DEBUG! SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';] SQL RUNTIME[0.00007606s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00008106s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';] SQL RUNTIME[0.00005388s] SQL[SELECT * FROM `config`] SQL RUNTIME[0.00005293s] CMD[/bin/hostname -f]  CMD EXITCODE[0] CMD RUNTIME[0.0032s] STDOUT[ observium.partnersandsimons.com ]  ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 0.16.4.7767 http://www.observium.org  SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver';] SQL RUNTIME[0.00012898s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] SQL RUNTIME[0.00005698s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date';] SQL RUNTIME[0.00005698s] CMD[/opt/observium/scripts/distro]  CMD EXITCODE[0] CMD RUNTIME[0.028s] STDOUT[ Linux|3.16.0-4-amd64|amd64|Debian|8.4 ] CMD[/usr/bin/env python --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0038s] STDOUT[ Python 2.7.9 ] SQL[SELECT version();] SQL RUNTIME[0.00015807s] CMD[/usr/bin/snmpget --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0042s] STDOUT[ NET-SNMP version: 5.7.2.1 ] CMD[/usr/bin/rrdtool --version |head -n1]  CMD EXITCODE[0] CMD RUNTIME[0.0065s] STDOUT[ RRDtool 1.4.8 Copyright 1997-2013 by Tobias Oetiker ] CMD[date "+%:z"]  CMD EXITCODE[0] CMD RUNTIME[0.0028s] STDOUT[ -04:00 ] SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00018311s] CMD[/usr/bin/env apache2 -v | awk '/Server version:/ {print $3}']  CMD EXITCODE[0] CMD RUNTIME[0.0342s] STDOUT[ Apache/2.4.10 ] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00017095s] SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.00027800s] ##### Software versions #####   o OS  Linux 3.16.0-4-amd64 [amd64] (Debian 8.4)  o Apache  2.4.10  o PHP  5.6.19-0+deb8u1 (OPcache: DISABLED)  o Python  2.7.9  o MySQL  5.5.47-0+deb8u1 (extension: mysqli 5.5.47)  o SNMP  NET-SNMP 5.7.2.1  o RRDtool  1.4.8 ##### MySQL mode #####   o MySQL  ##### Charset info #####   o PHP  UTF-8  o MySQL  utf8 ##### Timezones info #####   o Date  Friday, 22-Apr-16 10:18:45 EDT  o PHP  -04:00  o MySQL  -04:00 SQL[SELECT * FROM `alerts_maint` WHERE `maint_start` < '1461334725' AND `maint_end` > '1461334725'] SQL RUNTIME[0.00020599s] ##### Starting polling run at 2016-04-22 10:18:45 #####  SQL[SELECT `device_id` FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'pdu.partnersandsimons.com' ORDER BY `device_id` ASC] SQL RUNTIME[0.00047112s] SQL[SELECT * FROM `devices` WHERE `device_id` = '21'] SQL RUNTIME[0.00022101s] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '21'] SQL RUNTIME[0.00007200s] SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'poller.php' AND `device_id` = '21'] SQL RUNTIME[0.00017500s] CMD[/bin/ps -ww -o pid,ppid,uid,gid,tty,stat,time,lstart,args -p 24471]  CMD EXITCODE[0] CMD RUNTIME[0.0112s] STDOUT[ PID PPID UID GID TT STAT TIME STARTED COMMAND 24471 15696 0 0 pts/0 S+ 00:00:00 Fri Apr 22 10:18:44 2016 php ./poller.php -d -m sensors -h pdu.partnersandsimons.com ] CMD[/bin/ps -ww -o pid,ppid,uid,gid,tty,stat,time,lstart,args -p 15696]  CMD EXITCODE[0] CMD RUNTIME[0.0105s] STDOUT[ PID PPID UID GID TT STAT TIME STARTED COMMAND 15696 15688 0 0 pts/0 Ss 00:00:00 Fri Apr 22 10:12:45 2016 -bash ] SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('24471','poller.php','15696','0','php ./poller.php -d -m sensors -h pdu.partnersandsimons.com','1461334724','21')] SQL RUNTIME[0.00173187s] SQL[SELECT * FROM `alert_tests` WHERE 1] SQL RUNTIME[0.00010991s] Cached 20 alert rules. SQL[SELECT * FROM `alert_table` WHERE `device_id` = '21'] SQL RUNTIME[0.00022984s] ##### pdu.partnersandsimons.com [21] #####   o OS  poweralert  o Last poll duration  3.72 seconds  o Last Polled  2016-04-22 10:18:17  o SNMP Version  v1 CMD[/usr/bin/fping -t 500 -c 1 -q 192.168.3.20 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0041s] STDOUT[ 192.168.3.20 : xmt/rcv/%loss = 1/1/0%, min/avg/max = 0.93/0.93/0.93 ] CMD[/usr/bin/snmpget -v1 -c *** -Pu -OQUst -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu.partnersandsimons.com':'161' sysObjectID.0 sysUpTime.0]  CMD EXITCODE[0] CMD RUNTIME[0.0106s] STDOUT[ sysObjectID.0 = enterprises.850.1 sysUpTime.0 = 36882 ] SNMP STATUS[TRUE]  o Device status  Device is reachable by PING (0.93ms) and SNMP (10.61ms) RRD /opt/observium/rrd/pdu.partnersandsimons.com/status.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/pdu.partnersandsimons.com/status.rrd N:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.06] RRD_STATUS[TRUE]  RRD /opt/observium/rrd/pdu.partnersandsimons.com/ping.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/pdu.partnersandsimons.com/ping.rrd N:0.93] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.06] RRD_STATUS[TRUE]  RRD /opt/observium/rrd/pdu.partnersandsimons.com/ping_snmp.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/pdu.partnersandsimons.com/ping_snmp.rrd N:10.61] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.06] RRD_STATUS[TRUE]  SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '21'] SQL RUNTIME[0.00012302s]  o Modules Enabled  system, os, sensors including: includes/polling/system.inc.php ##### Module Start: system #####  CMD[/usr/bin/snmpget -v1 -c *** -Pu -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu.partnersandsimons.com':'161' sysUpTime.0 sysLocation.0 sysContact.0 sysName.0]  CMD EXITCODE[0] CMD RUNTIME[0.0133s] STDOUT[ sysUpTime.0 = 0:0:06:08.84 sysLocation.0 = 1111 W. 35th St., Chicago, IL 60609 sysContact.0 = www.tripplite.com sysName.0 = pdu.partnersandsimons.com ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -v1 -c *** -Pu -Oqv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu.partnersandsimons.com':'161' sysDescr.0]  CMD EXITCODE[0] CMD RUNTIME[0.0099s] STDOUT[ POWERALERT 12 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -v1 -c *** -Pu -Oqvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu.partnersandsimons.com':'161' sysObjectID.0]  CMD EXITCODE[0] CMD RUNTIME[0.0096s] STDOUT[ .1.3.6.1.4.1.850.1 ] SNMP STATUS[TRUE] Using SNMP Agent sysUpTime (368 sec. => 6m 8s) RRD /opt/observium/rrd/pdu.partnersandsimons.com/uptime.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/pdu.partnersandsimons.com/uptime.rrd N:368] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.11] RRD_STATUS[TRUE]   o Uptime  6m 8s > $uptimes - /opt/observium/poller.php:163 /opt/observium/includes/polling/system.inc.php:188 =============================================== array( [sysUpTime] => int(368) [use] => string(9) "sysUpTime" [uptime] => int(368) [formatted] => string(5) "6m 8s" [message] => string(26) "Using SNMP Agent sysUpTime" [previous] => string(3) "337" [diff] => int(-31) [rebooted] => int(0) ) sysLocation rewritten from '1111 W. 35th St., Chicago, IL 60609' to '25 Drydock Ave Boston MA 02210' by DB override.  o sysObjectID  .1.3.6.1.4.1.850.1  o snmpEngineID   o sysDescr  POWERALERT 12  o sysName  pdu.partnersandsimons.com  o Location  25 Drydock Ave Boston MA 02210 SQL[SELECT * FROM `devices_locations` WHERE `device_id` = '21'] SQL RUNTIME[0.00013900s]  o Module time  0.0519s including: includes/polling/os.inc.php ##### Module Start: os #####  SQL[SELECT * FROM `observium_attribs`] SQL RUNTIME[0.00006795s]  o OS Poller  OS CMD[/usr/bin/snmpget -v1 -c *** -Pu -Ovq -m UPS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu.partnersandsimons.com':'161' upsIdentModel.0]  CMD EXITCODE[0] CMD RUNTIME[0.0693s] STDOUT[ PDUMV15NET ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -v1 -c *** -Pu -Ovq -m TRIPPLITE-MIB -M /opt/observium/mibs 'udp':'pdu.partnersandsimons.com':'161' .1.3.6.1.4.1.850.10.2.2.1.12.1]  CMD EXITCODE[0] CMD RUNTIME[0.0684s] STDOUT[ "" ] SNMP STATUS[FALSE] SNMP ERROR[#999 - Unknown] CMD[/usr/bin/snmpget -v1 -c *** -Pu -Ovq -m TRIPPLITE-MIB -M /opt/observium/mibs 'udp':'pdu.partnersandsimons.com':'161' .1.3.6.1.2.1.33.1.1.5.0]  CMD EXITCODE[0] CMD RUNTIME[0.0677s] STDOUT[ Device 1 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -v1 -c *** -Pu -Ovq -m TRIPPLITE-MIB -M /opt/observium/mibs 'udp':'pdu.partnersandsimons.com':'161' .1.3.6.1.4.1.850.100.1.1.4.0]  CMD EXITCODE[0] CMD RUNTIME[0.0137s] STDOUT[ 2349AY016745600207 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -v1 -c *** -Pu -Ovq -m UPS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu.partnersandsimons.com':'161' upsIdentAgentSoftwareVersion.0]  CMD EXITCODE[0] CMD RUNTIME[0.0648s] STDOUT[ 12.06.0061 ] SNMP STATUS[TRUE]  o Hardware    o Version  12.06.0061  o Features    o Serial  2349AY016745600207  o Asset    o Module time  0.3103s including: includes/polling/sensors.inc.php ##### Module Start: sensors #####  SQL[SELECT COUNT(*) FROM `sensors` WHERE `device_id` = '21' AND `sensor_deleted` = '0';] SQL RUNTIME[0.00014591s]  o Sensor Count  3 SQL[SELECT `sensor_type` FROM `sensors` WHERE `device_id` = '21' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0' GROUP BY `sensor_type`] SQL RUNTIME[0.00007391s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'temperature' AND `device_id` = '21'] SQL RUNTIME[0.00030303s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'humidity' AND `device_id` = '21'] SQL RUNTIME[0.00016999s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'fanspeed' AND `device_id` = '21'] SQL RUNTIME[0.00020909s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'airflow' AND `device_id` = '21'] SQL RUNTIME[0.00017405s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'voltage' AND `device_id` = '21'] SQL RUNTIME[0.00021291s] Checking (snmp) voltage Input Array ( [sensor_id] => 180 [sensor_deleted] => 0 [sensor_class] => voltage [device_id] => 21 [poller_type] => snmp [sensor_oid] => .1.3.6.1.2.1.33.1.3.3.1.3.1 [sensor_mib] => [sensor_object] => [sensor_index] => upsInputEntry.1 [sensor_type] => ups-mib [sensor_descr] => Input [sensor_unit] => [sensor_multiplier] => 1 [sensor_limit] => 1260.4 [sensor_limit_warn] => [sensor_limit_low] => 931.6 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 1095.00000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1461334695 [sensor_last_change] => 1461334610 ) CMD[/usr/bin/snmpget -v1 -c *** -Pu -OUqnv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu.partnersandsimons.com':'161' .1.3.6.1.2.1.33.1.3.3.1.3.1]  CMD EXITCODE[0] CMD RUNTIME[0.1253s] STDOUT[ 1095 ] SNMP STATUS[TRUE] Array ( [sensor_value] => 1095 ) RRD CMD[update /opt/observium/rrd/pdu.partnersandsimons.com/sensor-voltage-ups-mib-upsInputEntry.1.rrd N:1095] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.56] RRD_STATUS[TRUE]  > $data - /opt/observium/includes/polling/sensors.inc.php:47 /opt/observium/includes/alerts.inc.php:57 ==================================================== array( [sensor_value] => int(1095) [sensor_event] => string(2) "ok" [sensor_event_uptime] => int(115) [sensor_status] => string(0) "" ) SQL[UPDATE `sensors-state` set `sensor_value` ='1095',`sensor_event` ='ok',`sensor_status` ='',`sensor_last_change` ='1461334610',`sensor_polled` ='1461334725' WHERE `sensor_id` = '180'] SQL RUNTIME[0.00025201s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'current' AND `device_id` = '21'] SQL RUNTIME[0.00032592s] Checking (snmp) current Output Array ( [sensor_id] => 182 [sensor_deleted] => 0 [sensor_class] => current [device_id] => 21 [poller_type] => snmp [sensor_oid] => .1.3.6.1.2.1.33.1.4.4.1.3.1 [sensor_mib] => [sensor_object] => [sensor_index] => upsOutputEntry.1 [sensor_type] => ups-mib [sensor_descr] => Output [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 0 [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 0.00000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1461334696 [sensor_last_change] => 1461334610 ) CMD[/usr/bin/snmpget -v1 -c *** -Pu -OUqnv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu.partnersandsimons.com':'161' .1.3.6.1.2.1.33.1.4.4.1.3.1]  CMD EXITCODE[0] CMD RUNTIME[0.118s] STDOUT[ 0 ] SNMP STATUS[TRUE] Array ( [sensor_value] => 0 ) RRD CMD[update /opt/observium/rrd/pdu.partnersandsimons.com/sensor-current-ups-mib-upsOutputEntry.1.rrd N:0] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.69] RRD_STATUS[TRUE]  - /opt/observium/includes/polling/sensors.inc.php:47 /opt/observium/includes/alerts.inc.php:57 ================================================ array( [sensor_value] => double(0) [sensor_event] => string(2) "ok" [sensor_event_uptime] => int(115) [sensor_status] => string(0) "" ) SQL[UPDATE `sensors-state` set `sensor_value` ='0',`sensor_event` ='ok',`sensor_status` ='',`sensor_last_change` ='1461334610',`sensor_polled` ='1461334725' WHERE `sensor_id` = '182'] SQL RUNTIME[0.00021887s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'power' AND `device_id` = '21'] SQL RUNTIME[0.00027800s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'apower' AND `device_id` = '21'] SQL RUNTIME[0.00016499s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'rpower' AND `device_id` = '21'] SQL RUNTIME[0.00019884s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'impedance' AND `device_id` = '21'] SQL RUNTIME[0.00016189s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'resistance' AND `device_id` = '21'] SQL RUNTIME[0.00021005s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'frequency' AND `device_id` = '21'] SQL RUNTIME[0.00022006s] Checking (snmp) frequency Input Array ( [sensor_id] => 181 [sensor_deleted] => 0 [sensor_class] => frequency [device_id] => 21 [poller_type] => snmp [sensor_oid] => .1.3.6.1.2.1.33.1.3.3.1.2.1 [sensor_mib] => [sensor_object] => [sensor_index] => upsInputEntry.1 [sensor_type] => ups-mib [sensor_descr] => Input [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 628.95 [sensor_limit_warn] => [sensor_limit_low] => 569.05 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 599.00000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1461334696 [sensor_last_change] => 1461334611 ) CMD[/usr/bin/snmpget -v1 -c *** -Pu -OUqnv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu.partnersandsimons.com':'161' .1.3.6.1.2.1.33.1.3.3.1.2.1]  CMD EXITCODE[0] CMD RUNTIME[0.0906s] STDOUT[ 5990 ] SNMP STATUS[TRUE] Array ( [sensor_value] => 5990 ) RRD CMD[update /opt/observium/rrd/pdu.partnersandsimons.com/sensor-frequency-ups-mib-upsInputEntry.1.rrd N:599] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.79] RRD_STATUS[TRUE]  - /opt/observium/includes/polling/sensors.inc.php:47 /opt/observium/includes/alerts.inc.php:57 ================================================ array( [sensor_value] => double(599) [sensor_event] => string(2) "ok" [sensor_event_uptime] => int(115) [sensor_status] => string(0) "" ) SQL[UPDATE `sensors-state` set `sensor_value` ='599',`sensor_event` ='ok',`sensor_status` ='',`sensor_last_change` ='1461334611',`sensor_polled` ='1461334726' WHERE `sensor_id` = '181'] SQL RUNTIME[0.00025201s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'dbm' AND `device_id` = '21'] SQL RUNTIME[0.00026488s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'snr' AND `device_id` = '21'] SQL RUNTIME[0.00019503s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'capacity' AND `device_id` = '21'] SQL RUNTIME[0.00020289s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'load' AND `device_id` = '21'] SQL RUNTIME[0.00015306s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'runtime' AND `device_id` = '21'] SQL RUNTIME[0.00021911s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'state' AND `device_id` = '21'] SQL RUNTIME[0.00014901s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'waterflow' AND `device_id` = '21'] SQL RUNTIME[0.00015092s] SQL[SELECT * FROM `sensors` LEFT JOIN `sensors-state` USING(`sensor_id`) WHERE `sensor_class` = 'counter' AND `device_id` = '21'] SQL RUNTIME[0.00017500s] Descr Class Type Origin Value Event Last Changed Input voltage ups-mib snmp 1095V ok 2016-04-22 10:16:50 Output current ups-mib snmp 0A ok 2016-04-22 10:16:50 Input frequency ups-mib snmp 599Hz ok 2016-04-22 10:16:51  o Module time  0.3750s ##### pdu.partnersandsimons.com [21] completed poller modules at 2016-04-22 10:18:46 #####   o Graphs [checked]  ping, ping_snmp, uptime, voltage, current, frequency  o Poller time  0.7712 seconds Updating pdu.partnersandsimons.com - > $update_array ======== array( [uptime] => int(368) [last_polled] => array( [0] => string(5) "NOW()" ) [last_polled_timetaken] => double(0.7712) [device_state] => string(124) "a:1:{s:15:"poller_mod_perf";a:3:{s:6:"system";d:0.051900000000000002;s:2:"os";d:0.31030000000000002;s:7:"sensors";d:0.375;}}" ┗ serialized ~ array( [poller_mod_perf] => array( [system] => double(0.0519) [os] => double(0.3103) [sensors] => double(0.375) ) ) ) SQL[UPDATE `devices` set `uptime` ='368',`last_polled` =NOW(),`last_polled_timetaken` ='0.7712',`device_state` ='a:1:{s:15:\"poller_mod_perf\";a:3:{s:6:\"system\";d:0.051900000000000002;s:2:\"os\";d:0.31030000000000002;s:7:\"sensors\";d:0.375;}}' WHERE `device_id` = '21'] SQL RUNTIME[0.01161003s]  o Updated Data  uptime, last_polled, last_polled_timetaken, device_state - /opt/observium/poller.php:163 /opt/observium/includes/alerts.inc.php:57 ====================================== array( [device_status] => string(1) "1" [device_status_type] => string(0) "" [device_ping] => string(4) "0.93" [device_snmp] => string(5) "10.61" [device_uptime] => string(3) "337" [device_rebooted] => int(0) [device_duration_poll] => string(4) "3.72" ) SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"device_status\":\"1\"}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1461334726',`last_ok` ='1461334726' WHERE `alert_table_id` = '216'] SQL RUNTIME[0.00166512s] RRD CMD[update /opt/observium/rrd/pdu.partnersandsimons.com/alert-216.rrd N:1:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.82] RRD_STATUS[TRUE]  SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '24471' AND `process_name` = 'poller.php' AND `device_id` = '21'] SQL RUNTIME[0.00111389s] SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`) VALUES ('poll','pdu.partnersandsimons.com','1461334725.165','0.947','1')] SQL RUNTIME[0.00292301s] ./poller.php: pdu.partnersandsimons.com - 1 devices polled in 0.947 secs ##### Completed polling run at 2016-04-22 10:18:46 #####  NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.  o Devices Polled  1  o Poller Time  0.947 secs  o Memory usage  8.25MB (peak: 8.25MB)  o MySQL Usage  Cell[5/0.002s] Row[7/0.003s] Rows[31/0.013s] Column[0/0s] Update[5/0.015s] Insert[2/0.005s] Delete[1/0.001s]  o RRDTool Usage  update[8/0.009s]