DEBUG! Observium 0.15.6.6430 Poller  CMD[/opt/observium/scripts/distro] EXITCODE[0] RUNTIME[0.0172s] STDOUT[ Linux|3.10.0-229.4.2.el7.x86_64|amd64|CentOS|7.1.1503 ] CMD[/usr/bin/env python --version 2>&1] EXITCODE[0] RUNTIME[0.0051s] STDOUT[ Python 2.7.5 ] SQL[SELECT version()] RUNTIME[0.00031877s] CMD[/usr/bin/snmpget --version 2>&1] EXITCODE[0] RUNTIME[0.0089s] STDOUT[ NET-SNMP version: 5.7.2 ] CMD[/usr/bin/rrdtool --version |head -n1] EXITCODE[0] RUNTIME[0.0097s] STDOUT[ RRDtool 1.4.8 Copyright 1997-2013 by Tobias Oetiker ] Software versions: OS: Linux 3.10.0-229.4.2.el7.x86_64 [amd64] (CentOS 7.1.1503) PHP: 5.4.16 Python: Python 2.7.5 MySQL: 5.5.37-MariaDB-wsrep SNMP: NET-SNMP 5.7.2 RRDtool: 1.4.8  Starting polling run: SQL[SELECT `device_id` FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'printer' ORDER BY `device_id` ASC] RUNTIME[0.00073385s] SQL[SELECT * FROM `devices` WHERE `device_id` = '84'] RUNTIME[0.00037193s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00027704s] SQL[SELECT * FROM `alert_tests` WHERE 1] RUNTIME[0.00022292s] Cached 3 alert rules. SQL[SELECT *,`alert_table`.`alert_table_id` AS `alert_table_id` FROM `alert_table` LEFT JOIN `alert_table-state` ON `alert_table`.`alert_table_id` = `alert_table-state`.`alert_table_id` WHERE `device_id` = '84'] RUNTIME[0.00038600s] printer 84 samsung (printer) CMD[/usr/sbin/fping -t 500 -c 1 -q 192.168.66.14 2>&1] EXITCODE[0] RUNTIME[0.025s] STDOUT[ 192.168.66.14 : xmt/rcv/%loss = 1/1/0%, min/avg/max = 21.2/21.2/21.2 ] SQL[SELECT `version` FROM `dbSchema`;] RUNTIME[0.00027299s] CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUst -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' sysObjectID.0 sysUpTime.0] EXITCODE[0] RUNTIME[0.0411s] STDOUT[ sysObjectID.0 = enterprises.236.11.5.1 sysUpTime.0 = 9150700 ] SNMP_STATUS[TRUE] RRD /opt/observium/rrd/printer/status.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/status.rrd N:1]  stdout[OK u:0.00 s:0.01 r:0.08]  stderr[]] RRD /opt/observium/rrd/printer/ping.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/ping.rrd N:21.2]  stdout[OK u:0.00 s:0.01 r:0.08]  stderr[]] RRD /opt/observium/rrd/printer/ping_snmp.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/ping_snmp.rrd N:43.65]  stdout[OK u:0.00 s:0.01 r:0.08]  stderr[]] SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '84'] RUNTIME[0.00041795s] Module [ unix-agent ] disabled globally. Module [ ipmi ] excluded for device. Module [ junose-atm-vp ] excluded for device. Module [ cisco-ipsec-flow-monitor ] excluded for device. Module [ cisco-remote-access-monitor ] excluded for device. Module [ cisco-cef ] excluded for device. Module [ cisco-sla ] excluded for device. Module [ arista-software-ip-forwarding ] excluded for device. Module [ cipsec-tunnels ] excluded for device. Module [ cisco-cbqos ] excluded for device. Module [ cisco-eigrp ] excluded for device. Module [ netscaler-vsvr ] excluded for device. Module [ aruba-controller ] excluded for device. Module [ cisco-vpdn ] disabled globally. Module [ wmi ] disabled globally. including: includes/polling/system.inc.php CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' sysUpTime.0 sysLocation.0 sysContact.0 sysName.0] EXITCODE[0] RUNTIME[0.0366s] STDOUT[ sysUpTime.0 = 1:1:25:07.00 sysLocation.0 = City sysContact.0 = Admin sysName.0 = SEC0015992B27E9 ] SNMP_STATUS[TRUE] CMD[/usr/bin/snmpget -v2c -c *** -Pu -Oqv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' sysDescr.0] EXITCODE[0] RUNTIME[0.0369s] STDOUT[ Samsung CLX-3170 Series; V1.00.01.07 Apr-21-2008;Engine 1.73.47;NIC V4.01.06(TULIP) 04-16-2008;S/N 148WBAIQ500032D ] SNMP_STATUS[TRUE] CMD[/usr/bin/snmpget -v2c -c *** -Pu -Oqvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' sysObjectID.0] EXITCODE[0] RUNTIME[0.0363s] STDOUT[ .1.3.6.1.4.1.236.11.5.1 ] SNMP_STATUS[TRUE] CMD[/usr/bin/snmpget -v2c -c *** -Pu -Ovqn -m SNMP-FRAMEWORK-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' snmpEngineID.0] EXITCODE[0] RUNTIME[0.0367s] STDOUT[ "00 00 00 3F 00 15 99 2B 27 E9 00 00 " ] SNMP_STATUS[TRUE] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00037980s] CMD[/usr/bin/snmpget -v2c -c *** -Pu -Oqv -m HOST-RESOURCES-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' hrSystemUptime.0] EXITCODE[0] RUNTIME[0.0411s] STDOUT[ 1:1:25:07.00 ] SNMP_STATUS[TRUE] Using SNMP Agent hrSystemUptime (91507 sec. => 1 day, 1h 25m 7s) RRD /opt/observium/rrd/printer/uptime.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/uptime.rrd N:91507]  stdout[OK u:0.00 s:0.01 r:0.28]  stderr[]] Uptime: 1 day, 1h 25m 7s Array ( [sysUpTime] => 91507 [hrSystemUptime] => 91507 [use] => hrSystemUptime [uptime] => 91507 [formatted] => 1 day, 1h 25m 7s [message] => Using SNMP Agent hrSystemUptime [previous] => 91444 [diff] => -63 [rebooted] => 0 ) SQL[SELECT * FROM `devices_locations` WHERE `device_id` = '84'] RUNTIME[0.00039601s] Module [ system ] time: 0.2021s including: includes/polling/os.inc.php CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQv -M /opt/observium/mibs 'udp':'printer':'161' HOST-RESOURCES-MIB::hrDeviceDescr.1] EXITCODE[0] RUNTIME[0.0644s] STDOUT[ Samsung CLX-3170 Series; V1.00.01.07 Apr-21-2008, V4.01.06(T ] SNMP_STATUS[TRUE] CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQv -M /opt/observium/mibs 'udp':'printer':'161' Printer-MIB::prtMarkerMarkTech.1.1] EXITCODE[0] RUNTIME[0.0666s] STDOUT[ electrophotographicLaser ] SNMP_STATUS[TRUE] CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQv -M /opt/observium/mibs 'udp':'printer':'161' Printer-MIB::prtGeneralSerialNumber.1] EXITCODE[0] RUNTIME[0.068s] STDOUT[ "148WBAIQ500032D " ] SNMP_STATUS[TRUE] Hardware: CLX-3170 Version: Features: electrophotographicLaser Serial: 148WBAIQ500032D Asset: Module [ os ] time: 0.2055s including: includes/polling/sensors.inc.php SQL[SELECT COUNT(*) FROM `sensors` WHERE `device_id` = '84' AND `sensor_deleted` = '0';] RUNTIME[0.00048494s] Module [ sensors ] time: 0.0012s including: includes/polling/status.inc.php SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '84' AND `status_deleted` = '0';] RUNTIME[0.00025797s] Module [ status ] time: 0.0008s including: includes/polling/processors.inc.php SQL[SELECT `processors`.*, `processors-state`.processor_usage, `processors-state`.processor_polled FROM `processors` LEFT JOIN `processors-state` ON `processors`.processor_id = `processors-state`.processor_id WHERE `device_id` = '84'] RUNTIME[0.00032806s] Processor Samsung CHORUS3 400 MHz CMD[/usr/bin/snmpget -v2c -c *** -Pu -OUQnv -M /opt/observium/mibs 'udp':'printer':'161' .1.3.6.1.2.1.25.3.3.1.2.2] EXITCODE[0] RUNTIME[0.0635s] STDOUT[ 0 ] SNMP_STATUS[TRUE] RRD /opt/observium/rrd/printer/processor-hr-2.rrd already exists - no need to create. 0% RRD[cmd[update /opt/observium/rrd/printer/processor-hr-2.rrd N:0]  stdout[OK u:0.00 s:0.01 r:0.56]  stderr[]] SQL[UPDATE `processors-state` set `processor_usage` ='0',`processor_polled` ='1433858094' WHERE `processor_id` = '586'] RUNTIME[0.00027609s] Checking alerts Array ( [processor_usage] => 0 ) Processor Average CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' hrDevice] EXITCODE[0] RUNTIME[0.1352s] STDOUT[ hrDeviceIndex.1 = 1 hrDeviceIndex.2 = 2 hrDeviceIndex.3 = 3 hrDeviceIndex.4 = 4 hrDeviceIndex.5 = 5 hrDeviceIndex.6 = 6 hrDeviceIndex.7 = 7 hrDeviceType.1 = hrDevicePrinter hrDeviceType.2 = hrDeviceProcessor hrDeviceType.3 = hrDeviceNetwork hrDeviceType.4 = hrDeviceNonVolatileMemory hrDeviceType.5 = hrDeviceUnknown hrDeviceType.6 = hrDeviceUnknown hrDeviceType.7 = hrDeviceUnknown hrDeviceDescr.1 = Samsung CLX-3170 Series; V1.00.01.07 Apr-21-2008, V4.01.06(T hrDeviceDescr.2 = Samsung CHORUS3 400 MHz hrDeviceDescr.3 = Embedded Ethernet Controller 10/100 Mbps, RJ45 hrDeviceDescr.4 = Random Access Memory 128MB hrDeviceDescr.5 = Universal Serial Bus 2.0 hrDeviceDescr.6 = Copier up to 16 cpm in A4 black hrDeviceDescr.7 = Scanner hrDeviceID.1 = enterprises.236.11.5.1 hrDeviceID.2 = zeroDotZero hrDeviceID.3 = zeroDotZero hrDeviceID.4 = zeroDotZero hrDeviceID.5 = zeroDotZero hrDeviceID.6 = zeroDotZero hrDeviceID.7 = zeroDotZero hrDeviceStatus.1 = running hrDeviceStatus.2 = running hrDeviceStatus.3 = running hrDeviceStatus.4 = running hrDeviceStatus.5 = running hrDeviceStatus.6 = running hrDeviceStatus.7 = running hrDeviceErrors.1 = 0 hrDeviceErrors.2 = 0 hrDeviceErrors.3 = 0 hrDeviceErrors.4 = 0 hrDeviceErrors.5 = 0 hrDeviceErrors.6 = 0 hrDeviceErrors.7 = 0 hrProcessorFrwID.2 = zeroDotZero hrProcessorLoad.2 = 0 hrNetworkIfIndex.3 = 1 hrPrinterStatus.1 = idle hrPrinterDetectedErrorState.1 = "00 00 " ] SNMP_STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' hrProcessorLoad] EXITCODE[0] RUNTIME[0.0406s] STDOUT[ hrProcessorLoad.2 = 0 ] SNMP_STATUS[TRUE] RRD /opt/observium/rrd/printer/processor-hr-average-1.rrd already exists - no need to create. 0% RRD[cmd[update /opt/observium/rrd/printer/processor-hr-average-1.rrd N:0]  stdout[OK u:0.00 s:0.01 r:0.74]  stderr[]] SQL[UPDATE `processors-state` set `processor_usage` ='0',`processor_polled` ='1433858095' WHERE `processor_id` = '587'] RUNTIME[0.00023103s] Checking alerts Array ( [processor_usage] => 0 ) Module [ processors ] time: 0.252s including: includes/polling/mempools.inc.php SQL[SELECT *, `mempools`.mempool_id as mempool_id FROM `mempools` LEFT JOIN `mempools-state` ON `mempools`.mempool_id = `mempools-state`.mempool_id WHERE `device_id` = '84'] RUNTIME[0.00049090s] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' hrStorageEntry] EXITCODE[0] RUNTIME[0.0401s] STDOUT[ hrStorageIndex.1 = 1 hrStorageType.1 = hrStorageRam hrStorageDescr.1 = RAM hrStorageAllocationUnits.1 = 1024 hrStorageSize.1 = 131072 hrStorageUsed.1 = 29584 hrStorageAllocationFailures.1 = 0 ] SNMP_STATUS[TRUE] Mempool RAM: 22.57% RRD /opt/observium/rrd/printer/mempool-host-resources-mib-1.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/mempool-host-resources-mib-1.rrd N:30294016:103923712]  stdout[OK u:0.00 s:0.01 r:0.79]  stderr[]] SQL[UPDATE `mempools-state` set `mempool_polled` ='1433858095',`mempool_used` ='30294016',`mempool_perc` ='22.57',`mempool_free` ='103923712',`mempool_total` ='134217728' WHERE `mempool_id` = '374'] RUNTIME[0.00027609s] Checking alerts Array ( [mempool_perc] => 22.57 [mempool_free] => 103923712 [mempool_used] => 30294016 ) Module [ mempools ] time: 0.0463s including: includes/polling/storage.inc.php SQL[SELECT `storage`.*, `storage-state`.storage_polled FROM `storage` LEFT JOIN `storage-state` ON `storage`.storage_id = `storage-state`.storage_id WHERE `device_id` = '84'] RUNTIME[0.00037003s] Module [ storage ] time: 0.0012s including: includes/polling/netstats.inc.php Netstats: CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' ipInReceives.0 ipOutRequests.0] EXITCODE[0] RUNTIME[0.0423s] STDOUT[ ipInReceives.0 = 219422 ipOutRequests.0 = 171811 ] SNMP_STATUS[TRUE] CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' ipForwDatagrams.0 ipInDelivers.0 ipInDiscards.0 ipOutDiscards.0 ipOutNoRoutes.0 ipReasmReqds.0 ipReasmOKs.0 ipReasmFails.0 ipFragOKs.0 ipFragFails.0 ipFragCreates.0 ipInUnknownProtos.0 ipInHdrErrors.0 ipInAddrErrors.0] EXITCODE[0] RUNTIME[0.0428s] STDOUT[ ipForwDatagrams.0 = 0 ipInDelivers.0 = 219424 ipInDiscards.0 = 0 ipOutDiscards.0 = 0 ipOutNoRoutes.0 = 0 ipReasmReqds.0 = 0 ipReasmOKs.0 = 0 ipReasmFails.0 = 0 ipFragOKs.0 = 0 ipFragFails.0 = 0 ipFragCreates.0 = 0 ipInUnknownProtos.0 = 4 ipInHdrErrors.0 = 0 ipInAddrErrors.0 = 0 ] SNMP_STATUS[TRUE] Ip RRD /opt/observium/rrd/printer/netstats-ip.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/netstats-ip.rrd N:0:219424:219422:171811:0:0:0:0:0:0:0:0:0:4:0:0]  stdout[OK u:0.00 s:0.01 r:0.88]  stderr[]] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' icmp] EXITCODE[0] RUNTIME[0.0909s] STDOUT[ icmpInMsgs.0 = 307 icmpInErrors.0 = 0 icmpInDestUnreachs.0 = 0 icmpInTimeExcds.0 = 0 icmpInParmProbs.0 = 0 icmpInSrcQuenchs.0 = 0 icmpInRedirects.0 = 0 icmpInEchos.0 = 307 icmpInEchoReps.0 = 0 icmpInTimestamps.0 = 0 icmpInTimestampReps.0 = 0 icmpInAddrMasks.0 = 0 icmpInAddrMaskReps.0 = 0 icmpOutMsgs.0 = 307 icmpOutErrors.0 = 0 icmpOutDestUnreachs.0 = 0 icmpOutTimeExcds.0 = 0 icmpOutParmProbs.0 = 0 icmpOutSrcQuenchs.0 = 0 icmpOutRedirects.0 = 0 icmpOutEchos.0 = 0 icmpOutEchoReps.0 = 307 icmpOutTimestamps.0 = 0 icmpOutTimestampReps.0 = 0 icmpOutAddrMasks.0 = 0 icmpOutAddrMaskReps.0 = 0 ] SNMP_STATUS[TRUE] Icmp RRD /opt/observium/rrd/printer/netstats-icmp.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/netstats-icmp.rrd N:307:307:0:0:307:0:0:307:0:0:0:0:0:0:0:0:0:0:0:0:0:0:0:0:0:0]  stdout[OK u:0.00 s:0.01 r:0.98]  stderr[]] CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUs -m TCP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' tcpInSegs.0 tcpOutSegs.0] EXITCODE[0] RUNTIME[0.0377s] STDOUT[ tcpInSegs.0 = 130433 tcpOutSegs.0 = 135458 ] SNMP_STATUS[TRUE] CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUs -m TCP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' tcpActiveOpens.0 tcpPassiveOpens.0 tcpAttemptFails.0 tcpEstabResets.0 tcpCurrEstab.0 tcpRetransSegs.0 tcpInErrs.0 tcpOutRsts.0] EXITCODE[0] RUNTIME[0.038s] STDOUT[ tcpActiveOpens.0 = 13323 tcpPassiveOpens.0 = 13438 tcpAttemptFails.0 = 8 tcpEstabResets.0 = 114 tcpCurrEstab.0 = 2 tcpRetransSegs.0 = 6 tcpInErrs.0 = 0 tcpOutRsts.0 = 0 ] SNMP_STATUS[TRUE] TCP RRD /opt/observium/rrd/printer/netstats-tcp.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/netstats-tcp.rrd N:13323:13438:8:114:2:130433:135458:6:0:0]  stdout[OK u:0.00 s:0.01 r:1.06]  stderr[]] CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUs -m UDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' udpInDatagrams.0 udpOutDatagrams.0] EXITCODE[0] RUNTIME[0.0387s] STDOUT[ udpInDatagrams.0 = 88688 udpOutDatagrams.0 = 36045 ] SNMP_STATUS[TRUE] CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUs -m UDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' udpInErrors.0 udpNoPorts.0] EXITCODE[0] RUNTIME[0.0367s] STDOUT[ udpInErrors.0 = 0 udpNoPorts.0 = 0 ] SNMP_STATUS[TRUE] UDP RRD /opt/observium/rrd/printer/netstats-udp.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/netstats-udp.rrd N:88688:36045:0:0]  stdout[OK u:0.00 s:0.01 r:1.14]  stderr[]] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' snmp] EXITCODE[0] RUNTIME[0.0866s] STDOUT[ snmpInPkts.0 = 22267 snmpOutPkts.0 = 22250 snmpInBadVersions.0 = 0 snmpInBadCommunityNames.0 = 0 snmpInBadCommunityUses.0 = 0 snmpInASNParseErrs.0 = 0 snmpInTooBigs.0 = 0 snmpInNoSuchNames.0 = 0 snmpInBadValues.0 = 0 snmpInReadOnlys.0 = 0 snmpInGenErrs.0 = 0 snmpInTotalReqVars.0 = 109619 snmpInTotalSetVars.0 = 0 snmpInGetRequests.0 = 10392 snmpInGetNexts.0 = 2753 snmpInSetRequests.0 = 0 snmpInGetResponses.0 = 0 snmpInTraps.0 = 0 snmpOutTooBigs.0 = 0 snmpOutNoSuchNames.0 = 0 snmpOutBadValues.0 = 0 snmpOutGenErrs.0 = 0 snmpOutGetRequests.0 = 0 snmpOutGetNexts.0 = 0 snmpOutSetRequests.0 = 0 snmpOutGetResponses.0 = 22252 snmpOutTraps.0 = 0 snmpEnableAuthenTraps.0 = 0 ] SNMP_STATUS[TRUE] SNMP RRD /opt/observium/rrd/printer/netstats-snmp.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/netstats-snmp.rrd N:22267:22250:0:0:0:0:0:0:0:0:0:109619:0:10392:2753:0:0:0:0:0:0:0:0:0:0:22252:0:U:U]  stdout[OK u:0.00 s:0.01 r:1.23]  stderr[]] Module [ netstats ] time: 0.4393s including: includes/polling/hr-mib.inc.php CMD[/usr/bin/snmpget -v2c -c *** -Pu -OUQs -m HOST-RESOURCES-MIB -M /opt/observium/mibs 'udp':'printer':'161' hrSystemProcesses.0 hrSystemNumUsers.0] EXITCODE[0] RUNTIME[0.0408s] STDOUT[ hrSystemProcesses.0 = 0 hrSystemNumUsers.0 = 0 ] SNMP_STATUS[TRUE] HR Stats:RRD /opt/observium/rrd/printer/hr_processes.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/hr_processes.rrd N:0]  stdout[OK u:0.00 s:0.01 r:1.28]  stderr[]] ProcessesRRD /opt/observium/rrd/printer/hr_users.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/hr_users.rrd N:0]  stdout[OK u:0.00 s:0.01 r:1.28]  stderr[]] Users Module [ hr-mib ] time: 0.0465s including: includes/polling/ucd-mib.inc.php CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' systemStats] EXITCODE[0] RUNTIME[0.0612s] STDOUT[ systemStats = No Such Object available on this agent at this OID ] SNMP_STATUS[FALSE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' mem] EXITCODE[0] RUNTIME[0.0717s] STDOUT[ memory = No Such Object available on this agent at this OID ] SNMP_STATUS[FALSE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' laLoadInt] EXITCODE[0] RUNTIME[0.0709s] STDOUT[ laLoadInt = No Such Object available on this agent at this OID ] SNMP_STATUS[FALSE] Module [ ucd-mib ] time: 0.2101s including: includes/polling/ipSystemStats.inc.php Polling IP-MIB ipSystemStats CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m IP-MIB -M /opt/observium/mibs 'udp':'printer':'161' ipSystemStats] EXITCODE[0] RUNTIME[0.0713s] STDOUT[ ipSystemStatsTable = No Such Object available on this agent at this OID ] SNMP_STATUS[FALSE] Module [ ipSystemStats ] time: 0.0736s including: includes/polling/ports.inc.php Caching Oids: ifEntry CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' ifEntry] EXITCODE[0] RUNTIME[0.1632s] STDOUT[ ifIndex.1 = 1 ifIndex.6 = 6 ifDescr.1 = Embedded Ethernet Controller, 10/100 Mbps, v1.0, UTP RJ-45, connector A1, 100 full duplex ifDescr.6 = Software Loopback interface ifType.1 = ethernetCsmacd ifType.6 = softwareLoopback ifMtu.1 = 1500 ifMtu.6 = 1536 ifSpeed.1 = 100000000 ifSpeed.6 = 10000 ifPhysAddress.1 = 69:7a:0:0:0:0 ifPhysAddress.6 = 69:7a:0:0:0:0 ifAdminStatus.1 = up ifAdminStatus.6 = up ifOperStatus.1 = up ifOperStatus.6 = up ifLastChange.1 = 0:0:00:00.00 ifLastChange.6 = 0:0:00:00.00 ifInOctets.1 = 24439659 ifInOctets.6 = 26306938 ifInUcastPkts.1 = 87345 ifInUcastPkts.6 = 133148 ifInNUcastPkts.1 = 0 ifInNUcastPkts.6 = 0 ifInDiscards.1 = 0 ifInDiscards.6 = 0 ifInErrors.1 = 0 ifInErrors.6 = 0 ifInUnknownProtos.1 = 20 ifInUnknownProtos.6 = 0 ifOutOctets.1 = 16564387 ifOutOctets.6 = 26306938 ifOutUcastPkts.1 = 14230 ifOutUcastPkts.6 = 133148 ifOutNUcastPkts.1 = 37782 ifOutNUcastPkts.6 = 0 ifOutDiscards.1 = 0 ifOutDiscards.6 = 0 ifOutErrors.1 = 0 ifOutErrors.6 = 0 ifOutQLen.1 = 0 ifOutQLen.6 = 0 ifSpecific.1 = zeroDotZero ifSpecific.6 = zeroDotZero ] SNMP_STATUS[TRUE] ifXEntry CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' ifXEntry] EXITCODE[0] RUNTIME[0.0644s] STDOUT[ ifXEntry = No Such Object available on this agent at this OID ] SNMP_STATUS[FALSE] dot3StatsDuplexStatus CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m EtherLike-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' dot3StatsDuplexStatus] EXITCODE[0] RUNTIME[0.0608s] STDOUT[ dot3StatsDuplexStatus = No Such Object available on this agent at this OID ] SNMP_STATUS[FALSE] SQL[SELECT COUNT(*) FROM `ports` WHERE `device_id` = '84' AND `ifType` = 'adsl'] RUNTIME[0.00049806s] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' dot1qPortVlanTable] EXITCODE[0] RUNTIME[0.0765s] STDOUT[ dot1qPortVlanTable = No Such Object available on this agent at this OID ] SNMP_STATUS[FALSE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' dot1qVlanStaticUntaggedPorts] EXITCODE[0] RUNTIME[0.0755s] STDOUT[ dot1qVlanStaticUntaggedPorts = No Such Object available on this agent at this OID ] SNMP_STATUS[FALSE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m SMON-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' portCopyStatus] EXITCODE[0] RUNTIME[0.0724s] STDOUT[ portCopyStatus = No Such Object available on this agent at this OID ] SNMP_STATUS[FALSE] SQL[SELECT *, I.`port_id` AS `port_id` FROM `ports` AS I LEFT JOIN `ports-state` AS S ON I.`port_id` = S.`port_id` WHERE `device_id` = '84'] RUNTIME[0.00058913s] Port Embedded Ethernet Controller, 10/100 Mbps, v1.0, UTP RJ-45, connector A1, 100 full duplex(1) VLAN == [ifPhysAddress] 2bba00000000 -> 697a00000000 SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`) VALUES ('84','1059','port',NOW(),'6','Interface changed: [ifPhysAddress] 2bba00000000 -> 697a00000000')] RUNTIME[0.00028896s] ifInOctets (21580 B) 342.53968253968 Bps 63 secs ifOutOctets (14069 B) 223.31746031746 Bps 63 secs ifInErrors (0 B) 0 Bps 63 secs ifOutErrors (0 B) 0 Bps 63 secs ifInUcastPkts (108 B) 1.7142857142857 Bps 63 secs ifOutUcastPkts (8 B) 0.12698412698413 Bps 63 secs bps(2.74kbps/1.79kbps)bytes(21.0kB/13.7kB)pkts(1.71pps/0.13pps) SQL[SELECT * FROM `devices` WHERE `device_id` = '84'] RUNTIME[0.00034499s] SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '84'] RUNTIME[0.00030208s] RRD /opt/observium/rrd/printer/port-1.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/port-1.rrd N:24439659:16564387:0:0:87345:14230:0:37782:0:0:20:U:U:U:U]  stdout[OK u:0.00 s:0.01 r:2.10]  stderr[]] Checking alerts Array ( [ifInOctets_rate] => 342.53968253968 [ifInOctets_delta] => 21580 [ifOutOctets_rate] => 223.31746031746 [ifOutOctets_delta] => 14069 [ifInErrors_rate] => 0 [ifInErrors_delta] => 0 [ifOutErrors_rate] => 0 [ifOutErrors_delta] => 0 [ifInUcastPkts_rate] => 1.7142857142857 [ifInUcastPkts_delta] => 108 [ifOutUcastPkts_rate] => 0.12698412698413 [ifOutUcastPkts_delta] => 8 [ifInBits_rate] => 2740 [ifOutBits_rate] => 1787 [ifOperStatus] => up [ifAdminStatus] => up [ifMtu] => 1500 [ifSpeed] => 100000000 [ifInOctets_perc] => 0 [ifOutOctets_perc] => 0 [rx_ave_pktsize] => 199.81481481481 [tx_ave_pktsize] => 1758.625 ) SQL[UPDATE `ports` set `ifPhysAddress` ='697a00000000' WHERE `port_id` = '1059'] RUNTIME[0.00063109s] PORT updated rows=1 SQL[UPDATE `ports-state` set `poll_time` ='1433858096',`poll_period` ='63',`ifInOctets` ='24439659',`ifInOctets_rate` ='342.53968253968',`ifInOctets_delta` ='21580',`ifOutOctets` ='16564387',`ifOutOctets_rate` ='223.31746031746',`ifOutOctets_delta` ='14069',`ifInErrors` ='0',`ifInErrors_rate` ='0',`ifInErrors_delta` ='0',`ifOutErrors` ='0',`ifOutErrors_rate` ='0',`ifOutErrors_delta` ='0',`ifInUcastPkts` ='87345',`ifInUcastPkts_rate` ='1.7142857142857',`ifInUcastPkts_delta` ='108',`ifOutUcastPkts` ='14230',`ifOutUcastPkts_rate` ='0.12698412698413',`ifOutUcastPkts_delta` ='8',`ifInOctets_perc` ='0',`ifOutOctets_perc` ='0',`ifOctets_rate` ='565.85714285714',`ifUcastPkts_rate` ='1.8412698412698',`ifErrors_rate` ='0' WHERE `port_id` = '1059'] RUNTIME[0.00027418s] STATE updated rows=1 Port Software Loopback interface(6) VLAN == [ifPhysAddress] 2bba00000000 -> 697a00000000 SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`) VALUES ('84','1060','port',NOW(),'6','Interface changed: [ifPhysAddress] 2bba00000000 -> 697a00000000')] RUNTIME[0.00018907s] ifInOctets (15808 B) 250.92063492063 Bps 63 secs ifOutOctets (15808 B) 250.92063492063 Bps 63 secs ifInErrors (0 B) 0 Bps 63 secs ifOutErrors (0 B) 0 Bps 63 secs ifInUcastPkts (80 B) 1.2698412698413 Bps 63 secs ifOutUcastPkts (80 B) 1.2698412698413 Bps 63 secs bps(2.01kbps/2.01kbps)bytes(15.4kB/15.4kB)pkts(1.27pps/1.27pps)RRD /opt/observium/rrd/printer/port-6.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/port-6.rrd N:26306938:26306938:0:0:133148:133148:0:0:0:0:0:U:U:U:U]  stdout[OK u:0.00 s:0.01 r:2.10]  stderr[]] Checking alerts Array ( [ifInOctets_rate] => 250.92063492063 [ifInOctets_delta] => 15808 [ifOutOctets_rate] => 250.92063492063 [ifOutOctets_delta] => 15808 [ifInErrors_rate] => 0 [ifInErrors_delta] => 0 [ifOutErrors_rate] => 0 [ifOutErrors_delta] => 0 [ifInUcastPkts_rate] => 1.2698412698413 [ifInUcastPkts_delta] => 80 [ifOutUcastPkts_rate] => 1.2698412698413 [ifOutUcastPkts_delta] => 80 [ifInBits_rate] => 2007 [ifOutBits_rate] => 2007 [ifOperStatus] => up [ifAdminStatus] => up [ifMtu] => 1536 [ifSpeed] => 10000 [ifInOctets_perc] => 20 [ifOutOctets_perc] => 20 [rx_ave_pktsize] => 197.6 [tx_ave_pktsize] => 197.6 ) SQL[UPDATE `ports` set `ifPhysAddress` ='697a00000000' WHERE `port_id` = '1060'] RUNTIME[0.00063396s] PORT updated rows=1 SQL[UPDATE `ports-state` set `poll_time` ='1433858096',`poll_period` ='63',`ifInOctets` ='26306938',`ifInOctets_rate` ='250.92063492063',`ifInOctets_delta` ='15808',`ifOutOctets` ='26306938',`ifOutOctets_rate` ='250.92063492063',`ifOutOctets_delta` ='15808',`ifInErrors` ='0',`ifInErrors_rate` ='0',`ifInErrors_delta` ='0',`ifOutErrors` ='0',`ifOutErrors_rate` ='0',`ifOutErrors_delta` ='0',`ifInUcastPkts` ='133148',`ifInUcastPkts_rate` ='1.2698412698413',`ifInUcastPkts_delta` ='80',`ifOutUcastPkts` ='133148',`ifOutUcastPkts_rate` ='1.2698412698413',`ifOutUcastPkts_delta` ='80',`ifInOctets_perc` ='20',`ifOutOctets_perc` ='20',`ifOctets_rate` ='501.84126984127',`ifUcastPkts_rate` ='2.5396825396825',`ifErrors_rate` ='0' WHERE `port_id` = '1060'] RUNTIME[0.00021911s] STATE updated rows=1 Module [ ports ] time: 0.5442s including: includes/polling/bgp-peers.inc.php Module [ bgp-peers ] time: 0.0011s including: includes/polling/toner.inc.php SQL[SELECT * FROM `toner` WHERE `device_id` = '84'] RUNTIME[0.00029182s] Checking toner Cyan Color Cartridge... CMD[/usr/bin/snmpget -v2c -c *** -Pu -OUqnv -M /opt/observium/mibs 'udp':'printer':'161' .1.3.6.1.2.1.43.11.1.1.9.1.1] EXITCODE[0] RUNTIME[0.0629s] STDOUT[ 24 ] SNMP_STATUS[TRUE] RRD /opt/observium/rrd/printer/toner-1.rrd already exists - no need to create. 24 % RRD[cmd[update /opt/observium/rrd/printer/toner-1.rrd N:24]  stdout[OK u:0.00 s:0.01 r:2.18]  stderr[]] SQL[UPDATE `toner` set `toner_current` ='24',`toner_capacity` ='100' WHERE `toner_id` = '4'] RUNTIME[0.00085092s] Checking alerts Array ( [toner_current] => 24 ) Checking toner Magenta Color Cartridge... CMD[/usr/bin/snmpget -v2c -c *** -Pu -OUqnv -M /opt/observium/mibs 'udp':'printer':'161' .1.3.6.1.2.1.43.11.1.1.9.1.2] EXITCODE[0] RUNTIME[0.0654s] STDOUT[ 24 ] SNMP_STATUS[TRUE] RRD /opt/observium/rrd/printer/toner-2.rrd already exists - no need to create. 24 % RRD[cmd[update /opt/observium/rrd/printer/toner-2.rrd N:24]  stdout[OK u:0.00 s:0.01 r:2.25]  stderr[]] SQL[UPDATE `toner` set `toner_current` ='24',`toner_capacity` ='100' WHERE `toner_id` = '5'] RUNTIME[0.00062108s] Checking alerts Array ( [toner_current] => 24 ) Checking toner Yellow Color Cartridge... Wrong process status! Try fix.. CMD[/usr/bin/snmpget -v2c -c *** -Pu -OUqnv -M /opt/observium/mibs 'udp':'printer':'161' .1.3.6.1.2.1.43.11.1.1.9.1.3] EXITCODE[0] RUNTIME[0.0631s] STDOUT[ 24 ] SNMP_STATUS[TRUE] RRD /opt/observium/rrd/printer/toner-3.rrd already exists - no need to create. 24 % RRD[cmd[update /opt/observium/rrd/printer/toner-3.rrd N:24]  stdout[OK u:0.00 s:0.01 r:2.31]  stderr[]] SQL[UPDATE `toner` set `toner_current` ='24',`toner_capacity` ='100' WHERE `toner_id` = '6'] RUNTIME[0.00743508s] Checking alerts Array ( [toner_current] => 24 ) Checking toner Black Color Cartridge... CMD[/usr/bin/snmpget -v2c -c *** -Pu -OUqnv -M /opt/observium/mibs 'udp':'printer':'161' .1.3.6.1.2.1.43.11.1.1.9.1.4] EXITCODE[0] RUNTIME[0.0642s] STDOUT[ 49 ] SNMP_STATUS[TRUE] RRD /opt/observium/rrd/printer/toner-4.rrd already exists - no need to create. 49 % RRD[cmd[update /opt/observium/rrd/printer/toner-4.rrd N:49]  stdout[OK u:0.00 s:0.01 r:2.39]  stderr[]] SQL[UPDATE `toner` set `toner_current` ='49',`toner_capacity` ='100' WHERE `toner_id` = '7'] RUNTIME[0.00083303s] Checking alerts Array ( [toner_current] => 49 ) SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '84' AND `attrib_type` = 'pagecount_oid'] RUNTIME[0.00040412s] Checking page count... CMD[/usr/bin/snmpget -v2c -c *** -Pu -OUqnv -M /opt/observium/mibs 'udp':'printer':'161' 1.3.6.1.2.1.43.10.2.1.4.1.1] EXITCODE[0] RUNTIME[0.0647s] STDOUT[ 2282 ] SNMP_STATUS[TRUE] RRD /opt/observium/rrd/printer/pagecount.rrd already exists - no need to create. SQL[SELECT COUNT(*) FROM devices_attribs WHERE `device_id` = '84' AND `attrib_type` = 'pagecounter'] RUNTIME[0.00040603s] SQL[UPDATE `devices_attribs` set `attrib_value` ='2282' WHERE device_id='84' and attrib_type='pagecounter'] RUNTIME[0.00020099s] RRD[cmd[update /opt/observium/rrd/printer/pagecount.rrd N:2282]  stdout[OK u:0.00 s:0.01 r:2.46]  stderr[]] 2282 SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '84' AND `attrib_type` = 'imagingdrum_oid'] RUNTIME[0.00029397s] SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '84' AND `attrib_type` = 'imagingdrum_c_oid'] RUNTIME[0.00020218s] SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '84' AND `attrib_type` = 'imagingdrum_m_oid'] RUNTIME[0.00017500s] SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '84' AND `attrib_type` = 'imagingdrum_y_oid'] RUNTIME[0.00027704s] SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '84' AND `attrib_type` = 'imagingdrum_k_oid'] RUNTIME[0.00024104s] SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '84' AND `attrib_type` = 'wastebox_oid'] RUNTIME[0.00025582s] SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '84' AND `attrib_type` = 'fuser_oid'] RUNTIME[0.00018287s] SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '84' AND `attrib_type` = 'transferroller_oid'] RUNTIME[0.00017691s] Module [ toner ] time: 0.3601s including: includes/polling/ucd-diskio.inc.php SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '84'] RUNTIME[0.00019693s] Module [ ucd-diskio ] time: 0.0008s including: includes/polling/wifi.inc.php Module [ wifi ] time: 0.0003s including: includes/polling/ospf.inc.php OSPF: Processes: SQL[SELECT * FROM `ospf_instances` WHERE `device_id` = '84'] RUNTIME[0.00030899s] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OQUs -m OSPF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'printer':'161' ospfGeneralGroup] EXITCODE[0] RUNTIME[0.0634s] STDOUT[ ospfGeneralGroup = No Such Object available on this agent at this OID ] SNMP_STATUS[FALSE] Areas: SQL[SELECT * FROM `ospf_areas` WHERE `device_id` = '84'] RUNTIME[0.00043511s] poll Ports: SQL[SELECT * FROM `ospf_ports` WHERE `device_id` = '84'] RUNTIME[0.00026107s] Neighbours: SQL[SELECT * FROM `ospf_nbrs` WHERE `device_id` = '84'] RUNTIME[0.00019312s] Module [ ospf ] time: 0.069s including: includes/polling/mac-accounting.inc.php Mac Accounting: SQL[SELECT *, `mac_accounting`.`ma_id` as `ma_id` FROM `mac_accounting` LEFT JOIN `mac_accounting-state` ON `mac_accounting`.ma_id = `mac_accounting-state`.ma_id WHERE `device_id` = '84'] RUNTIME[0.00032616s] Module [ mac-accounting ] time: 0.0015s including: includes/polling/loadbalancer.inc.php Load balancer: SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00035119s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00023818s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00021386s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00017905s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00019217s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00019693s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00024414s] Module [ loadbalancer ] time: 0.005s including: includes/polling/entity-physical.inc.php Module [ entity-physical ] time: 0.0003s including: includes/polling/applications.inc.php SQL[SELECT * FROM `applications` WHERE `device_id` = '84'] RUNTIME[0.00027800s] Module [ applications ] time: 0.0009s including: includes/polling/fdb-table.inc.php FDB Tables SQL[SELECT `ifIndex`,`port_id`,`ifDescr` FROM `ports` WHERE `device_id` = '84'] RUNTIME[0.00025606s] SQL[SELECT * FROM `vlans_fdb` WHERE `device_id` = '84'] RUNTIME[0.00022507s] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pu -OqsX -m Q-BRIDGE-MIB -M /opt/observium/mibs 'udp':'printer':'161' dot1qTpFdbEntry] EXITCODE[0] RUNTIME[0.0759s] STDOUT[ dot1qTpFdbEntry No Such Object available on this agent at this OID ] SNMP_STATUS[FALSE] Module [ fdb-table ] time: 0.0798s including: includes/polling/graphs.inc.php Graphs SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00036192s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00025797s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00020790s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00020289s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00020003s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00019693s] SQL[SELECT * FROM `devices_attribs` WHERE `device_id` = '84'] RUNTIME[0.00018215s] Module [ graphs ] time: 0.0049s Graphs [checked]: ping, ping_snmp, uptime, processor, mempool, netstat_ip, netstat_ip_frag, netstat_icmp, netstat_icmp_info, netstat_tcp_stats, netstat_tcp_segments, netstat_tcp_currestab, netstat_udp_datagrams, netstat_udp_errors, netstat_snmp_stats, netstat_snmp_packets, hr_processes, hr_users, bits, toner, fdb_count, poller_perf Polled in 2.6358 seconds SQL[INSERT INTO `devices_perftimes` (`device_id`,`operation`,`start`,`duration`) VALUES ('84','poll','1433858094.2911','2.6358230113983')] RUNTIME[0.00014997s] RRD /opt/observium/rrd/printer/perf-poller.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/perf-poller.rrd N:2.6358]  stdout[OK u:0.00 s:0.01 r:2.63]  stderr[]] Updating printer - Array ( [uptime] => 91507 [last_polled] => Array ( [0] => NOW() ) [last_polled_timetaken] => 2.6358 [device_state] => a:1:{s:15:"poller_mod_perf";a:23:{s:6:"system";s:6:"0.2021";s:2:"os";s:6:"0.2055";s:7:"sensors";s:6:"0.0012";s:6:"status";s:6:"0.0008";s:10:"processors";s:6:"0.2520";s:8:"mempools";s:6:"0.0463";s:7:"storage";s:6:"0.0012";s:8:"netstats";s:6:"0.4393";s:6:"hr-mib";s:6:"0.0465";s:7:"ucd-mib";s:6:"0.2101";s:13:"ipSystemStats";s:6:"0.0736";s:5:"ports";s:6:"0.5442";s:9:"bgp-peers";s:6:"0.0011";s:5:"toner";s:6:"0.3601";s:10:"ucd-diskio";s:6:"0.0008";s:4:"wifi";s:6:"0.0003";s:4:"ospf";s:6:"0.0690";s:14:"mac-accounting";s:6:"0.0015";s:12:"loadbalancer";s:6:"0.0050";s:15:"entity-physical";s:6:"0.0003";s:12:"applications";s:6:"0.0009";s:9:"fdb-table";s:6:"0.0798";s:6:"graphs";s:6:"0.0049";}} ) SQL[UPDATE `devices` set `uptime` ='91507',`last_polled` =NOW(),`last_polled_timetaken` ='2.6358',`device_state` ='a:1:{s:15:\"poller_mod_perf\";a:23:{s:6:\"system\";s:6:\"0.2021\";s:2:\"os\";s:6:\"0.2055\";s:7:\"sensors\";s:6:\"0.0012\";s:6:\"status\";s:6:\"0.0008\";s:10:\"processors\";s:6:\"0.2520\";s:8:\"mempools\";s:6:\"0.0463\";s:7:\"storage\";s:6:\"0.0012\";s:8:\"netstats\";s:6:\"0.4393\";s:6:\"hr-mib\";s:6:\"0.0465\";s:7:\"ucd-mib\";s:6:\"0.2101\";s:13:\"ipSystemStats\";s:6:\"0.0736\";s:5:\"ports\";s:6:\"0.5442\";s:9:\"bgp-peers\";s:6:\"0.0011\";s:5:\"toner\";s:6:\"0.3601\";s:10:\"ucd-diskio\";s:6:\"0.0008\";s:4:\"wifi\";s:6:\"0.0003\";s:4:\"ospf\";s:6:\"0.0690\";s:14:\"mac-accounting\";s:6:\"0.0015\";s:12:\"loadbalancer\";s:6:\"0.0050\";s:15:\"entity-physical\";s:6:\"0.0003\";s:12:\"applications\";s:6:\"0.0009\";s:9:\"fdb-table\";s:6:\"0.0798\";s:6:\"graphs\";s:6:\"0.0049\";}}' WHERE `device_id` = '84'] RUNTIME[0.00077581s] UPDATED! Checking alerts Array ( [device_status] => 1 [device_status_type] => [device_ping] => 21.2 [device_snmp] => 43.65 [device_uptime] => 91444 [device_rebooted] => 0 [device_duration_poll] => 2.57 ) Checking alert 1 associated by 1 Testing: device_status equals 0 (value: 1) OK Checks OK. SQL[UPDATE `alert_table-state` set `state` ='{\"metrics\":{\"device_status\":\"1\"}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1433858096' WHERE `alert_table_id` = '249'] RUNTIME[0.00020599s] RRD /opt/observium/rrd/printer/alert-249.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/alert-249.rrd N:1:1]  stdout[OK u:0.00 s:0.01 r:2.64]  stderr[]] Checking alert 3 associated by 3 Testing: device_rebooted equals 1 (value: 0) OK Checks OK. SQL[UPDATE `alert_table-state` set `state` ='{\"metrics\":{\"device_rebooted\":0}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1433858096' WHERE `alert_table_id` = '348'] RUNTIME[0.00020099s] RRD /opt/observium/rrd/printer/alert-348.rrd already exists - no need to create. RRD[cmd[update /opt/observium/rrd/printer/alert-348.rrd N:1:1]  stdout[OK u:0.00 s:0.01 r:2.64]  stderr[]] SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`) VALUES ('poll','printer','1433858094.2365','2.700','1')] RUNTIME[0.00017500s] ./poller.php: printer - 1 devices polled in 2.700 secs NOTE, $config['snmp']['hide_auth'] sets as TRUE, snmp community and snmp v3 auth hidden from debug output. Memory usage: 5.25MB (peak: 5.25MB) MySQL: Cell[6/0s] Row[12/0.01s] Rows[26/0.02s] Column[0/0s] Update[15/0.02s] Insert[4/0s] Delete[0/0s]