0 transceiver 1 entPhysicalName.375 = GigabitEthernet0/0/1 entPhysicalName.377 = subslot 0/0 transceiver 1 Temperature Sensor entPhysicalName.378 = subslot 0/0 transceiver 1 Supply Voltage Sensor entPhysicalName.379 = subslot 0/0 transceiver 1 Bias Current Sensor entPhysicalName.380 = subslot 0/0 transceiver 1 Tx Power Sensor entPhysicalName.381 = subslot 0/0 transceiver 1 Rx Power Sensor entPhysicalName.387 = subslot 0/0 transceiver container 2 entPhysicalName.401 = subslot 0/0 transceiver container 3 entPhysicalName.415 = subslot 0/0 transceiver container 4 entPhysicalName.429 = subslot 0/0 transceiver container 5 entPhysicalName.443 = subslot 0/0 transceiver container 6 entPhysicalName.457 = subslot 0/0 transceiver container 7 entPhysicalName.471 = subslot 0/0 transceiver container 8 entPhysicalName.485 = subslot 0/0 transceiver container 9 entPhysicalName.499 = subslot 0/0 transceiver container 10 entPhysicalName.513 = subslot 0/0 transceiver container 11 entPhysicalName.527 = subslot 0/0 transceiver container 12 entPhysicalName.528 = subslot 0/0 transceiver 12 entPhysicalName.529 = GigabitEthernet0/0/12 entPhysicalName.531 = subslot 0/0 transceiver 12 Temperature Sensor entPhysicalName.532 = subslot 0/0 transceiver 12 Supply Voltage Sensor entPhysicalName.533 = subslot 0/0 transceiver 12 Bias Current Sensor entPhysicalName.534 = subslot 0/0 transceiver 12 Tx Power Sensor entPhysicalName.535 = subslot 0/0 transceiver 12 Rx Power Sensor entPhysicalName.541 = subslot 0/0 transceiver container 13 entPhysicalName.555 = subslot 0/0 transceiver container 14 entPhysicalName.569 = subslot 0/0 transceiver container 15 entPhysicalName.583 = subslot 0/0 transceiver container 16 entPhysicalName.597 = subslot 0/0 transceiver container 17 entPhysicalName.611 = subslot 0/0 transceiver container 18 entPhysicalName.625 = subslot 0/0 transceiver container 19 entPhysicalName.639 = subslot 0/0 transceiver container 20 entPhysicalName.653 = subslot 0/0 transceiver container 21 entPhysicalName.667 = subslot 0/0 transceiver container 22 entPhysicalName.668 = subslot 0/0 transceiver 22 entPhysicalName.669 = GigabitEthernet0/0/22 entPhysicalName.681 = subslot 0/0 transceiver container 23 entPhysicalName.695 = subslot 0/0 transceiver container 24 entPhysicalName.696 = subslot 0/0 transceiver 24 entPhysicalName.697 = TenGigabitEthernet0/0/24 entPhysicalName.699 = subslot 0/0 transceiver 24 Temperature Sensor entPhysicalName.700 = subslot 0/0 transceiver 24 Supply Voltage Sensor entPhysicalName.701 = subslot 0/0 transceiver 24 Bias Current Sensor entPhysicalName.702 = subslot 0/0 transceiver 24 Tx Power Sensor entPhysicalName.703 = subslot 0/0 transceiver 24 Rx Power Sensor entPhysicalName.709 = subslot 0/0 transceiver container 25 entPhysicalName.710 = subslot 0/0 transceiver 25 entPhysicalName.711 = TenGigabitEthernet0/0/25 entPhysicalName.713 = subslot 0/0 transceiver 25 Temperature Sensor entPhysicalName.714 = subslot 0/0 transceiver 25 Supply Voltage Sensor entPhysicalName.715 = subslot 0/0 transceiver 25 Bias Current Sensor entPhysicalName.716 = subslot 0/0 transceiver 25 Tx Power Sensor entPhysicalName.717 = subslot 0/0 transceiver 25 Rx Power Sensor entPhysicalName.723 = subslot 0/0 transceiver container 26 entPhysicalName.724 = subslot 0/0 transceiver 26 entPhysicalName.725 = TenGigabitEthernet0/0/26 entPhysicalName.727 = subslot 0/0 transceiver 26 Temperature Sensor entPhysicalName.728 = subslot 0/0 transceiver 26 Supply Voltage Sensor entPhysicalName.729 = subslot 0/0 transceiver 26 Bias Current Sensor entPhysicalName.730 = subslot 0/0 transceiver 26 Tx Power Sensor entPhysicalName.731 = subslot 0/0 transceiver 26 Rx Power Sensor entPhysicalName.737 = subslot 0/0 transceiver container 27 entPhysicalName.738 = subslot 0/0 transceiver 27 entPhysicalName.739 = TenGigabitEthernet0/0/27 entPhysicalName.741 = subslot 0/0 transceiver 27 Temperature Sensor entPhysicalName.742 = subslot 0/0 transceiver 27 Supply Voltage Sensor entPhysicalName.743 = subslot 0/0 transceiver 27 Bias Current Sensor entPhysicalName.744 = subslot 0/0 transceiver 27 Tx Power Sensor entPhysicalName.745 = subslot 0/0 transceiver 27 Rx Power Sensor ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalClass] CMD EXITCODE[0] CMD RUNTIME[0.0761s] STDOUT[ entPhysicalClass.1 = chassis entPhysicalClass.2 = container entPhysicalClass.3 = container entPhysicalClass.4 = container entPhysicalClass.5 = container entPhysicalClass.6 = powerSupply entPhysicalClass.7 = sensor entPhysicalClass.8 = sensor entPhysicalClass.9 = sensor entPhysicalClass.10 = sensor entPhysicalClass.11 = sensor entPhysicalClass.12 = sensor entPhysicalClass.25 = container entPhysicalClass.26 = powerSupply entPhysicalClass.27 = sensor entPhysicalClass.28 = sensor entPhysicalClass.29 = sensor entPhysicalClass.30 = sensor entPhysicalClass.31 = sensor entPhysicalClass.32 = sensor entPhysicalClass.45 = container entPhysicalClass.46 = fan entPhysicalClass.47 = sensor entPhysicalClass.108 = sensor entPhysicalClass.109 = sensor entPhysicalClass.110 = sensor entPhysicalClass.111 = sensor entPhysicalClass.112 = sensor entPhysicalClass.113 = sensor entPhysicalClass.114 = sensor entPhysicalClass.115 = sensor entPhysicalClass.116 = sensor entPhysicalClass.117 = sensor entPhysicalClass.118 = sensor entPhysicalClass.119 = sensor entPhysicalClass.120 = sensor entPhysicalClass.121 = sensor entPhysicalClass.122 = sensor entPhysicalClass.130 = cpu entPhysicalClass.131 = cpu entPhysicalClass.132 = container entPhysicalClass.134 = container entPhysicalClass.136 = port entPhysicalClass.300 = module entPhysicalClass.359 = container entPhysicalClass.373 = container entPhysicalClass.374 = module entPhysicalClass.375 = port entPhysicalClass.377 = sensor entPhysicalClass.378 = sensor entPhysicalClass.379 = sensor entPhysicalClass.380 = sensor entPhysicalClass.381 = sensor entPhysicalClass.387 = container entPhysicalClass.401 = container entPhysicalClass.415 = container entPhysicalClass.429 = container entPhysicalClass.443 = container entPhysicalClass.457 = container entPhysicalClass.471 = container entPhysicalClass.485 = container entPhysicalClass.499 = container entPhysicalClass.513 = container entPhysicalClass.527 = container entPhysicalClass.528 = module entPhysicalClass.529 = port entPhysicalClass.531 = sensor entPhysicalClass.532 = sensor entPhysicalClass.533 = sensor entPhysicalClass.534 = sensor entPhysicalClass.535 = sensor entPhysicalClass.541 = container entPhysicalClass.555 = container entPhysicalClass.569 = container entPhysicalClass.583 = container entPhysicalClass.597 = container entPhysicalClass.611 = container entPhysicalClass.625 = container entPhysicalClass.639 = container entPhysicalClass.653 = container entPhysicalClass.667 = container entPhysicalClass.668 = module entPhysicalClass.669 = port entPhysicalClass.681 = container entPhysicalClass.695 = container entPhysicalClass.696 = module entPhysicalClass.697 = port entPhysicalClass.699 = sensor entPhysicalClass.700 = sensor entPhysicalClass.701 = sensor entPhysicalClass.702 = sensor entPhysicalClass.703 = sensor entPhysicalClass.709 = container entPhysicalClass.710 = module entPhysicalClass.711 = port entPhysicalClass.713 = sensor entPhysicalClass.714 = sensor entPhysicalClass.715 = sensor entPhysicalClass.716 = sensor entPhysicalClass.717 = sensor entPhysicalClass.723 = container entPhysicalClass.724 = module entPhysicalClass.725 = port entPhysicalClass.727 = sensor entPhysicalClass.728 = sensor entPhysicalClass.729 = sensor entPhysicalClass.730 = sensor entPhysicalClass.731 = sensor entPhysicalClass.737 = container entPhysicalClass.738 = module entPhysicalClass.739 = port entPhysicalClass.741 = sensor entPhysicalClass.742 = sensor entPhysicalClass.743 = sensor entPhysicalClass.744 = sensor entPhysicalClass.745 = sensor ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalContainedIn] CMD EXITCODE[0] CMD RUNTIME[0.083s] STDOUT[ entPhysicalContainedIn.1 = 0 entPhysicalContainedIn.2 = 1 entPhysicalContainedIn.3 = 1 entPhysicalContainedIn.4 = 1 entPhysicalContainedIn.5 = 1 entPhysicalContainedIn.6 = 5 entPhysicalContainedIn.7 = 6 entPhysicalContainedIn.8 = 6 entPhysicalContainedIn.9 = 6 entPhysicalContainedIn.10 = 6 entPhysicalContainedIn.11 = 6 entPhysicalContainedIn.12 = 6 entPhysicalContainedIn.25 = 1 entPhysicalContainedIn.26 = 25 entPhysicalContainedIn.27 = 26 entPhysicalContainedIn.28 = 26 entPhysicalContainedIn.29 = 26 entPhysicalContainedIn.30 = 26 entPhysicalContainedIn.31 = 26 entPhysicalContainedIn.32 = 26 entPhysicalContainedIn.45 = 1 entPhysicalContainedIn.46 = 45 entPhysicalContainedIn.47 = 46 entPhysicalContainedIn.108 = 100 entPhysicalContainedIn.109 = 100 entPhysicalContainedIn.110 = 100 entPhysicalContainedIn.111 = 100 entPhysicalContainedIn.112 = 100 entPhysicalContainedIn.113 = 100 entPhysicalContainedIn.114 = 100 entPhysicalContainedIn.115 = 100 entPhysicalContainedIn.116 = 100 entPhysicalContainedIn.117 = 100 entPhysicalContainedIn.118 = 100 entPhysicalContainedIn.119 = 100 entPhysicalContainedIn.120 = 100 entPhysicalContainedIn.121 = 100 entPhysicalContainedIn.122 = 100 entPhysicalContainedIn.130 = 100 entPhysicalContainedIn.131 = 100 entPhysicalContainedIn.132 = 100 entPhysicalContainedIn.134 = 100 entPhysicalContainedIn.136 = 100 entPhysicalContainedIn.300 = 3 entPhysicalContainedIn.359 = 300 entPhysicalContainedIn.373 = 300 entPhysicalContainedIn.374 = 373 entPhysicalContainedIn.375 = 374 entPhysicalContainedIn.377 = 374 entPhysicalContainedIn.378 = 374 entPhysicalContainedIn.379 = 374 entPhysicalContainedIn.380 = 374 entPhysicalContainedIn.381 = 374 entPhysicalContainedIn.387 = 300 entPhysicalContainedIn.401 = 300 entPhysicalContainedIn.415 = 300 entPhysicalContainedIn.429 = 300 entPhysicalContainedIn.443 = 300 entPhysicalContainedIn.457 = 300 entPhysicalContainedIn.471 = 300 entPhysicalContainedIn.485 = 300 entPhysicalContainedIn.499 = 300 entPhysicalContainedIn.513 = 300 entPhysicalContainedIn.527 = 300 entPhysicalContainedIn.528 = 527 entPhysicalContainedIn.529 = 528 entPhysicalContainedIn.531 = 528 entPhysicalContainedIn.532 = 528 entPhysicalContainedIn.533 = 528 entPhysicalContainedIn.534 = 528 entPhysicalContainedIn.535 = 528 entPhysicalContainedIn.541 = 300 entPhysicalContainedIn.555 = 300 entPhysicalContainedIn.569 = 300 entPhysicalContainedIn.583 = 300 entPhysicalContainedIn.597 = 300 entPhysicalContainedIn.611 = 300 entPhysicalContainedIn.625 = 300 entPhysicalContainedIn.639 = 300 entPhysicalContainedIn.653 = 300 entPhysicalContainedIn.667 = 300 entPhysicalContainedIn.668 = 667 entPhysicalContainedIn.669 = 668 entPhysicalContainedIn.681 = 300 entPhysicalContainedIn.695 = 300 entPhysicalContainedIn.696 = 695 entPhysicalContainedIn.697 = 696 entPhysicalContainedIn.699 = 696 entPhysicalContainedIn.700 = 696 entPhysicalContainedIn.701 = 696 entPhysicalContainedIn.702 = 696 entPhysicalContainedIn.703 = 696 entPhysicalContainedIn.709 = 300 entPhysicalContainedIn.710 = 709 entPhysicalContainedIn.711 = 710 entPhysicalContainedIn.713 = 710 entPhysicalContainedIn.714 = 710 entPhysicalContainedIn.715 = 710 entPhysicalContainedIn.716 = 710 entPhysicalContainedIn.717 = 710 entPhysicalContainedIn.723 = 300 entPhysicalContainedIn.724 = 723 entPhysicalContainedIn.725 = 724 entPhysicalContainedIn.727 = 724 entPhysicalContainedIn.728 = 724 entPhysicalContainedIn.729 = 724 entPhysicalContainedIn.730 = 724 entPhysicalContainedIn.731 = 724 entPhysicalContainedIn.737 = 300 entPhysicalContainedIn.738 = 737 entPhysicalContainedIn.739 = 738 entPhysicalContainedIn.741 = 738 entPhysicalContainedIn.742 = 738 entPhysicalContainedIn.743 = 738 entPhysicalContainedIn.744 = 738 entPhysicalContainedIn.745 = 738 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalParentRelPos] CMD EXITCODE[0] CMD RUNTIME[0.0815s] STDOUT[ entPhysicalParentRelPos.1 = -1 entPhysicalParentRelPos.2 = 6 entPhysicalParentRelPos.3 = 0 entPhysicalParentRelPos.4 = 1 entPhysicalParentRelPos.5 = 11 entPhysicalParentRelPos.6 = 0 entPhysicalParentRelPos.7 = 0 entPhysicalParentRelPos.8 = 1 entPhysicalParentRelPos.9 = 2 entPhysicalParentRelPos.10 = 3 entPhysicalParentRelPos.11 = 4 entPhysicalParentRelPos.12 = 5 entPhysicalParentRelPos.25 = 12 entPhysicalParentRelPos.26 = 0 entPhysicalParentRelPos.27 = 0 entPhysicalParentRelPos.28 = 1 entPhysicalParentRelPos.29 = 2 entPhysicalParentRelPos.30 = 3 entPhysicalParentRelPos.31 = 4 entPhysicalParentRelPos.32 = 5 entPhysicalParentRelPos.45 = 13 entPhysicalParentRelPos.46 = 0 entPhysicalParentRelPos.47 = 0 entPhysicalParentRelPos.108 = 7 entPhysicalParentRelPos.109 = 8 entPhysicalParentRelPos.110 = 9 entPhysicalParentRelPos.111 = 10 entPhysicalParentRelPos.112 = 11 entPhysicalParentRelPos.113 = 12 entPhysicalParentRelPos.114 = 13 entPhysicalParentRelPos.115 = 14 entPhysicalParentRelPos.116 = 15 entPhysicalParentRelPos.117 = 16 entPhysicalParentRelPos.118 = 17 entPhysicalParentRelPos.119 = 18 entPhysicalParentRelPos.120 = 19 entPhysicalParentRelPos.121 = 20 entPhysicalParentRelPos.122 = 21 entPhysicalParentRelPos.130 = 1 entPhysicalParentRelPos.131 = 0 entPhysicalParentRelPos.132 = 0 entPhysicalParentRelPos.134 = 1 entPhysicalParentRelPos.136 = 2 entPhysicalParentRelPos.300 = 0 entPhysicalParentRelPos.359 = 0 entPhysicalParentRelPos.373 = 1 entPhysicalParentRelPos.374 = 0 entPhysicalParentRelPos.375 = 0 entPhysicalParentRelPos.377 = 1 entPhysicalParentRelPos.378 = 2 entPhysicalParentRelPos.379 = 3 entPhysicalParentRelPos.380 = 4 entPhysicalParentRelPos.381 = 5 entPhysicalParentRelPos.387 = 2 entPhysicalParentRelPos.401 = 3 entPhysicalParentRelPos.415 = 4 entPhysicalParentRelPos.429 = 5 entPhysicalParentRelPos.443 = 6 entPhysicalParentRelPos.457 = 7 entPhysicalParentRelPos.471 = 8 entPhysicalParentRelPos.485 = 9 entPhysicalParentRelPos.499 = 10 entPhysicalParentRelPos.513 = 11 entPhysicalParentRelPos.527 = 12 entPhysicalParentRelPos.528 = 0 entPhysicalParentRelPos.529 = 0 entPhysicalParentRelPos.531 = 1 entPhysicalParentRelPos.532 = 2 entPhysicalParentRelPos.533 = 3 entPhysicalParentRelPos.534 = 4 entPhysicalParentRelPos.535 = 5 entPhysicalParentRelPos.541 = 13 entPhysicalParentRelPos.555 = 14 entPhysicalParentRelPos.569 = 15 entPhysicalParentRelPos.583 = 16 entPhysicalParentRelPos.597 = 17 entPhysicalParentRelPos.611 = 18 entPhysicalParentRelPos.625 = 19 entPhysicalParentRelPos.639 = 20 entPhysicalParentRelPos.653 = 21 entPhysicalParentRelPos.667 = 22 entPhysicalParentRelPos.668 = 0 entPhysicalParentRelPos.669 = 0 entPhysicalParentRelPos.681 = 23 entPhysicalParentRelPos.695 = 24 entPhysicalParentRelPos.696 = 0 entPhysicalParentRelPos.697 = 0 entPhysicalParentRelPos.699 = 1 entPhysicalParentRelPos.700 = 2 entPhysicalParentRelPos.701 = 3 entPhysicalParentRelPos.702 = 4 entPhysicalParentRelPos.703 = 5 entPhysicalParentRelPos.709 = 25 entPhysicalParentRelPos.710 = 0 entPhysicalParentRelPos.711 = 0 entPhysicalParentRelPos.713 = 1 entPhysicalParentRelPos.714 = 2 entPhysicalParentRelPos.715 = 3 entPhysicalParentRelPos.716 = 4 entPhysicalParentRelPos.717 = 5 entPhysicalParentRelPos.723 = 26 entPhysicalParentRelPos.724 = 0 entPhysicalParentRelPos.725 = 0 entPhysicalParentRelPos.727 = 1 entPhysicalParentRelPos.728 = 2 entPhysicalParentRelPos.729 = 3 entPhysicalParentRelPos.730 = 4 entPhysicalParentRelPos.731 = 5 entPhysicalParentRelPos.737 = 27 entPhysicalParentRelPos.738 = 0 entPhysicalParentRelPos.739 = 0 entPhysicalParentRelPos.741 = 1 entPhysicalParentRelPos.742 = 2 entPhysicalParentRelPos.743 = 3 entPhysicalParentRelPos.744 = 4 entPhysicalParentRelPos.745 = 5 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'boi-colo-pe-3':'161' entAliasMappingIdentifier] CMD EXITCODE[0] CMD RUNTIME[0.0106s] STDOUT[ entAliasMappingIdentifier.136.0 = ifIndex.29 entAliasMappingIdentifier.375.0 = ifIndex.2 entAliasMappingIdentifier.529.0 = ifIndex.13 entAliasMappingIdentifier.669.0 = ifIndex.23 entAliasMappingIdentifier.697.0 = ifIndex.25 entAliasMappingIdentifier.711.0 = ifIndex.26 entAliasMappingIdentifier.725.0 = ifIndex.27 entAliasMappingIdentifier.739.0 = ifIndex.28 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entSensorThresholdSeverity] CMD EXITCODE[0] CMD RUNTIME[0.0522s] STDOUT[ entSensorThresholdSeverity.11.1 = minor entSensorThresholdSeverity.11.2 = major entSensorThresholdSeverity.11.3 = critical entSensorThresholdSeverity.11.4 = critical entSensorThresholdSeverity.12.1 = minor entSensorThresholdSeverity.12.2 = major entSensorThresholdSeverity.12.3 = critical entSensorThresholdSeverity.532.4 = critical entSensorThresholdSeverity.533.1 = critical entSensorThresholdSeverity.533.2 = minor entSensorThresholdSeverity.533.3 = minor entSensorThresholdSeverity.533.4 = critical entSensorThresholdSeverity.534.1 = critical entSensorThresholdSeverity.534.2 = minor entSensorThresholdSeverity.534.3 = minor entSensorThresholdSeverity.534.4 = critical entSensorThresholdSeverity.535.1 = critical entSensorThresholdSeverity.535.2 = minor entSensorThresholdSeverity.535.3 = minor entSensorThresholdSeverity.535.4 = critical entSensorThresholdSeverity.699.1 = critical entSensorThresholdSeverity.699.2 = minor entSensorThresholdSeverity.699.3 = minor entSensorThresholdSeverity.699.4 = critical entSensorThresholdSeverity.700.1 = critical entSensorThresholdSeverity.700.2 = minor entSensorThresholdSeverity.700.3 = minor entSensorThresholdSeverity.700.4 = critical entSensorThresholdSeverity.701.1 = critical entSensorThresholdSeverity.701.2 = minor entSensorThresholdSeverity.701.3 = minor entSensorThresholdSeverity.701.4 = critical entSensorThresholdSeverity.702.1 = critical entSensorThresholdSeverity.702.2 = minor entSensorThresholdSeverity.702.3 = minor entSensorThresholdSeverity.702.4 = critical entSensorThresholdSeverity.703.1 = critical entSensorThresholdSeverity.703.2 = minor entSensorThresholdSeverity.703.3 = minor entSensorThresholdSeverity.703.4 = critical entSensorThresholdSeverity.713.1 = critical entSensorThresholdSeverity.713.2 = minor entSensorThresholdSeverity.713.3 = minor entSensorThresholdSeverity.713.4 = critical entSensorThresholdSeverity.714.1 = critical entSensorThresholdSeverity.714.2 = minor entSensorThresholdSeverity.714.3 = minor entSensorThresholdSeverity.714.4 = critical entSensorThresholdSeverity.715.1 = critical entSensorThresholdSeverity.715.2 = minor entSensorThresholdSeverity.715.3 = minor entSensorThresholdSeverity.715.4 = critical entSensorThresholdSeverity.716.1 = critical entSensorThresholdSeverity.716.2 = minor entSensorThresholdSeverity.716.3 = minor entSensorThresholdSeverity.716.4 = critical entSensorThresholdSeverity.717.1 = critical entSensorThresholdSeverity.717.2 = minor entSensorThresholdSeverity.717.3 = minor entSensorThresholdSeverity.717.4 = critical entSensorThresholdSeverity.727.1 = critical entSensorThresholdSeverity.727.2 = minor entSensorThresholdSeverity.727.3 = minor entSensorThresholdSeverity.727.4 = critical entSensorThresholdSeverity.728.1 = critical entSensorThresholdSeverity.728.2 = minor entSensorThresholdSeverity.728.3 = minor entSensorThresholdSeverity.728.4 = critical entSensorThresholdSeverity.729.1 = critical entSensorThresholdSeverity.729.2 = minor entSensorThresholdSeverity.729.3 = minor entSensorThresholdSeverity.729.4 = critical entSensorThresholdSeverity.730.1 = critical entSensorThresholdSeverity.730.2 = minor entSensorThresholdSeverity.730.3 = minor entSensorThresholdSeverity.730.4 = critical entSensorThresholdSeverity.731.1 = critical entSensorThresholdSeverity.731.2 = minor entSensorThresholdSeverity.731.3 = minor entSensorThresholdSeverity.731.4 = critical entSensorThresholdSeverity.741.1 = critical entSensorThresholdSeverity.741.2 = minor entSensorThresholdSeverity.741.3 = minor entSensorThresholdSeverity.741.4 = critical entSensorThresholdSeverity.742.1 = critical entSensorThresholdSeverity.742.2 = minor entSensorThresholdSeverity.742.3 = minor entSensorThresholdSeverity.742.4 = critical entSensorThresholdSeverity.743.1 = critical entSensorThresholdSeverity.743.2 = minor entSensorThresholdSeverity.743.3 = minor entSensorThresholdSeverity.743.4 = critical entSensorThresholdSeverity.744.1 = critical entSensorThresholdSeverity.744.2 = minor entSensorThresholdSeverity.744.3 = minor entSensorThresholdSeverity.744.4 = critical entSensorThresholdSeverity.745.1 = critical entSensorThresholdSeverity.745.2 = minor entSensorThresholdSeverity.745.3 = minor entSensorThresholdSeverity.745.4 = critical ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entSensorThresholdRelation] CMD EXITCODE[0] CMD RUNTIME[0.0534s] STDOUT[ entSensorThresholdRelation.11.1 = greaterOrEqual entSensorThresholdRelation.11.2 = greaterOrEqual entSensorThresholdRelation.11.3 = greaterOrEqual entSensorThresholdRelation.11.4 = greaterOrEqual entSensorThresholdRelation.12.1 = greaterOrEqual entSensorThresholdRelation.12.2 = greaterOrEqual entSensorThresholdRelation.12.3 = greaterOrEqual entSensorThresholdRelation.12.4 = greaterOrEqual entSensorThresholdRelation.31.1 = greaterOrEqual entSensorThresholdRelation.31.2 = greaterOrEqual entSensorThresholdRelation.31.3 = greaterOrEqual entSensorThresholdRelation.31.4 = greaterOrEqual entSensorThresholdRelation.32.1 = greaterOrEqual entSensorThresholdRelation.32.2 = greaterOrEqual entSensorThresholdRelation.32.3 = greaterOrEqual entSensorThresholdRelation.32.4 = greaterOrEqual entSensorThresholdRelation.111.1 = greaterOrEqual entSensorThresholdRelation.111.2 = greaterOrEqual entSensorThresholdRelation.111.3 = greaterOrEqual entSensorThresholdRelation.111.4 = greaterOrEqual entSensorThresholdRelation.112.1 = greaterOrEqual entSensorThresholdRelation.112.2 = greaterOrEqual entSensorThresholdRelation.112.3 = greaterOrEqual entSensorThresholdRelation.532.4 = lessOrEqual entSensorThresholdRelation.533.1 = greaterOrEqual entSensorThresholdRelation.533.2 = greaterOrEqual entSensorThresholdRelation.533.3 = lessOrEqual entSensorThresholdRelation.533.4 = lessOrEqual entSensorThresholdRelation.534.1 = greaterOrEqual entSensorThresholdRelation.534.2 = greaterOrEqual entSensorThresholdRelation.534.3 = lessOrEqual entSensorThresholdRelation.534.4 = lessOrEqual entSensorThresholdRelation.535.1 = greaterOrEqual entSensorThresholdRelation.535.2 = greaterOrEqual entSensorThresholdRelation.535.3 = lessOrEqual entSensorThresholdRelation.535.4 = lessOrEqual entSensorThresholdRelation.699.1 = greaterOrEqual entSensorThresholdRelation.699.2 = greaterOrEqual entSensorThresholdRelation.699.3 = lessOrEqual entSensorThresholdRelation.699.4 = lessOrEqual entSensorThresholdRelation.700.1 = greaterOrEqual entSensorThresholdRelation.700.2 = greaterOrEqual entSensorThresholdRelation.700.3 = lessOrEqual entSensorThresholdRelation.700.4 = lessOrEqual entSensorThresholdRelation.701.1 = greaterOrEqual entSensorThresholdRelation.701.2 = greaterOrEqual entSensorThresholdRelation.701.3 = lessOrEqual entSensorThresholdRelation.701.4 = lessOrEqual entSensorThresholdRelation.702.1 = greaterOrEqual entSensorThresholdRelation.702.2 = greaterOrEqual entSensorThresholdRelation.702.3 = lessOrEqual entSensorThresholdRelation.702.4 = lessOrEqual entSensorThresholdRelation.703.1 = greaterOrEqual entSensorThresholdRelation.703.2 = greaterOrEqual entSensorThresholdRelation.703.3 = lessOrEqual entSensorThresholdRelation.703.4 = lessOrEqual entSensorThresholdRelation.713.1 = greaterOrEqual entSensorThresholdRelation.713.2 = greaterOrEqual entSensorThresholdRelation.713.3 = lessOrEqual entSensorThresholdRelation.713.4 = lessOrEqual entSensorThresholdRelation.714.1 = greaterOrEqual entSensorThresholdRelation.714.2 = greaterOrEqual entSensorThresholdRelation.714.3 = lessOrEqual entSensorThresholdRelation.714.4 = lessOrEqual entSensorThresholdRelation.715.1 = greaterOrEqual entSensorThresholdRelation.715.2 = greaterOrEqual entSensorThresholdRelation.715.3 = lessOrEqual entSensorThresholdRelation.715.4 = lessOrEqual entSensorThresholdRelation.716.1 = greaterOrEqual entSensorThresholdRelation.716.2 = greaterOrEqual entSensorThresholdRelation.716.3 = lessOrEqual entSensorThresholdRelation.716.4 = lessOrEqual entSensorThresholdRelation.717.1 = greaterOrEqual entSensorThresholdRelation.717.2 = greaterOrEqual entSensorThresholdRelation.717.3 = lessOrEqual entSensorThresholdRelation.717.4 = lessOrEqual entSensorThresholdRelation.727.1 = greaterOrEqual entSensorThresholdRelation.727.2 = greaterOrEqual entSensorThresholdRelation.727.3 = lessOrEqual entSensorThresholdRelation.727.4 = lessOrEqual entSensorThresholdRelation.728.1 = greaterOrEqual entSensorThresholdRelation.728.2 = greaterOrEqual entSensorThresholdRelation.728.3 = lessOrEqual entSensorThresholdRelation.728.4 = lessOrEqual entSensorThresholdRelation.729.1 = greaterOrEqual entSensorThresholdRelation.729.2 = greaterOrEqual entSensorThresholdRelation.729.3 = lessOrEqual entSensorThresholdRelation.729.4 = lessOrEqual entSensorThresholdRelation.730.1 = greaterOrEqual entSensorThresholdRelation.730.2 = greaterOrEqual entSensorThresholdRelation.730.3 = lessOrEqual entSensorThresholdRelation.730.4 = lessOrEqual entSensorThresholdRelation.731.1 = greaterOrEqual entSensorThresholdRelation.731.2 = greaterOrEqual entSensorThresholdRelation.731.3 = lessOrEqual entSensorThresholdRelation.731.4 = lessOrEqual entSensorThresholdRelation.741.1 = greaterOrEqual entSensorThresholdRelation.741.2 = greaterOrEqual entSensorThresholdRelation.741.3 = lessOrEqual entSensorThresholdRelation.741.4 = lessOrEqual entSensorThresholdRelation.742.1 = greaterOrEqual entSensorThresholdRelation.742.2 = greaterOrEqual entSensorThresholdRelation.742.3 = lessOrEqual entSensorThresholdRelation.742.4 = lessOrEqual entSensorThresholdRelation.743.1 = greaterOrEqual entSensorThresholdRelation.743.2 = greaterOrEqual entSensorThresholdRelation.743.3 = lessOrEqual entSensorThresholdRelation.743.4 = lessOrEqual entSensorThresholdRelation.744.1 = greaterOrEqual entSensorThresholdRelation.744.2 = greaterOrEqual entSensorThresholdRelation.744.3 = lessOrEqual entSensorThresholdRelation.744.4 = lessOrEqual entSensorThresholdRelation.745.1 = greaterOrEqual entSensorThresholdRelation.745.2 = greaterOrEqual entSensorThresholdRelation.745.3 = lessOrEqual entSensorThresholdRelation.745.4 = lessOrEqual ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entSensorThresholdValue] CMD EXITCODE[0] CMD RUNTIME[0.0604s] STDOUT[ entSensorThresholdValue.11.1 = 90 entSensorThresholdValue.11.2 = 95 entSensorThresholdValue.11.3 = 100 entSensorThresholdValue.11.4 = 105 entSensorThresholdValue.12.1 = 100 entSensorThresholdValue.12.2 = 105 entSensorThresholdValue.12.3 = 110 entSensorThresholdValue.12.4 = 115 entSensorThresholdValue.31.1 = 90 entSensorThresholdValue.31.2 = 95 entSensorThresholdValue.31.3 = 100 entSensorThresholdValue.31.4 = 105 entSensorThresholdValue.32.1 = 100 entSensorThresholdValue.32.2 = 105 entSensorThresholdValue.32.3 = 110 entSensorThresholdValue.32.4 = 115 entSensorThresholdValue.111.1 = 100 entSensorThresholdValue.111.2 = 105 entSensorThresholdValue.111.3 = 110 entSensorThresholdValue.111.4 = 112 entSensorThresholdValue.112.1 = 85 entSensorThresholdValue.112.2 = 90 entSensorThresholdValue.112.3 = 93 entSensorThresholdValue.716.4 = -80 entSensorThresholdValue.717.1 = 0 entSensorThresholdValue.717.2 = -10 entSensorThresholdValue.717.3 = -144 entSensorThresholdValue.717.4 = -154 entSensorThresholdValue.727.1 = 100000 entSensorThresholdValue.727.2 = 95000 entSensorThresholdValue.727.3 = -5000 entSensorThresholdValue.727.4 = -10000 entSensorThresholdValue.728.1 = 38000 entSensorThresholdValue.728.2 = 36000 entSensorThresholdValue.728.3 = 30000 entSensorThresholdValue.728.4 = 28000 entSensorThresholdValue.729.1 = 100000 entSensorThresholdValue.729.2 = 90000 entSensorThresholdValue.729.3 = 9996 entSensorThresholdValue.729.4 = 0 entSensorThresholdValue.730.1 = 50 entSensorThresholdValue.730.2 = 40 entSensorThresholdValue.730.3 = -20 entSensorThresholdValue.730.4 = -30 entSensorThresholdValue.731.1 = -20 entSensorThresholdValue.731.2 = -30 entSensorThresholdValue.731.3 = -160 entSensorThresholdValue.731.4 = -180 entSensorThresholdValue.741.1 = 75000 entSensorThresholdValue.741.2 = 70000 entSensorThresholdValue.741.3 = 0 entSensorThresholdValue.741.4 = -5000 entSensorThresholdValue.742.1 = 35000 entSensorThresholdValue.742.2 = 34800 entSensorThresholdValue.742.3 = 31000 entSensorThresholdValue.742.4 = 30800 entSensorThresholdValue.743.1 = 90000 entSensorThresholdValue.743.2 = 80000 entSensorThresholdValue.743.3 = 4000 entSensorThresholdValue.743.4 = 2000 entSensorThresholdValue.744.1 = 0 entSensorThresholdValue.744.2 = -10 entSensorThresholdValue.744.3 = -60 entSensorThresholdValue.744.4 = -80 entSensorThresholdValue.745.1 = 0 entSensorThresholdValue.745.2 = -10 entSensorThresholdValue.745.3 = -144 entSensorThresholdValue.745.4 = -154 ] SNMP STATUS[TRUE] Discover sensor: current, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7, 7, cisco-entity-sensor, ASR 920 250W DC Power Supply - PEM Iout - PEM Iout P0/0, SCALE: 1, LIMITS: (, , , ), CURRENT: 3, snmp, 7, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '7'] SQL RUNTIME[0.00042510s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '7'] SQL RUNTIME[0.00040078s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2508' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00013804s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.8, 8, cisco-entity-sensor, ASR 920 250W DC Power Supply - PEM Vout - PEM Vout P0/1, SCALE: 1, LIMITS: (, , , ), CURRENT: 13, snmp, 8, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '8'] SQL RUNTIME[0.00026894s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '8'] SQL RUNTIME[0.00031710s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2509' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00011897s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.9, 9, cisco-entity-sensor, ASR 920 250W DC Power Supply - PEM Vin - PEM Vin P0/2, SCALE: 1, LIMITS: (, , , ), CURRENT: 54, snmp, 9, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '9'] SQL RUNTIME[0.00026107s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '9'] SQL RUNTIME[0.00031996s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2510' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012803s] .Discover sensor: power, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.10, 10, cisco-entity-sensor, ASR 920 250W DC Power Supply - PEM Pin - PEM Pin P0/3, SCALE: 1, LIMITS: (, , , ), CURRENT: 43, snmp, 10, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'power' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '10'] SQL RUNTIME[0.00051403s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'power' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '10'] SQL RUNTIME[0.00051498s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2511' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00015497s] .Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.11, 11, cisco-entity-sensor, ASR 920 250W DC Power Supply - Temp 3 - Temp 3 P0/4, SCALE: 1, LIMITS: (, , 90, 95), CURRENT: 34, snmp, 11, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '11'] SQL RUNTIME[0.00030708s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '11'] SQL RUNTIME[0.00031805s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2512' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012612s] .Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.12, 12, cisco-entity-sensor, ASR 920 250W DC Power Supply - Temp 2 - Temp 2 P0/5, SCALE: 1, LIMITS: (, , 100, 105), CURRENT: 31, snmp, 12, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '12'] SQL RUNTIME[0.00026488s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '12'] SQL RUNTIME[0.00034308s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2513' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00011802s] .Discover sensor: current, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.27, 27, cisco-entity-sensor, ASR 920 250W DC Power Supply - PEM Iout - PEM Iout P1/0, SCALE: 1, LIMITS: (, , , ), CURRENT: 3, snmp, 27, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '27'] SQL RUNTIME[0.00035286s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '27'] SQL RUNTIME[0.00039601s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2514' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00013494s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.28, 28, cisco-entity-sensor, ASR 920 250W DC Power Supply - PEM Vout - PEM Vout P1/1, SCALE: 1, LIMITS: (, , , ), CURRENT: 13, snmp, 28, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '28'] SQL RUNTIME[0.00027180s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '28'] SQL RUNTIME[0.00035906s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2515' AND `attrib_type` = 'sensor_addition'] 101'] SQL RUNTIME[0.00031018s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2521' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00011516s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.102, 102, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VX2 - VADM1: VX2 R0/1, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 1.048, snmp, 102, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '102'] SQL RUNTIME[0.00025702s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '102'] SQL RUNTIME[0.00032997s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2522' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00011420s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.103, 103, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VX3 - VADM1: VX3 R0/2, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 0.996, snmp, 103, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '103'] SQL RUNTIME[0.00026011s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '103'] SQL RUNTIME[0.00033307s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2523' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00014782s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.104, 104, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VP1 - VADM1: VP1 R0/3, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 3.294, snmp, 104, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '104'] SQL RUNTIME[0.00025296s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '104'] SQL RUNTIME[0.00032997s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2524' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00025415s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.105, 105, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VP2 - VADM1: VP2 R0/4, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 1.796, snmp, 105, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '105'] SQL RUNTIME[0.00025511s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '105'] SQL RUNTIME[0.00033593s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2525' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00016618s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.106, 106, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VP3 - VADM1: VP3 R0/5, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 1.199, snmp, 106, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '106'] SQL RUNTIME[0.00024915s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '106'] SQL RUNTIME[0.00033998s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2526' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00011897s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.107, 107, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VP4 - VADM1: VP4 R0/6, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 1.771, snmp, 107, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '107'] SQL RUNTIME[0.00028706s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '107'] SQL RUNTIME[0.00032020s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2527' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012684s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.108, 108, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: VH - VADM1: VH R0/7, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 12.495, snmp, 108, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '108'] SQL RUNTIME[0.00025082s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '108'] SQL RUNTIME[0.00031996s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2528' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00011587s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.109, 109, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: AUX1 - VADM1: AUX1 R0/8, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 4.971, snmp, 109, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '109'] SQL RUNTIME[0.00025201s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '109'] SQL RUNTIME[0.00032020s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2529' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00011706s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.110, 110, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM1: AUX2 - VADM1: AUX2 R0/9, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 6.93, snmp, 110, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '110'] SQL RUNTIME[0.00026107s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '110'] SQL RUNTIME[0.00032806s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2530' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012398s] .Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.111, 111, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - CYLON - CYLON R0/10, SCALE: 1, LIMITS: (, , 100, 105), CURRENT: 84, snmp, 111, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '111'] SQL RUNTIME[0.00026393s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '111'] SQL RUNTIME[0.00030708s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2531' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00015306s] .Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.112, 112, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - BOARD - BOARD R0/11, SCALE: 1, LIMITS: (, , 85, 90), CURRENT: 47, snmp, 112, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '112'] SQL RUNTIME[0.00025606s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '112'] SQL RUNTIME[0.00030613s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2532' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00014615s] .Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.113, 113, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - Outlet - Outlet R0/12, SCALE: 1, LIMITS: (, , 80, 85), CURRENT: 43, snmp, 113, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` SQL RUNTIME[0.00012589s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.117, 117, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM2: VX3 - VADM2: VX3 R0/16, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 0.753, snmp, 117, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '117'] SQL RUNTIME[0.00026107s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '117'] SQL RUNTIME[0.00035000s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2537' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012589s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.118, 118, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM2: VP1 - VADM2: VP1 R0/17, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 2.496, snmp, 118, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '118'] SQL RUNTIME[0.00026011s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '118'] SQL RUNTIME[0.00035310s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2538' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00013399s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.119, 119, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM2: VP2 - VADM2: VP2 R0/18, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 1.497, snmp, 119, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '119'] SQL RUNTIME[0.00026083s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '119'] SQL RUNTIME[0.00034285s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2539' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00013685s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.120, 120, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM2: VP3 - VADM2: VP3 R0/19, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 1.495, snmp, 120, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '120'] SQL RUNTIME[0.00026011s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '120'] SQL RUNTIME[0.00033593s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2540' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00013399s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.121, 121, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - VADM2: VH - VADM2: VH R0/20, SCALE: 0.001, LIMITS: (, , , ), CURRENT: 12.485, snmp, 121, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '121'] SQL RUNTIME[0.00025201s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '121'] SQL RUNTIME[0.00032091s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2541' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012493s] .Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.122, 122, cisco-entity-sensor, ASR 920 Route Switch Processor, Base Scale, 64Gbps,FIXED: 24GE Fiber and 4-10GE - Modular PSU and FAN - Inlet - Inlet R0/21, SCALE: 1, LIMITS: (, , 75, 77), CURRENT: 36, snmp, 122, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '122'] SQL RUNTIME[0.00028896s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '122'] SQL RUNTIME[0.00032592s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2542' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00011706s] .Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.377, 377, cisco-entity-sensor, subslot 0/0 transceiver 1 Temperature, SCALE: 0.001, LIMITS: (, 0, 75, ), CURRENT: 29.375, snmp, 377, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '377'] SQL RUNTIME[0.00027990s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '377'] SQL RUNTIME[0.00031519s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '41404' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00011706s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.378, 378, cisco-entity-sensor, subslot 0/0 transceiver 1 Supply Voltage, SCALE: 0.0001, LIMITS: (, 3.15, 3.47, ), CURRENT: 3.3187, snmp, 378, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '378'] SQL RUNTIME[0.00029302s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '378'] SQL RUNTIME[0.00033998s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '41405' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012398s] .Discover sensor: current, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.379, 379, cisco-entity-sensor, subslot 0/0 transceiver 1 Bias Current, SCALE: 1.0E-6, LIMITS: (, 0.004, 0.08, ), CURRENT: 0.01898, snmp, 379, Skipped by regexp: /.*subslot\ 0\/[0-9]\ transceiver\ [0-9][0-9]?\ Bias Current/, subslot 0/0 transceiver 1 Bias Current Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.380, 380, cisco-entity-sensor, subslot 0/0 transceiver 1 Tx Power, SCALE: 0.1, LIMITS: (, -9, -3, ), CURRENT: -5.9, snmp, 380, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '380'] SQL RUNTIME[0.00026989s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '380'] SQL RUNTIME[0.00030708s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '41406' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012612s] .Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.381, 381, cisco-entity-sensor, subslot 0/0 transceiver 1 Rx Power, SCALE: 0.1, LIMITS: (, -20, -3, ), CURRENT: -4.6, snmp, 381, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '381'] SQL RUNTIME[0.00028300s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '381'] SQL RUNTIME[0.00032115s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '41407' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012612s] .Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.531, 531, cisco-entity-sensor, subslot 0/0 transceiver 12 Temperature, SCALE: 0.001, LIMITS: (, 0, 75, ), CURRENT: 28.648, snmp, 531, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '531'] SQL RUNTIME[0.00026298s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '531'] SQL RUNTIME[0.00032902s] LIMITS: (, -20, -3, ), CURRENT: -9.2, snmp, 535, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '535'] SQL RUNTIME[0.00024581s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '535'] SQL RUNTIME[0.00030494s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28001' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00014615s] .Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.699, 699, cisco-entity-sensor, subslot 0/0 transceiver 24 Temperature, SCALE: 0.001, LIMITS: (, 0, 70, ), CURRENT: 38.515, snmp, 699, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '699'] SQL RUNTIME[0.00026608s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '699'] SQL RUNTIME[0.00031400s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2548' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00014806s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.700, 700, cisco-entity-sensor, subslot 0/0 transceiver 24 Supply Voltage, SCALE: 0.0001, LIMITS: (, 3.1, 3.48, ), CURRENT: 3.2854, snmp, 700, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '700'] SQL RUNTIME[0.00027108s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '700'] SQL RUNTIME[0.00031996s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2549' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00015092s] .Discover sensor: current, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.701, 701, cisco-entity-sensor, subslot 0/0 transceiver 24 Bias Current, SCALE: 1.0E-6, LIMITS: (, 0.004, 0.08, ), CURRENT: 0.040808, snmp, 701, Skipped by regexp: /.*subslot\ 0\/[0-9]\ transceiver\ [0-9][0-9]?\ Bias Current/, subslot 0/0 transceiver 24 Bias Current Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.702, 702, cisco-entity-sensor, subslot 0/0 transceiver 24 Tx Power, SCALE: 0.1, LIMITS: (, -6, -1, ), CURRENT: -3.1, snmp, 702, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '702'] SQL RUNTIME[0.00026894s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '702'] SQL RUNTIME[0.00031209s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2551' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00011611s] .Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.703, 703, cisco-entity-sensor, subslot 0/0 transceiver 24 Rx Power, SCALE: 0.1, LIMITS: (, -14.4, -1, ), CURRENT: -2.2, snmp, 703, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '703'] SQL RUNTIME[0.00025702s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '703'] SQL RUNTIME[0.00031805s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2552' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012708s] .Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.713, 713, cisco-entity-sensor, subslot 0/0 transceiver 25 Temperature, SCALE: 0.001, LIMITS: (, 0, 70, ), CURRENT: 37.835, snmp, 713, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '713'] SQL RUNTIME[0.00026703s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '713'] SQL RUNTIME[0.00034213s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2553' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012612s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.714, 714, cisco-entity-sensor, subslot 0/0 transceiver 25 Supply Voltage, SCALE: 0.0001, LIMITS: (, 3.1, 3.48, ), CURRENT: 3.276, snmp, 714, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '714'] SQL RUNTIME[0.00027490s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '714'] SQL RUNTIME[0.00034904s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2554' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012517s] .Discover sensor: current, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.715, 715, cisco-entity-sensor, subslot 0/0 transceiver 25 Bias Current, SCALE: 1.0E-6, LIMITS: (, 0.004, 0.08, ), CURRENT: 0.039808, snmp, 715, Skipped by regexp: /.*subslot\ 0\/[0-9]\ transceiver\ [0-9][0-9]?\ Bias Current/, subslot 0/0 transceiver 25 Bias Current Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.716, 716, cisco-entity-sensor, subslot 0/0 transceiver 25 Tx Power, SCALE: 0.1, LIMITS: (, -6, -1, ), CURRENT: -2.8, snmp, 716, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '716'] SQL RUNTIME[0.00024009s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '716'] SQL RUNTIME[0.00031304s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2556' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012398s] .Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.717, 717, cisco-entity-sensor, subslot 0/0 transceiver 25 Rx Power, SCALE: 0.1, LIMITS: (, -14.4, -1, ), CURRENT: -2.4, snmp, 717, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '717'] SQL RUNTIME[0.00024509s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '717'] SQL RUNTIME[0.00033498s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2557' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012493s] .Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.727, 727, cisco-entity-sensor, subslot 0/0 transceiver 26 Temperature, SCALE: 0.001, LIMITS: (, -5, 95, ), CURRENT: 45.554, snmp, 727, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '727'] SQL RUNTIME[0.00025320s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '727'] SQL RUNTIME[0.00035000s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2558' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00013614s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.728, 728, cisco-entity-sensor, subslot 0/0 transceiver 26 Supply Voltage, SCALE: 0.0001, LIMITS: (, 3, 3.6, ), CURRENT: 3.3531, snmp, 728, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '728'] SQL RUNTIME[0.00025702s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '728'] SQL RUNTIME[0.00034809s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2559' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00013399s] WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '730'] SQL RUNTIME[0.00117683s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '730'] SQL RUNTIME[0.00051188s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2561' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00017905s] .Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.731, 731, cisco-entity-sensor, subslot 0/0 transceiver 26 Rx Power, SCALE: 0.1, LIMITS: (, -16, -3, ), CURRENT: -2.5, snmp, 731, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '731'] SQL RUNTIME[0.00040007s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '731'] SQL RUNTIME[0.00053596s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2562' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00019097s] .Discover sensor: temperature, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.741, 741, cisco-entity-sensor, subslot 0/0 transceiver 27 Temperature, SCALE: 0.001, LIMITS: (, 0, 70, ), CURRENT: 38.531, snmp, 741, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '741'] SQL RUNTIME[0.00040913s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '741'] SQL RUNTIME[0.00052309s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28002' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00020313s] .Discover sensor: voltage, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.742, 742, cisco-entity-sensor, subslot 0/0 transceiver 27 Supply Voltage, SCALE: 0.0001, LIMITS: (, 3.1, 3.48, ), CURRENT: 3.2948, snmp, 742, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '742'] SQL RUNTIME[0.00516415s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '742'] SQL RUNTIME[0.00048399s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28003' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00015998s] .Discover sensor: current, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.743, 743, cisco-entity-sensor, subslot 0/0 transceiver 27 Bias Current, SCALE: 1.0E-6, LIMITS: (, 0.004, 0.08, ), CURRENT: 0.034682, snmp, 743, Skipped by regexp: /.*subslot\ 0\/[0-9]\ transceiver\ [0-9][0-9]?\ Bias Current/, subslot 0/0 transceiver 27 Bias Current Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.744, 744, cisco-entity-sensor, subslot 0/0 transceiver 27 Tx Power, SCALE: 0.1, LIMITS: (, -6, -1, ), CURRENT: -2.7, snmp, 744, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '744'] SQL RUNTIME[0.00027990s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '744'] SQL RUNTIME[0.00031400s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28004' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00012898s] .Discover sensor: dbm, boi-colo-pe-3, .1.3.6.1.4.1.9.9.91.1.1.1.1.4.745, 745, cisco-entity-sensor, subslot 0/0 transceiver 27 Rx Power, SCALE: 0.1, LIMITS: (, -14.4, -1, ), CURRENT: -1.3, snmp, 745, SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '745'] SQL RUNTIME[0.00028110s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '41' AND `sensor_type` = 'cisco-entity-sensor' AND `sensor_index` = '745'] SQL RUNTIME[0.00034285s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28005' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00013304s] . o CISCO-ENVMON-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENVMON-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' ciscoEnvMonTemperatureStatusEntry] CMD EXITCODE[0] CMD RUNTIME[0.0194s] STDOUT[ ciscoEnvMonTemperatureStatusEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENVMON-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' ciscoEnvMonVoltageStatusEntry] CMD EXITCODE[0] CMD RUNTIME[0.0186s] STDOUT[ ciscoEnvMonVoltageStatusEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENVMON-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' ciscoEnvMonSupplyStatusEntry] CMD EXITCODE[0] CMD RUNTIME[0.0213s] STDOUT[ ciscoEnvMonSupplyStatusEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Fans CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m CISCO-ENVMON-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' ciscoEnvMonFanStatusEntry] CMD EXITCODE[0] CMD RUNTIME[0.0188s] STDOUT[ ciscoEnvMonFanStatusEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] o CISCO-ENTITY-FRU-CONTROL-MIB CISCO-ENTITY-FRU-CONTROL-MIB SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '41' AND `status_type` = 'cisco-envmon-state';] entPhysicalDescr.108 = VADM1: VH entPhysicalDescr.109 = VADM1: AUX1 entPhysicalDescr.110 = VADM1: AUX2 entPhysicalDescr.111 = Temp: CYLON entPhysicalDescr.112 = Temp: BOARD entPhysicalDescr.113 = Temp: Outlet entPhysicalDescr.114 = Temp: CPU entPhysicalDescr.115 = VADM2: VX1 entPhysicalDescr.116 = VADM2: VX2 entPhysicalDescr.117 = VADM2: VX3 entPhysicalDescr.118 = VADM2: VP1 entPhysicalDescr.119 = VADM2: VP2 entPhysicalDescr.120 = VADM2: VP3 entPhysicalDescr.121 = VADM2: VH entPhysicalDescr.122 = Temp: Inlet entPhysicalDescr.130 = CYLON entPhysicalDescr.131 = CPU 0 of module R0 entPhysicalDescr.132 = USB Port entPhysicalDescr.134 = USB Port entPhysicalDescr.136 = Network Management Ethernet entPhysicalDescr.300 = FIXED : 24-port Gig & 4-port Ten Gig SFP Ethernet Interface Module entPhysicalDescr.359 = subslot 0/0 transceiver container 0 entPhysicalDescr.373 = subslot 0/0 transceiver container 1 entPhysicalDescr.374 = GE LX entPhysicalDescr.375 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.377 = subslot 0/0 transceiver 1 Temperature Sensor entPhysicalDescr.378 = subslot 0/0 transceiver 1 Supply Voltage Sensor entPhysicalDescr.379 = subslot 0/0 transceiver 1 Bias Current Sensor entPhysicalDescr.380 = subslot 0/0 transceiver 1 Tx Power Sensor entPhysicalDescr.381 = subslot 0/0 transceiver 1 Rx Power Sensor entPhysicalDescr.387 = subslot 0/0 transceiver container 2 entPhysicalDescr.401 = subslot 0/0 transceiver container 3 entPhysicalDescr.415 = subslot 0/0 transceiver container 4 entPhysicalDescr.429 = subslot 0/0 transceiver container 5 entPhysicalDescr.443 = subslot 0/0 transceiver container 6 entPhysicalDescr.457 = subslot 0/0 transceiver container 7 entPhysicalDescr.471 = subslot 0/0 transceiver container 8 entPhysicalDescr.485 = subslot 0/0 transceiver container 9 entPhysicalDescr.499 = subslot 0/0 transceiver container 10 entPhysicalDescr.513 = subslot 0/0 transceiver container 11 entPhysicalDescr.527 = subslot 0/0 transceiver container 12 entPhysicalDescr.528 = GE LX entPhysicalDescr.529 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.531 = subslot 0/0 transceiver 12 Temperature Sensor entPhysicalDescr.532 = subslot 0/0 transceiver 12 Supply Voltage Sensor entPhysicalDescr.533 = subslot 0/0 transceiver 12 Bias Current Sensor entPhysicalDescr.534 = subslot 0/0 transceiver 12 Tx Power Sensor entPhysicalDescr.535 = subslot 0/0 transceiver 12 Rx Power Sensor entPhysicalDescr.541 = subslot 0/0 transceiver container 13 entPhysicalDescr.555 = subslot 0/0 transceiver container 14 entPhysicalDescr.569 = subslot 0/0 transceiver container 15 entPhysicalDescr.583 = subslot 0/0 transceiver container 16 entPhysicalDescr.597 = subslot 0/0 transceiver container 17 entPhysicalDescr.611 = subslot 0/0 transceiver container 18 entPhysicalDescr.625 = subslot 0/0 transceiver container 19 entPhysicalDescr.639 = subslot 0/0 transceiver container 20 entPhysicalDescr.653 = subslot 0/0 transceiver container 21 entPhysicalDescr.667 = subslot 0/0 transceiver container 22 entPhysicalDescr.668 = GE T entPhysicalDescr.669 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.681 = subslot 0/0 transceiver container 23 entPhysicalDescr.695 = subslot 0/0 transceiver container 24 entPhysicalDescr.696 = SFP+ 10GBASE-LR entPhysicalDescr.697 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.699 = subslot 0/0 transceiver 24 Temperature Sensor entPhysicalDescr.700 = subslot 0/0 transceiver 24 Supply Voltage Sensor entPhysicalDescr.701 = subslot 0/0 transceiver 24 Bias Current Sensor entPhysicalDescr.702 = subslot 0/0 transceiver 24 Tx Power Sensor entPhysicalDescr.703 = subslot 0/0 transceiver 24 Rx Power Sensor entPhysicalDescr.709 = subslot 0/0 transceiver container 25 entPhysicalDescr.710 = SFP+ 10GBASE-LR entPhysicalDescr.711 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.713 = subslot 0/0 transceiver 25 Temperature Sensor entPhysicalDescr.714 = subslot 0/0 transceiver 25 Supply Voltage Sensor entPhysicalDescr.715 = subslot 0/0 transceiver 25 Bias Current Sensor entPhysicalDescr.716 = subslot 0/0 transceiver 25 Tx Power Sensor entPhysicalDescr.717 = subslot 0/0 transceiver 25 Rx Power Sensor entPhysicalDescr.723 = subslot 0/0 transceiver container 26 entPhysicalDescr.724 = SFP+ 10GBASE-ER entPhysicalDescr.725 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.727 = subslot 0/0 transceiver 26 Temperature Sensor entPhysicalDescr.728 = subslot 0/0 transceiver 26 Supply Voltage Sensor entPhysicalDescr.729 = subslot 0/0 transceiver 26 Bias Current Sensor entPhysicalDescr.730 = subslot 0/0 transceiver 26 Tx Power Sensor entPhysicalDescr.731 = subslot 0/0 transceiver 26 Rx Power Sensor entPhysicalDescr.737 = subslot 0/0 transceiver container 27 entPhysicalDescr.738 = SFP+ 10GBASE-LR entPhysicalDescr.739 = 24xGE-4x10GE-FIXED-S entPhysicalDescr.741 = subslot 0/0 transceiver 27 Temperature Sensor entPhysicalDescr.742 = subslot 0/0 transceiver 27 Supply Voltage Sensor entPhysicalDescr.743 = subslot 0/0 transceiver 27 Bias Current Sensor entPhysicalDescr.744 = subslot 0/0 transceiver 27 Tx Power Sensor entPhysicalDescr.745 = subslot 0/0 transceiver 27 Rx Power Sensor ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalName] CMD EXITCODE[0] CMD RUNTIME[0.0834s] STDOUT[ entPhysicalName.1 = Chassis entPhysicalName.2 = slot R0 entPhysicalName.3 = subslot 0/0 entPhysicalName.4 = subslot 0/1 entPhysicalName.5 = Power Supply Bay 0 entPhysicalName.6 = Power Supply Module 0 entPhysicalName.7 = PEM Iout P0/0 entPhysicalName.8 = PEM Vout P0/1 entPhysicalName.9 = PEM Vin P0/2 entPhysicalName.10 = PEM Pin P0/3 entPhysicalName.11 = Temp: Temp 3 P0/4 entPhysicalName.12 = Temp: Temp 2 P0/5 entPhysicalName.25 = Power Supply Bay 1 entPhysicalName.26 = Power Supply Module 1 entPhysicalName.27 = PEM Iout P1/0 entPhysicalName.28 = PEM Vout P1/1 entPhysicalName.29 = PEM Vin P1/2 entPhysicalName.30 = PEM Pin P1/3 entPhysicalName.31 = Temp: Temp 3 P1/4 entPhysicalName.32 = Temp: Temp 2 P1/5 entPhysicalName.45 = Fan Tray Bay 0 entPhysicalName.46 = Fan Tray entPhysicalName.47 = Temp: FC PWM P2/0 entPhysicalName.108 = VADM1: VH R0/7 entPhysicalName.109 = VADM1: AUX1 R0/8 entPhysicalName.110 = VADM1: AUX2 R0/9 entPhysicalName.111 = Temp: CYLON R0/10 entPhysicalName.112 = Temp: BOARD R0/11 entPhysicalName.113 = Temp: Outlet R0/12 entPhysicalName.114 = Temp: CPU R0/13 entPhysicalName.115 = VADM2: VX1 R0/14 entPhysicalName.116 = VADM2: VX2 R0/15 entPhysicalName.117 = VADM2: VX3 R0/16 entPhysicalName.118 = VADM2: VP1 R0/17 entPhysicalName.119 = VADM2: VP2 R0/18 entPhysicalName.120 = VADM2: VP3 R0/19 entPhysicalName.121 = VADM2: VH R0/20 entPhysicalName.122 = Temp: Inlet R0/21 entPhysicalName.130 = CYLON entPhysicalName.131 = cpu R0/0 entPhysicalName.132 = usb R0/0 entPhysicalName.134 = usb R0/1 entPhysicalName.136 = NME R0 entPhysicalName.300 = FIXED IM subslot 0/0 entPhysicalName.359 = subslot 0/0 transceiver container 0 entPhysicalName.373 = subslot 0/0 transceiver container 1 entPhysicalName.374 = subslot 0/0 transceiver 1 entPhysicalName.375 = GigabitEthernet0/0/1 entPhysicalName.377 = subslot 0/0 transceiver 1 Temperature Sensor entPhysicalName.378 = subslot 0/0 transceiver 1 Supply Voltage Sensor entPhysicalName.379 = subslot 0/0 transceiver 1 Bias Current Sensor entPhysicalName.380 = subslot 0/0 transceiver 1 Tx Power Sensor entPhysicalName.381 = subslot 0/0 transceiver 1 Rx Power Sensor entPhysicalName.387 = subslot 0/0 transceiver container 2 entPhysicalName.401 = subslot 0/0 transceiver container 3 entPhysicalName.415 = subslot 0/0 transceiver container 4 entPhysicalName.429 = subslot 0/0 transceiver container 5 entPhysicalName.443 = subslot 0/0 transceiver container 6 entPhysicalName.457 = subslot 0/0 transceiver container 7 entPhysicalName.471 = subslot 0/0 transceiver container 8 entPhysicalName.485 = subslot 0/0 transceiver container 9 entPhysicalName.499 = subslot 0/0 transceiver container 10 entPhysicalName.513 = subslot 0/0 transceiver container 11 entPhysicalName.527 = subslot 0/0 transceiver container 12 entPhysicalName.528 = subslot 0/0 transceiver 12 entPhysicalName.529 = GigabitEthernet0/0/12 entPhysicalName.531 = subslot 0/0 transceiver 12 Temperature Sensor entPhysicalName.532 = subslot 0/0 transceiver 12 Supply Voltage Sensor entPhysicalName.533 = subslot 0/0 transceiver 12 Bias Current Sensor entPhysicalName.534 = subslot 0/0 transceiver 12 Tx Power Sensor entPhysicalName.535 = subslot 0/0 transceiver 12 Rx Power Sensor entPhysicalName.541 = subslot 0/0 transceiver container 13 entPhysicalName.555 = subslot 0/0 transceiver container 14 entPhysicalName.569 = subslot 0/0 transceiver container 15 entPhysicalName.583 = subslot 0/0 transceiver container 16 entPhysicalName.597 = subslot 0/0 transceiver container 17 entPhysicalName.611 = subslot 0/0 transceiver container 18 entPhysicalName.625 = subslot 0/0 transceiver container 19 entPhysicalName.639 = subslot 0/0 transceiver container 20 entPhysicalName.653 = subslot 0/0 transceiver container 21 entPhysicalName.667 = subslot 0/0 transceiver container 22 entPhysicalName.668 = subslot 0/0 transceiver 22 entPhysicalName.669 = GigabitEthernet0/0/22 entPhysicalName.681 = subslot 0/0 transceiver container 23 entPhysicalName.695 = subslot 0/0 transceiver container 24 entPhysicalName.696 = subslot 0/0 transceiver 24 entPhysicalName.697 = TenGigabitEthernet0/0/24 entPhysicalName.699 = subslot 0/0 transceiver 24 Temperature Sensor entPhysicalName.700 = subslot 0/0 transceiver 24 Supply Voltage Sensor entPhysicalName.701 = subslot 0/0 transceiver 24 Bias Current Sensor entPhysicalName.702 = subslot 0/0 transceiver 24 Tx Power Sensor entPhysicalName.703 = subslot 0/0 transceiver 24 Rx Power Sensor entPhysicalName.709 = subslot 0/0 transceiver container 25 entPhysicalName.710 = subslot 0/0 transceiver 25 entPhysicalName.711 = TenGigabitEthernet0/0/25 entPhysicalName.713 = subslot 0/0 transceiver 25 Temperature Sensor entPhysicalName.714 = subslot 0/0 transceiver 25 Supply Voltage Sensor entPhysicalName.715 = subslot 0/0 transceiver 25 Bias Current Sensor entPhysicalName.716 = subslot 0/0 transceiver 25 Tx Power Sensor entPhysicalName.717 = subslot 0/0 transceiver 25 Rx Power Sensor entPhysicalName.723 = subslot 0/0 transceiver container 26 entPhysicalName.724 = subslot 0/0 transceiver 26 entPhysicalName.725 = TenGigabitEthernet0/0/26 entPhysicalName.727 = subslot 0/0 transceiver 26 Temperature Sensor entPhysicalName.728 = subslot 0/0 transceiver 26 Supply Voltage Sensor entPhysicalName.729 = subslot 0/0 transceiver 26 Bias Current Sensor entPhysicalName.730 = subslot 0/0 transceiver 26 Tx Power Sensor entPhysicalName.731 = subslot 0/0 transceiver 26 Rx Power Sensor entPhysicalName.737 = subslot 0/0 transceiver container 27 entPhysicalName.738 = subslot 0/0 transceiver 27 entPhysicalName.739 = TenGigabitEthernet0/0/27 entPhysicalName.741 = subslot 0/0 transceiver 27 Temperature Sensor entPhysicalName.742 = subslot 0/0 transceiver 27 Supply Voltage Sensor entPhysicalName.743 = subslot 0/0 transceiver 27 Bias Current Sensor entPhysicalName.744 = subslot 0/0 transceiver 27 Tx Power Sensor entPhysicalName.745 = subslot 0/0 transceiver 27 Rx Power Sensor ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalClass] CMD EXITCODE[0] CMD RUNTIME[0.0762s] STDOUT[ entPhysicalClass.1 = chassis entPhysicalClass.2 = container entPhysicalClass.3 = container entPhysicalClass.4 = container entPhysicalClass.5 = container entPhysicalClass.6 = powerSupply entPhysicalClass.7 = sensor entPhysicalClass.8 = sensor entPhysicalClass.9 = sensor entPhysicalClass.10 = sensor entPhysicalClass.11 = sensor entPhysicalClass.12 = sensor entPhysicalClass.25 = container entPhysicalClass.26 = powerSupply entPhysicalClass.27 = sensor entPhysicalClass.28 = sensor entPhysicalClass.29 = sensor entPhysicalClass.30 = sensor entPhysicalClass.31 = sensor entPhysicalClass.32 = sensor entPhysicalClass.45 = container entPhysicalClass.46 = fan entPhysicalClass.47 = sensor entPhysicalClass.108 = sensor entPhysicalClass.109 = sensor entPhysicalClass.110 = sensor entPhysicalClass.111 = sensor entPhysicalClass.112 = sensor entPhysicalClass.113 = sensor entPhysicalClass.114 = sensor entPhysicalClass.115 = sensor entPhysicalClass.116 = sensor entPhysicalClass.117 = sensor entPhysicalClass.118 = sensor entPhysicalClass.119 = sensor entPhysicalClass.120 = sensor entPhysicalClass.121 = sensor entPhysicalClass.122 = sensor entPhysicalClass.130 = cpu entPhysicalClass.131 = cpu entPhysicalClass.132 = container entPhysicalClass.134 = container entPhysicalClass.136 = port entPhysicalClass.300 = module entPhysicalClass.359 = container entPhysicalClass.373 = container entPhysicalClass.374 = module entPhysicalClass.375 = port entPhysicalClass.377 = sensor entPhysicalClass.378 = sensor entPhysicalClass.379 = sensor entPhysicalClass.380 = sensor entPhysicalClass.381 = sensor entPhysicalClass.387 = container entPhysicalClass.401 = container entPhysicalClass.415 = container entPhysicalClass.429 = container entPhysicalClass.443 = container entPhysicalClass.457 = container entPhysicalClass.471 = container entPhysicalClass.485 = container entPhysicalClass.499 = container entPhysicalClass.513 = container entPhysicalClass.527 = container entPhysicalClass.528 = module entPhysicalClass.529 = port entPhysicalClass.531 = sensor entPhysicalClass.532 = sensor entPhysicalClass.533 = sensor entPhysicalClass.534 = sensor entPhysicalClass.535 = sensor entPhysicalClass.541 = container entPhysicalClass.555 = container entPhysicalClass.569 = container entPhysicalClass.583 = container entPhysicalClass.597 = container entPhysicalClass.611 = container entPhysicalClass.625 = container entPhysicalClass.639 = container entPhysicalClass.653 = container entPhysicalClass.667 = container entPhysicalClass.668 = module entPhysicalClass.669 = port entPhysicalClass.681 = container entPhysicalClass.695 = container entPhysicalClass.696 = module entPhysicalClass.697 = port entPhysicalClass.699 = sensor entPhysicalClass.700 = sensor entPhysicalClass.701 = sensor entPhysicalClass.702 = sensor entPhysicalClass.703 = sensor entPhysicalClass.709 = container entPhysicalClass.710 = module entPhysicalClass.711 = port entPhysicalClass.713 = sensor entPhysicalClass.714 = sensor entPhysicalClass.715 = sensor entPhysicalClass.716 = sensor entPhysicalClass.717 = sensor entPhysicalClass.723 = container entPhysicalClass.724 = module entPhysicalClass.725 = port entPhysicalClass.727 = sensor entPhysicalClass.728 = sensor entPhysicalClass.729 = sensor entPhysicalClass.730 = sensor entPhysicalClass.731 = sensor entPhysicalClass.737 = container entPhysicalClass.738 = module entPhysicalClass.739 = port entPhysicalClass.741 = sensor entPhysicalClass.742 = sensor entPhysicalClass.743 = sensor entPhysicalClass.744 = sensor entPhysicalClass.745 = sensor ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalContainedIn] CMD EXITCODE[0] CMD RUNTIME[0.0818s] STDOUT[ entPhysicalContainedIn.1 = 0 entPhysicalContainedIn.2 = 1 entPhysicalContainedIn.3 = 1 entPhysicalContainedIn.4 = 1 entPhysicalContainedIn.5 = 1 entPhysicalContainedIn.6 = 5 entPhysicalContainedIn.7 = 6 entPhysicalContainedIn.8 = 6 entPhysicalContainedIn.9 = 6 entPhysicalContainedIn.10 = 6 entPhysicalContainedIn.11 = 6 entPhysicalContainedIn.12 = 6 entPhysicalContainedIn.25 = 1 entPhysicalContainedIn.26 = 25 entPhysicalContainedIn.27 = 26 entPhysicalContainedIn.28 = 26 entPhysicalContainedIn.29 = 26 entPhysicalContainedIn.30 = 26 entPhysicalContainedIn.31 = 26 entPhysicalContainedIn.32 = 26 entPhysicalContainedIn.45 = 1 entPhysicalContainedIn.46 = 45 entPhysicalContainedIn.47 = 46 entPhysicalContainedIn.108 = 100 entPhysicalContainedIn.109 = 100 entPhysicalContainedIn.110 = 100 entPhysicalContainedIn.111 = 100 entPhysicalContainedIn.112 = 100 entPhysicalContainedIn.113 = 100 entPhysicalContainedIn.114 = 100 entPhysicalContainedIn.115 = 100 entPhysicalContainedIn.116 = 100 entPhysicalContainedIn.117 = 100 entPhysicalContainedIn.118 = 100 entPhysicalContainedIn.119 = 100 entPhysicalContainedIn.120 = 100 entPhysicalContainedIn.121 = 100 entPhysicalContainedIn.122 = 100 entPhysicalContainedIn.130 = 100 entPhysicalContainedIn.131 = 100 entPhysicalContainedIn.132 = 100 entPhysicalContainedIn.134 = 100 entPhysicalContainedIn.136 = 100 entPhysicalContainedIn.300 = 3 entPhysicalContainedIn.359 = 300 entPhysicalContainedIn.373 = 300 entPhysicalContainedIn.374 = 373 entPhysicalContainedIn.375 = 374 entPhysicalContainedIn.377 = 374 entPhysicalContainedIn.378 = 374 entPhysicalContainedIn.379 = 374 entPhysicalContainedIn.380 = 374 entPhysicalContainedIn.381 = 374 entPhysicalContainedIn.387 = 300 entPhysicalContainedIn.401 = 300 entPhysicalContainedIn.415 = 300 entPhysicalContainedIn.429 = 300 entPhysicalContainedIn.443 = 300 entPhysicalContainedIn.457 = 300 entPhysicalContainedIn.471 = 300 entPhysicalContainedIn.485 = 300 entPhysicalContainedIn.499 = 300 entPhysicalContainedIn.513 = 300 entPhysicalContainedIn.527 = 300 entPhysicalContainedIn.528 = 527 entPhysicalContainedIn.529 = 528 entPhysicalContainedIn.531 = 528 entPhysicalContainedIn.532 = 528 entPhysicalContainedIn.533 = 528 entPhysicalContainedIn.534 = 528 entPhysicalContainedIn.535 = 528 entPhysicalContainedIn.541 = 300 entPhysicalContainedIn.555 = 300 entPhysicalContainedIn.569 = 300 entPhysicalContainedIn.583 = 300 entPhysicalContainedIn.597 = 300 entPhysicalContainedIn.611 = 300 entPhysicalContainedIn.625 = 300 entPhysicalContainedIn.639 = 300 entPhysicalContainedIn.653 = 300 entPhysicalContainedIn.667 = 300 entPhysicalContainedIn.668 = 667 entPhysicalContainedIn.669 = 668 entPhysicalContainedIn.681 = 300 entPhysicalContainedIn.695 = 300 entPhysicalContainedIn.696 = 695 entPhysicalContainedIn.697 = 696 entPhysicalContainedIn.699 = 696 entPhysicalContainedIn.700 = 696 entPhysicalContainedIn.701 = 696 entPhysicalContainedIn.702 = 696 entPhysicalContainedIn.703 = 696 entPhysicalContainedIn.709 = 300 entPhysicalContainedIn.710 = 709 entPhysicalContainedIn.711 = 710 entPhysicalContainedIn.713 = 710 entPhysicalContainedIn.714 = 710 entPhysicalContainedIn.715 = 710 entPhysicalContainedIn.716 = 710 entPhysicalContainedIn.717 = 710 entPhysicalContainedIn.723 = 300 entPhysicalContainedIn.724 = 723 entPhysicalContainedIn.725 = 724 entPhysicalContainedIn.727 = 724 entPhysicalContainedIn.728 = 724 entPhysicalContainedIn.729 = 724 entPhysicalContainedIn.730 = 724 entPhysicalContainedIn.731 = 724 entPhysicalContainedIn.737 = 300 entPhysicalContainedIn.738 = 737 entPhysicalContainedIn.739 = 738 entPhysicalContainedIn.741 = 738 entPhysicalContainedIn.742 = 738 entPhysicalContainedIn.743 = 738 entPhysicalContainedIn.744 = 738 entPhysicalContainedIn.745 = 738 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'boi-colo-pe-3':'161' entPhysicalParentRelPos] CMD EXITCODE[0] CMD RUNTIME[0.0873s] STDOUT[ entPhysicalParentRelPos.1 = -1 entPhysicalParentRelPos.2 = 6 entPhysicalParentRelPos.3 = 0 entPhysicalParentRelPos.4 = 1 entPhysicalParentRelPos.5 = 11 entPhysicalParentRelPos.6 = 0 entPhysicalParentRelPos.7 = 0 entPhysicalParentRelPos.8 = 1 entPhysicalParentRelPos.9 = 2 entPhysicalParentRelPos.10 = 3 entPhysicalParentRelPos.11 = 4 entPhysicalParentRelPos.12 = 5 entPhysicalParentRelPos.25 = 12 entPhysicalParentRelPos.26 = 0 entPhysicalParentRelPos.27 = 0 entPhysicalParentRelPos.28 = 1 entPhysicalParentRelPos.29 = 2 entPhysicalParentRelPos.30 = 3 entPhysicalParentRelPos.31 = 4 entPhysicalParentRelPos.32 = 5 entPhysicalParentRelPos.45 = 13 entPhysicalParentRelPos.46 = 0 entPhysicalParentRelPos.47 = 0 entPhysicalParentRelPos.401 = 3 entPhysicalParentRelPos.415 = 4 entPhysicalParentRelPos.429 = 5 entPhysicalParentRelPos.443 = 6 entPhysicalParentRelPos.457 = 7 entPhysicalParentRelPos.471 = 8 entPhysicalParentRelPos.485 = 9 entPhysicalParentRelPos.499 = 10 entPhysicalParentRelPos.513 = 11 entPhysicalParentRelPos.527 = 12 entPhysicalParentRelPos.528 = 0 entPhysicalParentRelPos.529 = 0 entPhysicalParentRelPos.531 = 1 entPhysicalParentRelPos.532 = 2 entPhysicalParentRelPos.533 = 3 entPhysicalParentRelPos.534 = 4 entPhysicalParentRelPos.535 = 5 entPhysicalParentRelPos.541 = 13 entPhysicalParentRelPos.555 = 14 entPhysicalParentRelPos.569 = 15 entPhysicalParentRelPos.583 = 16 entPhysicalParentRelPos.597 = 17 entPhysicalParentRelPos.611 = 18 entPhysicalParentRelPos.625 = 19 entPhysicalParentRelPos.639 = 20 entPhysicalParentRelPos.653 = 21 entPhysicalParentRelPos.667 = 22 entPhysicalParentRelPos.668 = 0 entPhysicalParentRelPos.669 = 0 entPhysicalParentRelPos.681 = 23 entPhysicalParentRelPos.695 = 24 entPhysicalParentRelPos.696 = 0 entPhysicalParentRelPos.697 = 0 entPhysicalParentRelPos.699 = 1 entPhysicalParentRelPos.700 = 2 entPhysicalParentRelPos.701 = 3 entPhysicalParentRelPos.702 = 4 entPhysicalParentRelPos.703 = 5 entPhysicalParentRelPos.709 = 25 entPhysicalParentRelPos.710 = 0 entPhysicalParentRelPos.711 = 0 entPhysicalParentRelPos.713 = 1 entPhysicalParentRelPos.714 = 2 entPhysicalParentRelPos.715 = 3 entPhysicalParentRelPos.716 = 4 entPhysicalParentRelPos.717 = 5 entPhysicalParentRelPos.723 = 26 entPhysicalParentRelPos.724 = 0 entPhysicalParentRelPos.725 = 0 entPhysicalParentRelPos.727 = 1 entPhysicalParentRelPos.728 = 2 entPhysicalParentRelPos.729 = 3 entPhysicalParentRelPos.730 = 4 entPhysicalParentRelPos.731 = 5 entPhysicalParentRelPos.737 = 27 entPhysicalParentRelPos.738 = 0 entPhysicalParentRelPos.739 = 0 entPhysicalParentRelPos.741 = 1 entPhysicalParentRelPos.742 = 2 entPhysicalParentRelPos.743 = 3 entPhysicalParentRelPos.744 = 4 entPhysicalParentRelPos.745 = 5 ] SNMP STATUS[TRUE] Discover status: boi-colo-pe-3, .1.3.6.1.4.1.9.9.117.1.1.2.1.2.6, cefcFRUPowerOperStatus.6, PowerOperType, ASR 920 250W DC Power Supply, 2, snmp, , powersupply SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '41' AND `status_type` = 'PowerOperType' AND `status_index` = 'cefcFRUPowerOperStatus.6' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00042081s] SQL[SELECT * FROM `status` WHERE `device_id` = '41' AND `status_type` = 'PowerOperType' AND `status_index` = 'cefcFRUPowerOperStatus.6' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00019288s] .Discover status: boi-colo-pe-3, .1.3.6.1.4.1.9.9.117.1.1.2.1.2.26, cefcFRUPowerOperStatus.26, PowerOperType, ASR 920 250W DC Power Supply, 2, snmp, , powersupply